Speak to a sourcing specialist
sales13@apterpower.com

6GK7443-5DX05-0XE0

PROFIBUS Communications Processor
Siemens 6GK7443-5DX05-0XE0
Siemens 6GK7443-5DX05-0XE0
Siemens 6GK7443-5DX05-0XE0
Siemens 6GK7443-5DX05-0XE0
Siemens 6GK7443-5DX05-0XE0
Siemens 6GK7443-5DX05-0XE0
Product image is representative; revision or series may vary. Contact us to request a specific version.

Product Describe:

Siemens 6GK7443-5DX05-0XE0 connects an S7-400 station to PROFIBUS DP and supported controller communication services.
  • Manufacturer part number
    6GK7443-5DX05-0XE0
  • Shipping
    Swift global dispatch
  • Condition
    New, original product
  • Shipping size (est.)
    2.4cm x 22.4cm x 29cm
  • Country of Origin
    Germany
Get a quick price for 6GK7443-5DX05-0XE0
E-mail *
Mobile
Company
Content *
Quantity *
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)
For more information on how your data is processed and stored by Apterpower please read our privacy policy

What happens after you enquire

  • 0

    Review your reference

    Send the complete 6GK7443-5DX05-0XE0 reference, label photographs and required quantity, together with the installed system position.

  • 1

    Confirm the offer

    Review the offered 6GK7443-5DX05-0XE0 execution, condition, included connection hardware and applicable documentation.

  • 2

    Arrange dispatch

    Confirm quantity, dispatch date and delivery details for 6GK7443-5DX05-0XE0 in the quotation.

  • Match the complete marking

    Match the complete Siemens 6GK7443-5DX05-0XE0 marking, hardware execution and connection arrangement to the installed position before approving the order.

  • Check the offered item before ordering

    Request clear photographs of the offered 6GK7443-5DX05-0XE0 and ask your maintenance team to compare its markings and interfaces with the installed equipment and applicable Siemens instructions.

Technical specifications for 6GK7443-5DX05-0XE0

  • Manufacturer:
    Siemens
  • Product Category:
    PLC Systems
  • Spare Part Number:
    6GK7443-5DX05-0XE0
  • Weight:
    0.68 kg
  • Tariff Code:
    8537101190
  • PROFIBUS data rate:
    9.6 kbit/s to 12 Mbit/s
  • Bus connector:
    9-pin Sub-D; RS485
  • Backplane supply:
    5 V DC; +/-5%
  • Typical current:
    0.6 A
  • Power loss:
    3 W
  • DP devices:
    Up to 125
  • DP input address space:
    4096 bytes total
  • DP output address space:
    4096 bytes total
  • Per-device I/O:
    244 bytes input; 244 bytes output
  • DPV1 services:
    Supported
  • Operating temperature:
    0-60 degrees C

Information

Overview Downloads Applications / Compatibility Product Precautions
  • Siemens 6GK7443-5DX05-0XE0 coordinates cyclic DP exchange and supported engineering services without making every network device interchangeable.
Network role: DP master and controller communication
Engineering services: Supported acyclic access and routing
Resource planning: Shared CP and station communication capacity
The CP443-5 Extended can serve distributed DP devices while supporting additional communication services. Station addresses, configured modules and process-data lengths must agree with the physical network before cyclic exchange is accepted.

A network can satisfy its baud-rate setting yet still have poor electrical integrity. Cable topology, termination and segment loading remain system-level responsibilities. Diagnose intermittent communication with the actual segment arrangement rather than increasing retries without cause.

DPV1 and routing services enable additional engineering functions when the participating devices and software support them. Their availability does not imply that every connected slave accepts every acyclic service or that all changes can occur without process interruption.
Controller platform reference: SIMATIC S7-400. Use the applicable installation instructions and approved design.
The original technical excerpt supports 6GK7443-5DX05-0XE0 configuration review. The separate Apter Power field guide organizes practical diagnostic checks. Installation topics include: record the dp station map and process lengths, inspect segment termination and topology, restore cp configuration and supported services.
Original manufacturer pages retain their technical context. Use the Apter Power guide with the applicable manufacturer instructions and approved installation design.
System and supply context: 6GK7443-5DX05-0XE0 belongs to the SIMATIC S7-400 installation described by the technical reference. Connected equipment and accessories must be included explicitly in the configured assembly.

Application scope: The following uses describe supported engineering roles; they do not establish interchangeability with another model or remove application-specific validation.
Prepare Siemens 6GK7443-5DX05-0XE0 for its configured installation using these checks.
Record the DP station map and process lengths

Record the PROFIBUS segment, station addresses, DP devices and any configured engineering or S7 services using the CP. Preserve the hardware configuration and per-device input/output mapping. Assess cyclic I/O allocation separately from other connection resources before modifying the station.

Inspect segment termination and topology

Review the segment topology, cable route and termination arrangement under the approved PROFIBUS installation rules. Identify which equipment provides power to terminating elements where applicable. Keep affected distributed I/O controlled while disconnecting a network boundary or changing station configuration.

Restore CP configuration and supported services

Restore the configured CP and device parameters, keeping station addresses unique. Check total I/O space and each device allocation against the supported limits. Confirm that the intended DP services and device configuration agree at both the master project and field equipment.

Test cyclic data separately from routing

Observe master and device diagnostics and compare actual input changes and controlled output commands with the configured addresses. Test the required acyclic service independently when the application uses it. A successful engineering connection must not replace verification of cyclic production data.

Confirm station resources and network recovery

Review normal operation after removing test connections and restoring the process. Record the final station map and any changed device parameters with the controller project. Monitor representative updates under the intended bus loading and preserve the approved fallback behavior for loss of a device.

Keep the technical scope explicit

Use the exact hardware execution with the supported system configuration and installation conditions.

Alternative Names

Siemens 6GK7443-5DX05-0XE0

Technical notes

Configuration baseline: Keep the installed SIMATIC S7-400 arrangement aligned with the complete 6GK7443-5DX05-0XE0 reference and its assigned system role.

Acceptance boundary: Compare the electrical or communication response with the intended application outcome before releasing maintenance controls.

Technical reference: Siemens CP443-5 Extended, C79000-G8976-C162-10. Use the exact hardware execution with the supported system configuration and installation conditions.

FAQ View All FAQ

  • Why can 6GK7443-5DX05-0XE0 recognize a DP device but reject its process data?
    The detected station identity may not match the configured module layout or data length. Compare the device configuration and diagnostic details before changing addresses. Recognition alone is not proof of valid cyclic data exchange.
  • How should intermittent faults on 6GK7443-5DX05-0XE0 be investigated at high baud rates?
    Inspect termination, connectors, cable topology and segment limits under the actual network conditions. Correlate failures with the affected segment and operating load. Lowering the baud rate can mask an electrical problem without correcting it.
  • Does DPV1 support in 6GK7443-5DX05-0XE0 guarantee every slave supports acyclic access?
    No. The target device and its configuration must support the requested service. Verify device capabilities and service responses before treating a rejected parameter request as a CP failure.
  • Why must total station resources be checked before adding another 6GK7443-5DX05-0XE0?
    The permitted CP arrangement depends on other communication processors and their roles. Count DP masters and PROFINET IO controllers in the complete station, and assess shared resources rather than using one standalone maximum.
  • What distinguishes a routing failure from a cyclic DP fault on 6GK7443-5DX05-0XE0?
    Cyclic I/O can remain healthy while a routing path or engineering address is wrong. Check the intended route, participating device support and tool configuration separately from cyclic diagnostics. Avoid disrupting a healthy process bus to troubleshoot an engineering-only path.
  • How should a replacement slave behind 6GK7443-5DX05-0XE0 be accepted?
    Verify the station address, configured modules, data lengths and parameter set, then test the affected process values and outputs. A matching product family or an extinguished fault lamp does not prove the application mapping is correct.
  • Can communication connection limits of 6GK7443-5DX05-0XE0 be treated independently of DP operation?
    No. Mixed-mode capacity differs with and without DP, and services share resources. Review the installed connection mix and engineering access requirements before expanding traffic.
  • What is required before changing the PROFIBUS rate on 6GK7443-5DX05-0XE0?
    Confirm that every participant and segment supports the selected rate and that cable lengths and termination remain valid. Plan an approved network outage and verify all stations afterward; a local rate change is not an isolated module setting.
SPEAK TO OUR TEAM
Let’s find the right solution for you.
Send us the part number, quantity and delivery destination. Our team will help confirm availability and lead time.
  • Whatsapp: +86 18030235313

    Send us a message.
  • sales13@apterpower.com

    Complete our online form.
  • +86 18030235313

    Speak to our team in your native language.