Match the complete marking
Match the complete Siemens 6ES7153-2BA82-0XB0 marking and installed configuration. Confirm complete IM reference, product version, firmware and partner identity where redundant.
-
Check the offered item before ordering
Request available label and connector photos. Have your maintenance team compare the offered 6ES7153-2BA82-0XB0 with the installed equipment and applicable Siemens documents.
Technical specifications for 6ES7153-2BA82-0XB0
-
Manufacturer:Siemens
-
Product Category:PLC Systems
-
Spare Part Number:6ES7153-2BA82-0XB0
-
Weight:0.24 kg
-
Tariff Code:8537101190
-
Fieldbus:PROFIBUS DP
-
Station role:DP slave
-
Maximum attached modules:12 for BAx2 arrangement
-
High-accuracy timestamp limit:8 input modules at 1 ms accuracy
-
Outdoor operating range:-25 to +60 °C with suitable station components
-
Redundant interface count:2 identical compatible IM modules
-
24 V supply current, product version 01:600 mA maximum
-
24 V supply current, product version 02:620 mA maximum
Information
- Siemens 6ES7153-2BA82-0XB0 coordinates configured I/O and diagnostics between the field station and DP master. Redundant interface arrangements, module replacement and timestamp functions must be engineered as complete station features.
Station services: Configuration, process data and diagnostics
Architecture options: Redundancy and active-backplane arrangements
The BAx2 interface supports an expanded module count, but high-accuracy timestamp use imposes a lower module limit. Capacity planning must therefore include enabled functions rather than counting physical slots alone. Configure the correct interface and I/O identities in the controller project.
Redundant IM 153-2 modules must have matching order numbers and matching product or firmware versions. Review both partners during replacement and test the switchover and channel behavior under the approved process conditions. A healthy individual interface does not prove the redundant system is ready.
6ES7153-2BA82-0XB0 Original Technical Excerpt
Siemens ET 200M Operating Instructions, EWA-4NEB780600602-08 and IM 153-2 HF Product Information. Selected original pages retain the relevant technical context. PDF · 10 pages.6ES7153-2BA82-0XB0 Installation & Verification Guide
Apter Power installation workbook covering capture station and partner identity, qualify the outdoor assembly, restore network configuration, testing and handover. PDF · 5 pages.
Application scope: The applications describe the complete signal or control path. Confirm the intended function and interface; accessories are supplied only when itemized.
Outdoor distributed I/O
Connect suitably qualified ET 200M components to PROFIBUS DP.Redundant station interface
Use matching partners in the engineered redundant arrangement.Timestamped event acquisition
Collect events within the configured synchronization and module limits.Serviceable I/O architecture
Coordinate a correctly configured active-backplane station.
Record the DP address, I/O order, enabled functions and both interface versions where redundant. Identify the required process response before separating a partner or fieldbus connection.
Inspect interface, active bus, rail and I/O suitability for the environment. Review supply capacity against the actual product version and attached loads. Do not assume standard modules inherit the interface rating.
Match the physical address and module order to the master project. Reconnect the intended bus and termination arrangement and review configuration diagnostics before accepting data exchange.
Verify individual I/O and any timestamp function, observing its module limit. For redundancy, test the approved switchover and confirm the process response rather than checking only partner LEDs.
Remove maintenance substitutions after all affected channels and station diagnostics are accepted. Retain partner versions, address plan and the tested fault-response results.
Retain the final tested settings, physical connection and accepted process response for 6ES7153-2BA82-0XB0.
Alternative Names
Technical notes
Environment boundary: Expanded conditions require compatible interface, bus and I/O hardware; they do not transfer automatically from the interface to the station.
Version-sensitive power: Use the supply-current requirement for the actual product version and include all attached station loads.
Redundancy acceptance: Match both partners and test the configured switchover, diagnostics and channel response.
FAQ View All FAQ
-
Can 6ES7153-2BA82-0XB0 make standard attached I/O suitable for outdoor conditions?No. Each bus and I/O component must suit the expanded environmental conditions. Qualify the complete station arrangement.
-
Why may the usable module count be lower with 6ES7153-2BA82-0XB0 timestamping enabled?The high-accuracy 1 ms timestamp arrangement is limited to eight input modules. Review function-specific limits before using the general twelve-module capacity.
-
Can a different firmware partner be mixed with 6ES7153-2BA82-0XB0 in a redundant station?Redundant interfaces must meet the identical-order and product/firmware-version requirement. Review both partners before replacement.
-
Why should product version be checked when budgeting supply for 6ES7153-2BA82-0XB0?The maximum supply-current figure differs between product versions 01 and 02. Size the station supply using the actual hardware execution.
-
What proves redundancy after a replacement involving 6ES7153-2BA82-0XB0?Check partner compatibility, station diagnostics and a controlled switchover with the required I/O behavior. A normal LED on one module is insufficient.
-
What must be retained before changing the DP address of 6ES7153-2BA82-0XB0?Record the controller configuration, station identity and network address plan. Update the corresponding master project so that the physical and configured station agree.
-
Does active-backplane support on 6ES7153-2BA82-0XB0 permit unrestricted online maintenance?No. The attached module, configuration and process response must permit the specific operation. Follow the approved station maintenance procedure.
-
How should a station that communicates but has wrong channel values with 6ES7153-2BA82-0XB0 be investigated?Compare configured module order, parameterization and process-data mapping with the physical station, then test the affected channels individually.
Supporting new and legacy automation
-
Please try to be as accurate as possible with your search.
-
We can quote you on 1000s of specialist parts, even if they are not listed on our website.
-
We can't find any results for “”.
Related cases and sourcing guidance
View all case studiesYou May Also Like
Product Browsing History
-
Whatsapp: +86 18030235313
Send us a message. -
sales13@apterpower.com
Complete our online form. -
+86 18030235313
Speak to our team in your native language.