Match the complete marking
Match the complete Siemens 6ES7305-1BA80-0AA0 marking, hardware execution and connection arrangement to the installed position before approving the order.
-
Check the offered item before ordering
Request clear photographs of the offered 6ES7305-1BA80-0AA0 and ask your maintenance team to compare its markings and interfaces with the installed equipment and applicable Siemens instructions.
Technical specifications for 6ES7305-1BA80-0AA0
-
Manufacturer:Siemens
-
Product Category:PLC Systems
-
Spare Part Number:6ES7305-1BA80-0AA0
-
Weight:0.5 kg
-
Tariff Code:8537101190
-
Rated input range:24-110 V DC
-
Permissible input range:16.8-138 V DC
-
Rated output:24 V DC
-
Rated output current:2 A
-
Nominal output power:48 W
-
Output adjustment:Not adjustable
-
Maximum residual ripple:150 mV
-
Maximum output-voltage peak:240 mV
-
Typical efficiency:75%
-
Typical power loss:16 W
-
Minimum buffering:10 ms at rated input and rated load
Information
- Siemens 6ES7305-1BA80-0AA0 provides the control-power boundary between the DC source and consuming modules, where startup demand and wiring drop must be assessed together.
Startup behavior: Controlled output rise without overshoot
Service distinction: Source condition, supply output and downstream drop
Its regulated output and short-duration overload behavior serve different operating conditions. Sustained load must fit the continuous rating and ambient conditions, while a temporary starting pulse cannot be used as a continuous-current allowance.
The green output-status indicator helps identify the supply state, but downstream voltage also depends on distribution wiring. Check the voltage at the consuming module during its actual startup and steady-state loading.
6ES7305-1BA80-0AA0 Original Technical Excerpt
The original technical excerpt supports 6ES7305-1BA80-0AA0 configuration review. The separate Apter Power field guide organizes practical diagnostic checks. PDF · 1 page.6ES7305-1BA80-0AA0 Installation & Verification Guide
Apter Power engineering guide for the installed signal, power or communication path and controlled acceptance. PDF · 5 pages.
Application scope: The following uses describe supported engineering roles; they do not establish interchangeability with another model or remove application-specific validation.
DC-fed control cabinets
Power an S7-300 installation from a suitable DC source.Outdoor control assemblies
Apply the product within its specified environmental design.Control-power restoration
Restore feeder protection and the original output distribution.Load-transient diagnosis
Separate startup demand from sustained overload.
Identify the DC distribution source, feeder protection and polarity at the supply input. List the continuous and startup demands of connected loads, separating electronics power from any unrelated field circuit. Confirm that the actual source range and transient environment suit this DC-input supply before reconnection.
Isolate the input and affected output circuits using the approved procedure. Inspect supply and return conductors, distribution protection and terminal condition. Preserve the circuit layout so a replacement does not accidentally parallel supplies or combine previously separate control-power branches.
Restore input polarity and the regulated output distribution. Measure output at the supply and at the consuming module under the intended load. Compare both readings during startup as well as steady operation; the supply indicator is only one part of the verification.
Assess starting pulses separately from continuous demand and ambient conditions. Where a permitted higher-load condition is used, verify all associated source and thermal restrictions rather than treating a short-duration current response as an unrestricted rating. Review the loads if repeated starts cause voltage collapse.
Observe the connected control system through its authorized restart sequence and confirm no consumer resets unexpectedly. Remove temporary meters and restore covers before normal service. Retain the source range, load schedule and consumer voltage observations so future additions can be assessed against an established baseline.
Use the exact hardware execution with the supported system configuration and installation conditions.
Alternative Names
Technical notes
Configuration baseline: Keep the installed SIMATIC S7-300 arrangement aligned with the complete 6ES7305-1BA80-0AA0 reference and its assigned system role.
Acceptance boundary: Compare the electrical or communication response with the intended application outcome before releasing maintenance controls.
Technical reference: Siemens PS305 data sheet, 6ES7305-1BA80-0AA0. Use the exact hardware execution with the supported system configuration and installation conditions.
FAQ View All FAQ
-
Why must an AC feeder never be substituted at 6ES7305-1BA80-0AA0?This PS305 execution is designed for DC input. Confirm source type and polarity at the disconnected feeder before installation. A voltage magnitude that appears similar does not make an AC source acceptable.
-
How can a startup failure behind 6ES7305-1BA80-0AA0 be distinguished from a continuous overload?Measure the output during startup and after the load settles. Compare transient demand with the permitted overload behavior and steady demand with the continuous rating. Repeated starts without recovery can create a different thermal condition from one isolated pulse.
-
Why can 6ES7305-1BA80-0AA0 indicate 24 V OK while a remote module resets?The indicator describes the supply output, not voltage at the remote load. Measure at the consuming device during the reset and inspect distribution resistance and returns. A long or loose connection can produce local undervoltage.
-
Does the overload pulse capability of 6ES7305-1BA80-0AA0 justify a larger continuous load?No. Temporary excess-current capability has a limited duration and purpose. Size the sustained load to the continuous output and temperature conditions, and assess inrush separately. Otherwise a system may start successfully but fail after warming.
-
What matters when selecting feeder protection for 6ES7305-1BA80-0AA0?Use a protective device suitable for the actual DC source and its fault current, and account for inrush. An AC-only breaking rating is not automatically valid on DC. Coordinate the feeder with the installation and manufacturer requirements.
-
Can two 6ES7305-1BA80-0AA0 supplies be paralleled without reviewing the distribution?The product permits a limited parallel arrangement, but wiring, protection and load sharing still require the approved design. Do not use parallel operation as an assumed redundancy scheme or mix unrelated supplies without validation.
-
How should a brief source interruption at 6ES7305-1BA80-0AA0 be evaluated?Compare interruption duration and load with the specified buffering conditions. Observe the output and consumer reset behavior together. The minimum buffering figure applies under its stated conditions and is not an unconditional ride-through guarantee.
-
Why should output adjustments not be assumed on 6ES7305-1BA80-0AA0?The output is not adjustable. Investigate voltage drop, loading and source conditions rather than trying to compensate with an undocumented setting. Changes to the required control voltage call for a suitably specified supply.
Supporting new and legacy automation
-
Please try to be as accurate as possible with your search.
-
We can quote you on 1000s of specialist parts, even if they are not listed on our website.
-
We can't find any results for “”.
Related cases and sourcing guidance
View all case studiesYou May Also Like
Product Browsing History
-
Whatsapp: +86 18030235313
Send us a message. -
sales13@apterpower.com
Complete our online form. -
+86 18030235313
Speak to our team in your native language.