Match the complete marking
Match the complete Siemens 6ES7195-7HB00-0XA0 marking and installed configuration. Confirm the bus-module order number, both positions and rail engagement.
-
Check the offered item before ordering
Request available label and connector photos. Have your maintenance team compare the offered 6ES7195-7HB00-0XA0 with the installed equipment and applicable Siemens documents.
Technical specifications for 6ES7195-7HB00-0XA0
-
Manufacturer:Siemens
-
Product Category:PLC Systems
-
Spare Part Number:6ES7195-7HB00-0XA0
-
Weight:0.12 kg
-
Tariff Code:8537101190
-
Module positions:1 or 2 attached S7-300 modules
-
Compatible I/O width class:40 mm per position
-
Backplane arrangement:Active ET 200M bus
-
Associated cover set:6ES7195-1JA00-0XA0
-
Required rail type:ET 200M rail for module change during operation
Information
- Siemens 6ES7195-7HB00-0XA0 maintains the station backplane arrangement beneath removable I/O modules. Its role is mechanical and bus integration; field-signal characteristics are determined by the attached I/O modules and configured interface.
Slot arrangement: Paired module positions
Service boundary: Rail, covers and interface configuration work together
Unused positions require backplane covers, and the end of the last bus module requires the appropriate bus-module cover. These details preserve the intended assembly when one of the two positions is unused or a module is temporarily removed.
Online replacement depends on the complete interface, module and controller configuration. The process must tolerate the affected I/O state during maintenance. Confirm diagnostics and module recovery through the station rather than assuming an uninterrupted process simply because the backplane remains assembled.
6ES7195-7HB00-0XA0 Original Technical Excerpt
Siemens ET 200M Operating Instructions, EWA-4NEB780600602-08. Selected original pages retain the relevant technical context. PDF · 7 pages.6ES7195-7HB00-0XA0 Installation & Verification Guide
Apter Power installation workbook covering record the station arrangement, check rail and bus engagement, restore i/o position and covers, testing and handover. PDF · 5 pages.
Application scope: The applications describe the complete signal or control path. Confirm the intended function and interface; accessories are supplied only when itemized.
Serviceable distributed I/O
Support compatible I/O in an engineered ET 200M active-backplane station.Paired module positions
Arrange two suitable 40 mm modules on one bus section.Partially occupied stations
Retain a covered spare position for an approved station layout.Existing backplane repair
Restore the original module order and bus-section continuity.
List the interface, active bus sections and attached I/O in physical order. Identify unused positions and the end cover. Establish the approved maintenance state for all affected channels.
Inspect the active-backplane rail and the joining surfaces of adjacent bus sections. Seat the bus module without forcing a misaligned connector and confirm the mechanical position before fitting I/O.
Fit each retained I/O module in its assigned position. Cover unused positions and close the end of the final bus section. Keep the field-wiring assignment with its intended module.
Return the station through the approved sequence and inspect configuration and removal/insertion diagnostics. Check both occupied positions and compare process data with the expected channel behavior.
Remove temporary maintenance substitutions only after the affected channels recover correctly. Retain the final station arrangement and the tested process response.
Retain the final tested settings, physical connection and accepted process response for 6ES7195-7HB00-0XA0.
Alternative Names
Technical notes
Mechanical prerequisite: The active-bus rail and covers are part of the intended installation, not optional substitutes for ordinary module mounting.
System function: Module change during operation requires the correct ET 200M configuration and a controlled process response.
Carrier scope: Do not assign input voltage, output current or channel resolution from an attached I/O module to this bus carrier.
FAQ View All FAQ
-
Can 6ES7195-7HB00-0XA0 be fitted to an ordinary rail for online module replacement?Use the rail intended for the active ET 200M backplane. The ordinary rail arrangement does not establish the same module-change function.
-
What is required when only one position on 6ES7195-7HB00-0XA0 is occupied?Close the unused backplane position with its cover and preserve the correct end-of-station cover arrangement.
-
Does 6ES7195-7HB00-0XA0 guarantee uninterrupted process outputs during removal of an I/O module?No. The affected module and controller configuration determine the I/O response. Plan the process state and diagnostics before replacement.
-
Why should slot order be retained when servicing 6ES7195-7HB00-0XA0?The interface configuration associates physical positions with I/O functions. Moving modules can create configuration mismatch or incorrect application mapping.
-
How is the last active bus section different when using 6ES7195-7HB00-0XA0?It requires the appropriate bus-module end cover in addition to covers for unused module positions.
-
Can an 80 mm module be installed across the two positions of 6ES7195-7HB00-0XA0?The BM 2 x 40 arrangement is for one or two 40 mm modules. Select the dedicated 1 x 80 bus module when the attached module requires that width class.
-
What should be checked after an I/O module is reinserted on 6ES7195-7HB00-0XA0?Confirm mechanical engagement, station diagnostics, restored channel data and the intended process response. Backplane continuity alone is insufficient.
-
Does a redundant interface remove the need to check 6ES7195-7HB00-0XA0 wiring and configuration?No. Redundancy addresses the interface arrangement; the physical I/O positions, covers and controller configuration must still agree.
Supporting new and legacy automation
-
Please try to be as accurate as possible with your search.
-
We can quote you on 1000s of specialist parts, even if they are not listed on our website.
-
We can't find any results for “”.
Related cases and sourcing guidance
View all case studiesYou May Also Like
Product Browsing History
-
6ES7195-7HB00-0XA0Product Details -
6GK7443-1EX11-0XE0Product Details -
6ES7134-4JB51-0AB0Product Details -
6ES7417-4HL04-0AB0Product Details -
6ES7153-2BA82-0XB0Product Details -
6ES7322-1HH01-0AA0Product Details -
6ES7305-1BA80-0AA0Product Details -
6ES7131-4BF00-0AA0Product Details -
6ES7361-3CA01-0AA0Product Details -
6ES7360-3AA01-0AA0Product Details
-
Whatsapp: +86 18030235313
Send us a message. -
sales13@apterpower.com
Complete our online form. -
+86 18030235313
Speak to our team in your native language.