6ES7134-4JB51-0AB0

Resistance Thermometer Analog Input Module
Product image is representative; revision or series may vary. Contact us to request a specific version.

Product Describe:

Siemens 6ES7134-4JB51-0AB0 acquires resistance-thermometer or resistor signals in an ET 200S station. Its channel count depends on the selected two-, three- or four-wire connection method.
  • Manufacturer part number
    6ES7134-4JB51-0AB0
  • Shipping
    Swift global dispatch
  • Condition
    New, original product
  • Shipping size (est.)
    1.4cm x 5.5cm x 8.3cm
  • Country of Origin
    Germany
Get a quick price for 6ES7134-4JB51-0AB0
E-mail *
Mobile
Company
Content *
Quantity *
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)
For more information on how your data is processed and stored by Apterpower please read our privacy policy

What happens after you enquire

  • 0

    Review your reference

    Send the complete 6ES7134-4JB51-0AB0 reference, label photos and required quantity. Confirm the complete module order number, terminal module and sensor wiring topology.

  • 1

    Confirm the offer

    Review the offered execution, condition and included items for 6ES7134-4JB51-0AB0. Confirm the analog electronic module and terminal base only if itemized in the quotation.

  • 2

    Arrange dispatch

    Swift global dispatch. Confirm quantity, dispatch date and delivery details for 6ES7134-4JB51-0AB0 in the quotation.

  • Match the complete marking

    Match the complete Siemens 6ES7134-4JB51-0AB0 marking and installed configuration. Confirm the complete module order number, terminal module and sensor wiring topology.

  • Check the offered item before ordering

    Request available label and connector photos. Have your maintenance team compare the offered 6ES7134-4JB51-0AB0 with the installed equipment and applicable Siemens documents.

Technical specifications for 6ES7134-4JB51-0AB0

  • Manufacturer:
    Siemens
  • Product Category:
    PLC Systems
  • Spare Part Number:
    6ES7134-4JB51-0AB0
  • Weight:
    0.05 kg
  • Tariff Code:
    8537101190
  • Inputs, 3/4-wire:
    2
  • Inputs, 2-wire:
    4
  • RTD types:
    Pt100 and Ni100
  • Resistance ranges:
    150, 300 and 600 ohm; PTC
  • RTD resolution:
    15 bit plus sign
  • Rated load supply:
    24 V DC
  • Sensor excitation:
    1.65 mA; PTC maximum 1.65 mA
  • Shielded cable length:
    200 m maximum
  • Conversion time:
    67 ms at 60 Hz; 80 ms at 50 Hz rejection
  • Load-supply current:
    30 mA maximum
  • Power loss:
    0.6 W typical
  • Input voltage destruction limit:
    9 V maximum

Information

Overview Downloads Applications / Compatibility Product Precautions
  • Siemens 6ES7134-4JB51-0AB0 combines sensor excitation, resistance conversion and characteristic linearization in the distributed I/O channel. Wiring topology, interference suppression and smoothing determine how the measured temperature or resistance reaches the controller.
Sensor processing: Pt100/Ni100 linearization and resistor measurement
Wiring choice: Accuracy and channel capacity depend on connection method
Diagnostic access: Group indication and readable channel information
Separate current and voltage-sense paths give the four-wire connection its measurement advantage. Three-wire operation compensates the relevant lead resistance, while two-wire operation uses fewer terminals but leaves lead resistance in the measurement path. Select the topology to suit the required accuracy.

The conversion timing is linked to mains-frequency rejection and the number of active channels. Digital smoothing further changes response time. A stable display can therefore be slower than the underlying process; assess the complete acquisition and controller update path.

Channel terminals change their role between the two-channel and four-channel arrangements. Preserve the terminal-module and parameter configuration together, then test the physical sensor and its interpreted value. Electrical isolation from load power does not provide isolation between the individual measurement channels.
Controller platform reference: ET 200S resistance measurement. Follow the applicable installation instructions and approved design.
Technical and service documents for Siemens 6ES7134-4JB51-0AB0, separating original engineering information from the installation and verification workflow.
Original manufacturer pages retain their technical context. Use the Apter Power guide with the applicable manufacturer instructions and approved installation design.
System and supply context: Siemens 6ES7134-4JB51-0AB0 integrates with ET 200S resistance measurement. Select companion hardware and configured functions for the actual installed arrangement.

Application scope: The applications describe the complete signal or control path. Confirm the intended function and interface; accessories are supplied only when itemized.
Prepare Siemens 6ES7134-4JB51-0AB0 for its configured installation using these checks.
Preserve the sensor configuration

Record sensor type, range, wire count, active channels, rejection frequency and smoothing. Identify current-excitation and measurement conductors at the terminal base before disconnecting any sensor.

Connect the correct topology

Restore two-, three- or four-wire connections using the terminal roles for the selected mode. Keep the load supply off sensor terminals and inspect shields and contact resistance.

Verify conversion timing

Review active-channel count, mains rejection and wire-break diagnosis. Confirm the smoothing factor and evaluate whether the combined delay suits the monitored process.

Compare controlled resistance values

Use an appropriate sensor simulator or known resistance under the approved procedure. Compare raw and engineering values across relevant operating points and inspect readable diagnostics.

Release temperature supervision

Reconnect the actual sensor, check a plausible stable value and test required fault or process responses. Retain final settings and accepted measurements before removing maintenance substitutions.

Configuration handover

Retain the final tested settings, physical connection and accepted process response for 6ES7134-4JB51-0AB0.

Alternative Names

Siemens 6ES7134-4JB51-0AB0

Technical notes

Terminal reuse: Changing between two-channel and four-channel modes changes the role of some terminals. Validate the actual terminal assignment.

Response budgeting: Conversion, wire-break diagnosis, active-channel count and smoothing all contribute to effective response time.

Sensor boundary: Keep load power away from measurement inputs and account for the absence of isolation between measurement channels.

FAQ View All FAQ

  • How does selecting two-wire operation on 6ES7134-4JB51-0AB0 change measurement accuracy?
    Lead resistance remains in the measured path. The additional channel capacity must be weighed against that error, especially with long sensor runs.
  • Why can stronger smoothing on 6ES7134-4JB51-0AB0 delay an alarm response?
    Smoothing increases the effective time constant in multiples of the module cycle time. Evaluate the sensor, conversion, filter and controller delays together.
  • What changes when wire-break diagnostics are enabled for a four-wire channel on 6ES7134-4JB51-0AB0?
    The conversion timing includes an additional diagnostic interval. Include it when estimating the response of all active channels.
  • Can terminals retain the same function after changing the channel mode of 6ES7134-4JB51-0AB0?
    Some terminals are reused as current-excitation lines or additional measurement channels. Review wiring and parameter assignment together before changing mode.
  • Why does the 24 V load supply not belong on a sensor input of 6ES7134-4JB51-0AB0?
    The measurement input has a much lower permitted voltage. Keep power distribution and resistance-sensor terminals separate.
  • Does isolation from L+ mean that channels on 6ES7134-4JB51-0AB0 are isolated from one another?
    No. There is no channel-to-channel isolation. Review common-mode and grounding conditions for the connected sensors.
  • How should a slowly drifting RTD value from 6ES7134-4JB51-0AB0 be investigated?
    Compare sensor and lead condition, terminal contact, wiring topology and actual process temperature before changing calibration or smoothing.
  • What is required after changing mains-frequency rejection on 6ES7134-4JB51-0AB0?
    Reassess conversion and cycle time, then verify the response to a controlled input change and the configured process limits.