6ES7405-0KA02-0AA0

DC-Input Rack Power Supply Module
Siemens 6ES7405-0KA02-0AA0 (1)
Siemens 6ES7405-0KA02-0AA0 (2)
Siemens 6ES7405-0KA02-0AA0 (3)
Siemens 6ES7405-0KA02-0AA0 (1)
Siemens 6ES7405-0KA02-0AA0 (2)
Siemens 6ES7405-0KA02-0AA0 (3)
Product image is representative; revision or series may vary. Contact us to request a specific version.

Product Describe:

Siemens 6ES7405-0KA02-0AA0 powers the S7-400 rack from a DC feeder. Its separate backplane supply rails support the controller and module load, with optional battery backup and dedicated fault indicators.
  • Manufacturer part number
    6ES7405-0KA02-0AA0
  • Shipping
    Swift global dispatch
  • Condition
    New, original product
  • Shipping size (est.)
    22.9cm x 5.1cm x 27.9cm
  • Country of Origin
    Germany
Get a quick price for 6ES7405-0KA02-0AA0
E-mail *
Mobile
Company
Content *
Quantity *
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)
For more information on how your data is processed and stored by Apterpower please read our privacy policy

What happens after you enquire

  • 0

    Review your reference

    Send the complete 6ES7405-0KA02-0AA0 reference, label photographs and installed rack and battery arrangement.

  • 1

    Confirm the offer

    Review the offered release, connector condition, standard supply role and included batteries or accessories.

  • 2

    Arrange dispatch

    Confirm quantity, delivery details and the agreed dispatch date before shipment arrangement.

  • Match the complete marking

    Include the complete 6ES7405-0KA02-0AA0 reference, hardware release and installed rack/backup arrangement.

  • Check the offered item before ordering

    Request nameplate and connector photographs. Have your maintenance team compare the offered 6ES7405-0KA02-0AA0 with the installed rack power supply and applicable Siemens S7-400 instructions.

Technical specifications for 6ES7405-0KA02-0AA0

  • Manufacturer:
    Siemens
  • Product Category:
    PLC Systems
  • Spare Part Number:
    6ES7405-0KA02-0AA0
  • Weight:
    1.4 kg
  • Tariff Code:
    8537101190
  • Rated DC input:
    24 / 48 / 60 V DC
  • Static input range:
    19.2–72 V DC
  • Dynamic input range:
    18.5–75.5 V DC
  • Rated input current:
    4.0 / 2.0 / 1.6 A at 24 / 48 / 60 V
  • Inrush peak:
    18 A
  • Inrush half-value width:
    20 ms
  • Logic-rail rated voltage:
    5.1 V DC
  • Logic-rail capacity:
    10 A
  • Auxiliary-rail rated voltage:
    24 V DC
  • Auxiliary-rail capacity:
    1 A
  • Input power:
    95 W
  • Power loss:
    20 W
  • Mains interruption buffering:
    More than 20 ms, repetition interval 1 s
  • Power-off backup current:
    100 µA maximum
  • Optional backup batteries:
    2 × lithium AA, 3.6 V; use approved battery specification
  • Battery-monitor selection:
    OFF / 1 BATT / 2 BATT
  • Protective separation:
    Yes, according to IEC 61131-2
  • Protection class:
    Class I with protective conductor
  • Overvoltage category:
    II
  • Pollution degree:
    2
  • Secondary-to-PE test:
    700 V DC
  • Primary-to-secondary/PE test:
    2200 V DC
  • Feeder connection:
    3-pin; 3 × 1.5 mm² stranded with ferrules
  • Standby function:
    Outputs to 0 V; no feeder disconnection

Information

Overview Downloads Applications / Compatibility Product Precautions
  • Siemens 6ES7405-0KA02-0AA0 combines rack power conversion with supervision of the backup supply. The front controls allow output standby and fault acknowledgement while keeping the feeder-isolation and data-retention functions distinct.
Independent rail budgeting: The logic and auxiliary rails have different current capacities.
Backup-state visibility: Battery and backplane-backup indicators help separate battery faults from converter faults.
Controlled acknowledgement: FMR clears retained fault indications after the underlying condition has been corrected.
The standard PS 405 10A converts the permitted DC input to the two S7-400 secondary rails. Module loads must be assigned to the correct rail; unused capacity on one rail cannot automatically cover an overload on the other. Its standard designation must not be confused with the separate PS 405 10A R redundant variant.

The standby switch drives the output voltages to zero through the control loop and does not disconnect the incoming power. The three-pin feeder connector must not be inserted or removed under power. The front cover protects the battery connections and controls during operation, while the rack connector and supply position remain part of the installation check.

Two optional batteries support the backup arrangement rather than sustaining normal rack power. The BATT.INDIC selection determines which battery conditions are monitored; BAF concerns the backup voltage on the backplane, while BATT1F and BATT2F identify individual battery problems. A reset is meaningful only after the actual fault and expected monitoring mode have been reconciled.
Controller platform reference: Siemens SIMATIC S7-400 rack power. Check separate rail budgets, backup strategy and rack configuration.
The downloads for Siemens 6ES7405-0KA02-0AA0 separate original rack-power data from an independent service and acceptance workbook. View PDF adds a dedicated dossier covering rail loading, backup behavior and fault interpretation.
Original manufacturer pages retain their technical context. Use the Apter Power guide with the applicable manufacturer instructions and approved installation design.
System and supply context: The module supplies the S7-400 rack through its backplane and requires a suitable DC feeder and protected-earth arrangement. The CPU, I/O modules and any externally supplied equipment remain separate loads with their own requirements.

Application scope: Use the standard PS 405 10A within an approved rack arrangement. Plan normal rail loading, brief interruption handling and battery-backed data retention as separate design questions; the standard module is not a substitute for the redundant R version.
Prepare Siemens 6ES7405-0KA02-0AA0 for its configured installation using these checks.
Isolate beyond the standby switch

Disconnect and secure the feeder before connector or wiring work; output standby is not isolation.

Budget each rail separately

Verify the logic and auxiliary loads independently rather than using one combined current figure.

Preserve the backup strategy

Record battery arrangement and monitoring switch position before a service action.

Correct the fault before FMR

Investigate the indicated condition and then acknowledge retained indications.

Retain the cover and ESD protection

Keep the cover closed in service and discharge static before accessing protected connections.

Respect standard versus redundant variants

Compare the complete 0KA02 reference with the required rack role.

Alternative Names

Siemens 6ES7405-0KA02-0AA0 6ES7405 0KA02 0AA0

Technical notes

Standby boundary: A zero output selected by standby does not prove the feeder connector is de-energized. Use the installation’s isolation procedure before handling it.

Backup indication: A delayed battery alarm after disconnection can reflect internal capacitance. Do not judge the monitoring function from an immediate observation alone.

Restart assessment: If the corrected overload does not permit restart after a few seconds, the applicable recovery guidance calls for removing input power for five minutes before retesting this module.

FAQ View All FAQ

  • Does moving 6ES7405-0KA02-0AA0 to standby make its feeder connector safe to unplug?
    No. Standby acts on the output control loop without disconnecting incoming power. Isolate and secure the external feeder and verify the electrical state before handling the three-pin connector.
  • Why can 6ES7405-0KA02-0AA0 report BAF even when both batteries look correctly installed?
    BAF monitors the backup voltage on the backplane, so other causes include an external backup-path problem, overload or short circuit. Compare individual battery indications with the complete backup circuit rather than replacing batteries solely from BAF.
  • What is the effect of selecting 1 BATT instead of 2 BATT on 6ES7405-0KA02-0AA0?
    The first setting monitors battery 1, while the second enables monitoring of both batteries. Match the selection to the actual backup arrangement and verify the intended alarms; the switch does not create a missing backup battery.
  • Can spare current capacity on the logic rail of 6ES7405-0KA02-0AA0 cover excess 24 V demand?
    No. The rails have separate ratings and load paths. Recalculate the installed modules’ demand for each rail and correct the overloaded allocation rather than relying on a combined wattage or total-current estimate.
  • What distinguishes a retained fault indication from an active overload on 6ES7405-0KA02-0AA0?
    After an overload is removed, the rail indication may flash until FMR is pressed. Check actual load and rail state before acknowledgement; a continuing overload requires corrective action, not repeated resetting.
  • How should 6ES7405-0KA02-0AA0 be assessed if it still fails to restart after a corrected short circuit?
    For this module, the recovery guidance calls for removing input power for five minutes when restart does not occur after a few seconds. Retest only after the fault and load are checked; continued failure requires further hardware assessment.
  • Can the backup batteries in 6ES7405-0KA02-0AA0 keep the entire rack running through a long feeder outage?
    No. Battery-backed retention and normal rack power are different functions. Evaluate process continuity separately from the backup arrangement and the brief input-interruption buffering capability.
  • Would exchanging 6ES7405-0KA02-0AA0 for a PS 405 10A R preserve the same system configuration automatically?
    No. Standard and redundant variants have different intended roles. Verify the complete article number, rack arrangement and redundancy design before accepting a substitution.
Manufacturers

Product Browsing History

Revisit the products you recently viewed on Apter Power.
SPEAK TO OUR TEAM
Let’s find the right solution for you.
Send us the part number, quantity and delivery destination. Our team will help confirm availability and lead time.
  • Whatsapp: +86 18030235313

    Send us a message.
  • sales13@apterpower.com

    Complete our online form.
  • +86 18030235313

    Speak to our team in your native language.