Match the complete marking
Include AAI841-H00 S1 and every revision or approval marking visible on the item. Keep the exact reference on your enquiry and quotation. -
Check the offered item before ordering
Request available label and interface photos. Have your maintenance team compare the offered AAI841-H00 S1 reference with the installed equipment and applicable Yokogawa documentation.
Technical specifications for AAI841-H00 S1
-
Manufacturer:Yokogawa
-
Product Category:DCS Systems
-
Spare Part Number:AAI841-H00 S1
-
Weight:0.3 kg
-
Tariff Code:8537101190
-
Analog inputs:8 channels
-
Input signal:4–20 mA DC
-
Input current limit:25 mA
-
Input accuracy:±16 µA
-
Data update:10 ms
-
Powered input resistance:400 Ω at 20 mA; 1000 Ω at 4 mA
-
Unpowered input resistance:≥500 kΩ
-
Transmitter voltage at 20 mA:≥14.8 V
-
Transmitter voltage at zero current:≤26.4 V
-
5 V supply consumption:310 mA maximum
-
24 V supply consumption:500 mA maximum
-
Temperature drift:±0.1% / 10°C
-
Channel isolation:Non-isolated
-
Input step response:100 ms
-
Analog outputs:8 channels
-
Output signal:4–20 mA DC
-
Output accuracy:±48 µA
-
Output load:0–750 Ω; 200–750 Ω at 60–70°C in a qualified remote node
-
Open-output threshold:<0.65 mA
-
Output step response:40 ms
Information
- The eight-input/eight-output arrangement consolidates loop interfaces while retaining a non-isolated electrical structure.
Response distinction: Input settling and output response are separate timing characteristics.
Exact identity: Retain S1 alongside the HART/basic-type suffix when checking hardware style and node requirements.
Input and output processing do not have identical step-response behavior. A loop test must let the measurement settle while also checking the outgoing command at its receiving load; matching the data-update period to a test interval is not sufficient for either acceptance decision. The input step response is 100 ms and the output response is 40 ms, although the data update is 10 ms. A loop test should therefore record direction and settling condition instead of expecting the same timing at both sides.
The input bank supports the documented transmitter power-mode selection, while the output bank must satisfy receiver-load conditions. The two functions share a module identity but retain distinct fault paths, including output open-circuit detection and remote-node HART support. The input terminal offers at least 14.8 V at 20 mA before external losses; the output bank permits 0–750 Ω under its normal qualified conditions. /A4S00, /A4D00 and /K4A00 identify different ATA4S, ATA4D and ATK4A termination routes.
-
Yokogawa AAI841-H00 S1 official technical excerpt
Original legacy electrical data and H00/H03 suffix selection for the applicable FIO module. PDF, 2 pages. -
Yokogawa AAI841-H00 S1 engineering guide
Apter Power engineering guide for CENTUM FIO analog I/O. Keep measurement and command assignments aligned while evaluating field references and receiver compliance separately. PDF, 3 pages.
Integration boundary: Keep measurement and command assignments aligned while evaluating field references and receiver compliance separately. A paired transmitter/receiver circuit uses the eight-by-eight mapping and its recorded common references. The 310 mA at 5 V and 500 mA at 24 V maximum module demands belong in the node budget, independently of the receiving load.
-
Eight-loop FIO control groups
Map each process measurement and its command output to the intended application, rather than assuming physical adjacency establishes a loop pair. -
Non-isolated transmitter collections
Use field-reference arrangements suitable for the common module architecture. -
Current-command receivers
The output bank drives documented receiver loads; verify current at the receiving end during acceptance. -
Dual-redundant combined modules
Implement the supported node and terminal arrangement before treating the combined I/O as a redundant control interface.
Compare the delivered marking with this specific S1 record rather than accepting a generic H00 label.
Check the non-isolated circuit arrangement before joining grounded field devices.
Allow the input measurement to settle independently; its response differs from the output circuit.
Restore each input’s two-wire or four-wire setting before reconnecting a powered field transmitter.
Check receiver and cable resistance, including any applicable hot remote-node condition.
Test both paths using the approved redundancy procedure; one live indication does not prove both.
Alternative Names
Technical notes
Timing relationship: The faster output step response does not reduce the input path's settling requirement in a closed-loop test.
Fault separation: An open-output indication concerns the receiver current path, while a bad input may arise in its transmitter or power-mode arrangement.
Style control: Retain the full S1 marking in the node maintenance record without assuming equivalence to a later order generation.
FAQ View All FAQ
-
How should input and output accuracy be assessed during an AAI841-H00 S1 loop test?Evaluate input conversion and delivered output current as separate error sources, using each applicable tolerance and receiver/reference condition. A combined end-to-end deviation does not identify which path is responsible.
-
Can AAI835 serve as a channel-for-channel replacement for AAI841-H00 S1?No. It has four inputs and four outputs with channel isolation, rather than this module’s eight-plus-eight non-isolated arrangement. Rework the channel and terminal plan before considering a change.
-
Why can the output settle before the input during an AAI841-H00 S1 test?The two paths have different documented step responses. Test them independently and allow the measurement to settle before judging closed-loop error or adjusting tuning.
-
Can an energized input of AAI841-H00 S1 be assumed to be a suitable loopback load for its output?Not without checking the test circuit. At 4 mA the powered input burden is specified as 1000 Ω, above the normal 750 Ω output-load ceiling. The input power-mode arrangement also matters. Use a compliant test load and measure input and output separately instead of assuming a direct terminal-to-terminal loopback is valid.
-
Does one plausible loop prove all channel pairings on AAI841-H00 S1?No. Project assignment establishes the measurement/command relationship. Exercise each intended pair and check that adjacent loop indications and commands remain correctly mapped.
-
What should be checked before connecting grounded devices to AAI841-H00 S1?Review the non-isolated reference arrangement and terminal wiring against the loop drawings. Similar current ranges do not establish acceptable potential relationships between field circuits.
-
Can AAI841-H00 S1 use the AAI141 overcurrent figure for its input bank?Use the applicable AAI841 electrical table instead. These related modules have different allowable input-current values, so a shared nominal range does not justify borrowing that limit.
-
Can an AAB841 1–5 V input circuit be moved directly onto AAI841-H00 S1?The AAB841 input is a high-impedance voltage interface, while this AAI841 execution measures current through a powered input circuit with an additional protection drop. Preserve the actual field signal type and source capability; use the appropriate voltage-input hardware or an engineered conversion interface rather than treating a similar connector as electrical equivalence.
Supporting new and legacy automation
-
Please try to be as accurate as possible with your search.
-
We can quote you on 1000s of specialist parts, even if they are not listed on our website.
-
We can't find any results for “”.
Related cases and sourcing guidance
View all case studiesYou May Also Like
Product Browsing History
-
Whatsapp: +86 18030235313
Send us a message. -
sales13@apterpower.com
Complete our online form. -
+86 18030235313
Speak to our team in your native language.