Match the complete marking
Include SDV144-S33 and every revision or approval marking visible on the item. Keep the exact reference on your enquiry and quotation.
-
Check the offered item before ordering
Request available label and interface photos. Have your maintenance team compare the offered SDV144-S33 reference with the installed equipment and applicable Yokogawa documentation.
Technical specifications for SDV144-S33
-
Manufacturer:Yokogawa
-
Product Category:DCS Systems
-
Spare Part Number:SDV144-S33
-
Weight:0.28 kg
-
Tariff Code:8537101190
-
Module function:Safety digital input
-
Input type:No-voltage contact
-
Input count:16 channels
-
Channel isolation:Isolated
-
Cable interface:Yokogawa-specific cable
-
Safety classification:Safety application; SIL3 system context
-
Single-module power coefficient A:2
-
Single-module power coefficient B:2
-
Dual-redundant coefficient A:4
-
Dual-redundant coefficient B:4
-
Terminal-board relationship:SED4D / approved digital terminal-board arrangement
-
Wiring-check options:SCB100 open-circuit and SCB110 short-circuit adapters in approved designs
-
Acceptance boundary:Prove field contact, cable, terminal board, module and safety logic as one function
Information
- The complete SDV144-S33 identity establishes the offered hardware. Confirm the installed system, revision and field interfaces before approving the replacement.
Cable boundary: S33 uses the Yokogawa-specific AKB331 cable route.
Proof-test focus: Every safety input requires traceable field-to-logic functional proof.
Safety integrity belongs to the complete sensor, wiring, terminal board, module, logic and final-element function. Module replacement must preserve channel identity, diagnostic adapters and the approved single or redundant configuration.
Commissioning requires a documented proof test for every used channel, including normal, trip and fault-diagnostic states where designed. Any bypass must be controlled and removed before return to service.
-
Yokogawa SDV144-S33 technical reference
Apter Power reference with verified manufacturer data and exact-model applicability. -
Yokogawa SDV144-S33 engineering guide
Apter Power installation, configuration, diagnostic and acceptance guidance.
Platform applications: The uses below depend on the installed controller configuration and approved system design.
-
Emergency shutdown inputs
Acquire isolated dry contacts used by a documented safety-instrumented function. -
Fire and gas trip inputs
Bring approved detector or relay contacts into ProSafe-RS safety logic. -
Redundant safety I/O
Use the module in a manufacturer-supported redundant node arrangement. -
Proof-test maintenance
Verify each sensor-to-logic path and associated cable diagnostics.
Issue, record and remove every temporary safety bypass under the site procedure.
Match cable style, connector keying and terminal-board destination.
Record all sixteen tags, terminals and safety-logic addresses before removal.
Confirm any SCB100 or SCB110 devices and their intended failure coverage.
Operate each source contact and verify raw state, safety logic and alarm/event record.
Document restored bypasses, final healthy state and responsible approval.
Alternative Names
Technical notes
Installation relationship: Use the exact model marking and manufacturer wiring or installation information for the delivered hardware.
System boundary: Verify host equipment, companion interfaces, field wiring and configuration before energizing.
Technical reference: Yokogawa TI 33Q01B10-01E and GS 32Q06K20-31E.
FAQ View All FAQ
-
How should all safety channels of SDV144-S33 be proof-tested?Use the approved cause-and-effect procedure to operate each field contact, verify terminal and raw input state, prove the safety-logic response and restore the normal condition.
-
What cable checks are required for SDV144-S33?Confirm the AKB331 style, connector keying, continuity, insulation method and SED4D or approved terminal-board destination.
-
How should SCB100 and SCB110 adapters be handled with SDV144-S33?Record whether each channel uses open- or short-circuit detection and prove the expected diagnostic without bypassing the safety function.
-
What must be verified before a dual-redundant SDV144-S33 change?Confirm node capacity, paired module state, channel database, switchover procedure and the permitted maintenance bypass.
-
How can a persistent trip input on SDV144-S33 be isolated?Check the field contact, diagnostic adapter, cable pair, terminal board and raw module state before examining application logic.
-
What evidence is needed for SIL-related work on SDV144-S33?Retain the approved proof-test procedure, calibrated test equipment, per-channel results, bypass log, fault findings and final authorization.
-
How should unused channels on SDV144-S33 be treated?Leave them in the approved spare configuration, maintain connector and terminal protection and ensure no unintended safety-logic mapping is active.
-
What closes a replacement of SDV144-S33?All commissioned channels, diagnostics and redundancy functions must pass the approved test, with bypasses removed and the system returned to a healthy recorded state.
Supporting new and legacy automation
-
Please try to be as accurate as possible with your search.
-
We can quote you on 1000s of specialist parts, even if they are not listed on our website.
-
We can't find any results for “”.
Related cases and sourcing guidance
View all case studiesYou May Also Like
Product Browsing History
-
Whatsapp: +86 18030235313
Send us a message. -
sales13@apterpower.com
Complete our online form. -
+86 18030235313
Speak to our team in your native language.