Speak to a sourcing specialist
sales13@apterpower.com

SDV144-S33

16-channel isolated safety digital input module
In Stock
Product image is representative; revision or series may vary. Contact us to request a specific version.

Product Describe:

Yokogawa SDV144-S33 is a 16-channel isolated safety digital input module. Its exact marking, installed interfaces and companion equipment must be verified before replacement or commissioning.
  • Manufacturer part number
    SDV144-S33
  • Shipping
    Swift global dispatch
  • Condition
    New, original product
  • Shipping size (est.)
    3.2cm x 10.6cm x 13cm
  • Country of Origin
    Japan
Get a quick price for SDV144-S33
E-mail *
Mobile
Company
Content *
Quantity *
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)
For more information on how your data is processed and stored by Apterpower please read our privacy policy

What happens after you enquire

  • 0

    Review your reference

    Send the full marking, quantity and label photos. We review the item and any version details that need clarification.

  • 1

    Confirm the offer

    Check the quoted reference, condition, included items and expected dispatch date before approving your order.

  • 2

    Arrange dispatch

    Confirm delivery details and receive the tracking number when it becomes available.

  • Match the complete marking

    Include SDV144-S33 and every revision or approval marking visible on the item. Keep the exact reference on your enquiry and quotation.

  • Check the offered item before ordering

    Request available label and interface photos. Have your maintenance team compare the offered SDV144-S33 reference with the installed equipment and applicable Yokogawa documentation.

Technical specifications for SDV144-S33

  • Manufacturer:
    Yokogawa
  • Product Category:
    DCS Systems
  • Spare Part Number:
    SDV144-S33
  • Weight:
    0.28 kg
  • Tariff Code:
    8537101190
  • Module function:
    Safety digital input
  • Input type:
    No-voltage contact
  • Input count:
    16 channels
  • Channel isolation:
    Isolated
  • Cable interface:
    Yokogawa-specific cable
  • Safety classification:
    Safety application; SIL3 system context
  • Single-module power coefficient A:
    2
  • Single-module power coefficient B:
    2
  • Dual-redundant coefficient A:
    4
  • Dual-redundant coefficient B:
    4
  • Terminal-board relationship:
    SED4D / approved digital terminal-board arrangement
  • Wiring-check options:
    SCB100 open-circuit and SCB110 short-circuit adapters in approved designs
  • Acceptance boundary:
    Prove field contact, cable, terminal board, module and safety logic as one function

Information

Overview Downloads Applications / Compatibility Product Precautions
  • The complete SDV144-S33 identity establishes the offered hardware. Confirm the installed system, revision and field interfaces before approving the replacement.
Safety role: Acquires sixteen isolated dry-contact inputs for a ProSafe-RS safety function.
Cable boundary: S33 uses the Yokogawa-specific AKB331 cable route.
Proof-test focus: Every safety input requires traceable field-to-logic functional proof.
SDV144-S33 is a 16-channel isolated no-voltage-contact input module for the Yokogawa ProSafe-RS safety architecture. Its S33 interface uses the specified AKB331 cable path to the approved terminal-board arrangement.

Safety integrity belongs to the complete sensor, wiring, terminal board, module, logic and final-element function. Module replacement must preserve channel identity, diagnostic adapters and the approved single or redundant configuration.

Commissioning requires a documented proof test for every used channel, including normal, trip and fault-diagnostic states where designed. Any bypass must be controlled and removed before return to service.
Controller platform reference: Safety DCS input. Verify the installed node.
Technical downloads for Yokogawa SDV144-S33: model-specific technical reference and installation review.
Use the manufacturer source identified in each document to confirm applicability to the installed configuration.
System and supply context: The offered item is Yokogawa SDV144-S33, condition New, original product. Companion cables, terminal units, adapters and accessories are separate unless itemized in the quotation.

Platform applications: The uses below depend on the installed controller configuration and approved system design.
Prepare Yokogawa SDV144-S33 using the approved machine documentation and site procedure.
Control bypasses

Issue, record and remove every temporary safety bypass under the site procedure.

Verify AKB331 cable

Match cable style, connector keying and terminal-board destination.

Preserve channel identity

Record all sixteen tags, terminals and safety-logic addresses before removal.

Check diagnostic adapters

Confirm any SCB100 or SCB110 devices and their intended failure coverage.

Prove every channel

Operate each source contact and verify raw state, safety logic and alarm/event record.

Close the proof test

Document restored bypasses, final healthy state and responsible approval.

Alternative Names

Yokogawa SDV144-S33 SDV144 S33

Technical notes

Installation relationship: Use the exact model marking and manufacturer wiring or installation information for the delivered hardware.

System boundary: Verify host equipment, companion interfaces, field wiring and configuration before energizing.

Technical reference: Yokogawa TI 33Q01B10-01E and GS 32Q06K20-31E.

FAQ View All FAQ

  • How should all safety channels of SDV144-S33 be proof-tested?
    Use the approved cause-and-effect procedure to operate each field contact, verify terminal and raw input state, prove the safety-logic response and restore the normal condition.
  • What cable checks are required for SDV144-S33?
    Confirm the AKB331 style, connector keying, continuity, insulation method and SED4D or approved terminal-board destination.
  • How should SCB100 and SCB110 adapters be handled with SDV144-S33?
    Record whether each channel uses open- or short-circuit detection and prove the expected diagnostic without bypassing the safety function.
  • What must be verified before a dual-redundant SDV144-S33 change?
    Confirm node capacity, paired module state, channel database, switchover procedure and the permitted maintenance bypass.
  • How can a persistent trip input on SDV144-S33 be isolated?
    Check the field contact, diagnostic adapter, cable pair, terminal board and raw module state before examining application logic.
  • What evidence is needed for SIL-related work on SDV144-S33?
    Retain the approved proof-test procedure, calibrated test equipment, per-channel results, bypass log, fault findings and final authorization.
  • How should unused channels on SDV144-S33 be treated?
    Leave them in the approved spare configuration, maintain connector and terminal protection and ensure no unintended safety-logic mapping is active.
  • What closes a replacement of SDV144-S33?
    All commissioned channels, diagnostics and redundancy functions must pass the approved test, with bypasses removed and the system returned to a healthy recorded state.
SPEAK TO OUR TEAM
Let’s find the right solution for you.
Send us the part number, quantity and delivery destination. Our team will help confirm availability and lead time.
  • Whatsapp: +86 18030235313

    Send us a message.
  • sales13@apterpower.com

    Complete our online form.
  • +86 18030235313

    Speak to our team in your native language.