ADV869-P00 S1

CENTUM VP 32-channel digital input and 32-channel digital output module for ST5
In Stock
Ships by Sunday, September 20
Fast Shipping Available

Product Describe:

Yokogawa ADV869-P00 S1 is a CENTUM VP 32-channel digital input and 32-channel digital output module for ST5. It combines thirty-two isolated digital inputs with thirty-two transistor outputs and supports pulse-width output through a compatible ST5 terminal board.

Ask our team:

Get a quick price for: ADV869-P00 S1
Quantity*
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)
For more information on how your data is processed and stored by Apterpower please read our privacy policy.

Technical specifications for ADV869-P00 S1

Technical specifications for ADV869-P00 S1

  • Manufacturer:
    Yokogawa
  • Product Category:
    DCS System
  • Spare Part Number:
    ADV869-P00 S1
  • Estimated shipping dimensions:
    3.2x10.6x13cm
  • Weight:
    0.2 kg
  • Tariff Code:
    8537101190
  • Counliy of origin:
    Japan
  • Digital inputs:
    32
  • Digital outputs:
    32
  • Compatible terminal board:
    ST5
  • Isolation:
    Isolated; common minus every 16 channels
  • Contact input OFF:
    100 kohm or more
  • Contact input ON:
    200 ohm or less
  • Minimum short-circuit current:
    1.25 mA
  • Voltage input OFF:
    4.5 to 25 V DC
  • Voltage input ON:
    +/-1 V DC, 200 ohm or less
  • Input contact rating:
    5 V DC, 20 mA or more
  • Input response:
    8 ms
  • Output device:
    Transistor contact
  • Output rating:
    30 V DC, 100 mA
  • Output response:
    16 ms maximum
  • Pulse width:
    8 ms to 7200 s
  • Pulse resolution:
    8 ms plus 1 ms maximum delay
  • Current consumption:
    800 mA maximum at 5 V DC
  • External cable:
    KS9

Information

Information

Overview Manuals Common Applications Product Precautions
Yokogawa ADV869-P00 S1 is centum vp 32-channel digital input and 32-channel digital output module for st5. It combines thirty-two isolated digital inputs with thirty-two transistor outputs and supports pulse-width output through a compatible ST5 terminal board.
  • Combines thirty-two inputs and thirty-two outputs
  • Groups channel commons in sets of sixteen
  • Supports timed pulse-width output
  • Connects to ST5 through the KS9 cable

ADV869-P00 S1 operates with CENTUM VP node unit, ST5 terminal board, KS9 external cable, field contacts and 30 VDC loads.

Engineered applications include Package-machine mixed digital I/O, Valve and interlock station, Time-proportional actuator command, CENTUM VP I/O replacement.

Important Notice: Verify ADV869-P00 S1, ST5 terminal-board identity, KS9 cable, sixteen-channel common groups, input thresholds and output load ratings; record all sixty-four channel assignments and test pulse timing before process release.

Apter Power Yokogawa ADV869-P00 S1 Manuals and Guides

Apter Power Yokogawa ADV869-P00 S1 Product and System Technical Reference PDFApter Power Yokogawa ADV869-P00 S1 Installation and Commissioning Workbook PDF

The first document presents model-specific engineering data. The second provides a separate installation, connection, commissioning and acceptance workflow.

Package-machine mixed digital I/O

Combines equipment status acquisition and discrete commands in one field station.

Valve and interlock station

Coordinates permissive contacts with valve or relay outputs.

Time-proportional actuator command

Provides timed output pulses for approved actuators.

CENTUM VP I/O replacement

Restores the ST5 arrangement while preserving all sixty-four channel assignments.

Read the applicable Yokogawa instructions before work. Verify ADV869-P00 S1 and the installed Yokogawa CENTUM VP I/O configuration.
1

Verify the complete ADV869-P00 S1 marking and its assigned Yokogawa CENTUM VP I/O position before work.

2

Place the connected package-machine mixed digital i/o process in the approved maintenance state.

3

Isolate applicable power and thirty-two digital inputs and thirty-two transistor digital outputs field energy before disconnecting conductors.

4

Record connector, conductor, address, firmware and software identities before removal.

5

Use ESD controls and protect keyed interfaces, exposed contacts and electronic assemblies.

6

Confirm the installed CENTUM VP node unit and ST5 terminal board against the approved project.

7

Restore power in a controlled sequence and review device, network and host diagnostics.

8

Prove the intended valve and interlock station function and retain the final test result.

Technical notes

Technical notes

Verify ADV869-P00 S1, ST5 terminal-board identity, KS9 cable, sixteen-channel common groups, input thresholds and output load ratings; record all sixty-four channel assignments and test pulse timing before process release.

FAQS

  • Which installed system position is intended for ADV869-P00 S1?
    Install ADV869-P00 S1 only in the documented Yokogawa CENTUM VP I/O position and compare the complete catalog marking with the approved hardware list.
  • What field signals or controlled function does ADV869-P00 S1 handle?
    Its documented role is thirty-two digital inputs and thirty-two transistor digital outputs; preserve the assigned channel, network or controller function during service.
  • Which companion hardware must be matched to ADV869-P00 S1?
    Match ADV869-P00 S1 with CENTUM VP node unit and ST5 terminal board, including the documented rack, cable and project identity.
  • Which electrical rating must be checked before wiring ADV869-P00 S1?
    Verify digital outputs: 32. Do not transfer limits from another catalog number.
  • What configuration should be recorded before replacing ADV869-P00 S1?
    Record the as-found position, conductors, addressing, firmware and software revision, then restore only the approved Yokogawa CENTUM VP I/O configuration.
  • Which isolation and handling controls apply to ADV869-P00 S1?
    Isolate all documented supply and field energy, use ESD controls and protect keyed connectors before handling ADV869-P00 S1.
  • How should an engineer commission ADV869-P00 S1?
    Power up in a controlled sequence, review device and host diagnostics, then prove the intended package-machine mixed digital i/o function.
  • Can ADV869-P00 S1 replace a visually similar module without an engineering review?
    No automatic substitution is assumed; compare the complete catalog number, interfaces, ratings and approved system revision.
Trusted by 5,000+ plants worldwide | Backed by our vast inventory of top-tier control parts, modules and cards, fast shipments are dispatched to cover your urgent needs. ABOUT US >>
Disclaimer: We are not an authorized distributor or distributor of the product manufacturer of this website, The product may have older date codes or be an older series than that available direct from the factory or authorized dealers. Because our company is not an authorized distributor of this product, the Original Manufacturer`s warranty does not apply.While many DCS PLC products will have firmware already installed, Our company makes no representation as to whether a DSC PLC product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Our company also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from our company, its distributors, or any other source. Our company also makes no representations as to your right to install any such firmware on the product. Our company will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.

Product Browsing History

We’re Here When You Need Us

From product insights to customer service needs, our experienced service team will focus on getting you what you need quickly

Enquire

Complete our online form.

Call Us

Speak to one of our team.

Live Chat

Send us a message.