With more than 30.000 high-quality spare parts, they can be sold immediately. Our large inventory allows us to quickly meet customer needs, thereby reducing downtime and protecting production schedules. Our timely delivery time provides you with security and save money.
The AMM12 S3 is a high-performance voltage input multiplexer module designed for industrial automation systems. It consolidates multiple analog voltage signals into a single module, simplifying system architecture and reducing the number of required input cards. Its compact design allows for easy integration into Yokogawa DCS and other automation platforms.
High Precision
Multiple Channels
Robust Design
AMM12 S3 provides fast analog signal sampling with high precision and linearity, supporting up to 12 input channels sequentially. Equipped with robust voltage isolation and interference resistance, it ensures reliable data acquisition even in harsh industrial environments. Its multiple communication interfaces allow seamless integration with SCADA and process control systems.
Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description.
Yokogawa AMM12 S3 Voltage Input Multiplexer Manuals, Datasheets, Drivers, Link
Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description.
Oil & Gas
Used for monitoring analog signals from drilling rigs, pumping stations, and pipelines. Ensures accurate process control and reliable data acquisition in upstream and midstream operations.
Chemical Plants
Manages analog inputs from reactors, mixers, and storage tanks. Supports automation of chemical processes with precise voltage signal measurement and monitoring.
Water Treatment
Controls pumps, valves, and filtration systems by acquiring voltage signals from sensors. Enables efficient operation and remote monitoring of treatment processes.
Power Generation
Monitors voltage signals from turbines, generators, and auxiliary equipment. Ensures stable operation and precise control in power plants.
Food & Beverage
Automates production lines such as bottling, mixing, and packaging using analog voltage inputs. Maintains product quality and consistency through precise signal monitoring.
Pharmaceutical Manufacturing
Controls production equipment for tablets, liquids, and sterile packaging. Supports compliance with regulatory standards and ensures process repeatability.
The AMM12 S3 is installed into the Yokogawa DCS rack and connects to up to 12 analog voltage input channels. Each channel is configurable through the DCS engineering workstation, allowing selection of voltage range, sampling rate, and signal type. Proper grounding and shielding are recommended to minimize noise and maintain measurement accuracy.
The Yokogawa AMM12 S3 is a voltage input multiplexer module designed for industrial automation and control systems. It consolidates multiple analog voltage signals into a single module for efficient data acquisition. This helps simplify system architecture and reduce the number of input cards required.
What accuracy and performance does AMM12 S3 offer?
The AMM12 S3 is designed for high‑speed sampling and precise voltage measurement, typically offering excellent linearity and resolution suited for real‑time process control. Fast switching times also support timely acquisition of analog data across all channels.
What environments can AMM12 S3 operate in?
The module is built to operate in standard industrial environments with a typical temperature range from about -20 °C to +60 °C. Its rugged design helps withstand electromagnetic interference and supports reliable operation in automation systems.
Is AMM12 S3 compatible with Yokogawa control systems?
Yes, the AMM12 S3 module is compatible with Yokogawa Distributed Control Systems (DCS), including legacy CENTUM CS and modern CENTUM VP platforms. This ensures seamless integration into existing Yokogawa automation networks.
What is the typical input voltage range of AMM12 S3?
The typical analog voltage input range for the AMM12 S3 is approximately -10 V DC to +10 V DC, accommodating most standard industrial sensors and process signals. This range ensures compatibility with common voltage‑based measurement devices.
Trusted by 5,000+ plants worldwide | Backed by our vast inventory of top-tier control parts, modules and cards, fast shipments are dispatched to cover your urgent needs. ABOUT US >>
Disclaimer: We are not an authorized distributor or distributor of the product manufacturer of this website, The product may have older date codes or be an older series than that available direct from the factory or authorized dealers. Because our company is not an authorized distributor of this product, the Original Manufacturer`s warranty does not apply.While many DCS PLC products will have firmware already installed, Our company makes no representation as to whether a DSC PLC product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Our company also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from our company, its distributors, or any other source. Our company also makes no representations as to your right to install any such firmware on the product. Our company will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.