-
Match the complete marking
Include AAI841-H03 S1 and every revision or approval marking visible on the item. Keep the exact reference on your enquiry and quotation. -
Check the offered item before ordering
Request available label and interface photos. Have your maintenance team compare the offered AAI841-H03 S1 reference with the installed equipment and applicable Yokogawa documentation.
Technical specifications for AAI841-H03 S1
-
Manufacturer:Yokogawa
-
Product Category:DCS Systems
-
Spare Part Number:AAI841-H03 S1
-
Weight:0.3 kg
-
Tariff Code:8537101190
-
Analog inputs:8 channels
-
Input signal:4–20 mA DC
-
Input current limit:25 mA
-
Input accuracy:±16 µA
-
Data update:10 ms
-
Powered input resistance:400 Ω at 20 mA; 1000 Ω at 4 mA
-
Unpowered input resistance:≥500 kΩ
-
Transmitter voltage at 20 mA:≥14.8 V
-
Transmitter voltage at zero current:≤26.4 V
-
5 V supply consumption:310 mA maximum
-
24 V supply consumption:500 mA maximum
-
Temperature drift:±0.1% / 10°C
-
Channel isolation:Non-isolated
-
Input step response:100 ms
-
Analog outputs:8 channels
-
Output signal:4–20 mA DC
-
Output accuracy:±48 µA
-
Output load:0–750 Ω; 200–750 Ω at 60–70°C in a qualified remote node
-
Open-output threshold:<0.65 mA
-
Output step response:40 ms
-
Temperature option:−20 to +70°C; compatible host/node required
-
Atmosphere option:ISA Standard G3
Information
- An eight-loop module can meet an environmental option while still requiring non-isolated field-reference and temperature-dependent output-load checks.
Output condition: A qualified remote node at 60–70°C requires 200–750 Ω output load.
Reference architecture: Eight inputs and eight outputs remain non-isolated, unlike AAI835.
The output load must be assessed at the node's operating condition. A receiver that works in a cool cabinet or short bench circuit may fail the documented hot remote-node load requirement; cable and receiver resistance must be evaluated together. The 200–750 Ω output-load condition applies to the qualified remote arrangement at 60–70°C. Check each receiver branch, including any temporary test resistor, rather than accepting one representative loop for the whole output bank.
Measurement supply, output compliance and digital instrument communication use different acceptance evidence. The input setting pins establish the transmitter arrangement, the loaded output test proves the receiver path, and remote HART requires the supporting EB401 revision in addition to an H-marked card. The specified temperature influence is ±0.1% per 10°C. Assess this temperature influence separately from the different ±16 µA input and ±48 µA output reference accuracies.
-
Yokogawa AAI841-H03 S1 official technical excerpt
Original legacy electrical data and H00/H03 suffix selection for the applicable FIO module. PDF, 2 pages. -
Yokogawa AAI841-H03 S1 engineering guide
Apter Power engineering guide for CENTUM FIO analog I/O. Retain the required environmental suffix while qualifying non-isolated circuit references and remote-node load conditions. PDF, 3 pages.
Integration boundary: Retain the required environmental suffix while qualifying non-isolated circuit references and remote-node load conditions. Use the selected ATA4S/ATA4D or ATK4A termination with the recorded shared commons and all sixteen direction-labeled circuits. H03 ambient qualification, node rail capacity and remote HART revision are independent fit conditions.
-
H03 combined-I/O replacement
Preserve the selected G3/temperature execution when restoring an existing eight-loop installation. -
Hot remote-node command circuits
Engineer the complete output resistance window rather than relying on a maximum-load check alone. -
High-density current-loop groups
Coordinate eight measurements and eight receiver commands with the project's actual loop allocation. -
Digital maintenance alongside control
Verify HART instrument access without treating it as evidence of correct command delivery.
Compare the complete H03 S1 marking before accepting a unit matching only the AAI841 base number.
Record ambient and node type to determine whether the high-temperature load restriction applies.
Check the applicable minimum and maximum load; a short test loop can violate the lower limit.
Preserve field commons and return assignments; the H03 G3 option does not add channel isolation.
Do not use the faster output response to judge input acquisition immediately after a step.
After analog checks, verify EB401 revision and prove remote HART from the maintenance station.
Alternative Names
Technical notes
Thermal compliance: The hot remote-node output requirement introduces a minimum resistance as well as the ordinary maximum.
Reference design: The environmental suffix does not change the non-isolated input/output architecture.
Acceptance order: Verify the transmitter power setting and input settling before combining the measurement with a separately proven command output.
FAQ View All FAQ
-
Why is a maximum-load check alone incomplete for AAI841-H03 S1?At the documented hot remote-node condition the output also has a minimum load. Evaluate the complete receiver-plus-wire resistance against both limits at the relevant ambient.
-
Does the G3 selection of AAI841-H03 S1 establish hazardous-area explosion protection?G3 describes the selected environmental atmosphere capability; it is not an explosion-protection approval. Keep the H03 order-field meanings separate and verify the complete approved field-loop architecture for a classified installation. Passing analog tests or retaining the G3 option cannot establish an otherwise unspecified protection method.
-
Does AAI841-H03 S1 provide channel isolation because it has a G3 option?No. G3 and temperature execution concern environmental selection; this module’s current input/output architecture remains non-isolated. Verify field references accordingly.
-
How much load margin remains if an output of AAI841-H03 S1 has a 680-ohm receiver and 60-ohm wiring?The nominal series load is 740 Ω, leaving only 10 Ω below the 750 Ω upper limit. At a qualified 60–70°C remote node it also lies above the 200 Ω minimum, but resistor tolerance, terminals and wiring-temperature changes can consume the small upper margin. Check worst-case installed resistance rather than accepting the nominal sum alone.
-
Why can changing the input power-mode setting affect only some AAI841-H03 S1 loops?The two-wire/four-wire choice is per input channel. Compare each transmitter’s supply arrangement with its setting rather than assigning one assumption to all eight measurements.
-
What distinguishes input delay from output failure on AAI841-H03 S1?Test incoming current and outgoing receiver current separately. Allow the input path its documented settling interval before concluding that a closed-loop discrepancy originates in the output hardware.
-
Can AAI841-H03 S1 replace an isolated four-loop module without a circuit review?No. It changes both circuit isolation and channel allocation. Review terminal mapping, field references and project assignments before moving from AAI835 to this eight-loop arrangement.
-
Can a one-point input adjustment on AAI841-H03 S1 correct both I/O banks over temperature?A correction to one input point does not prove the output transfer function or remove temperature-dependent error. Retain separate input and output acceptance measurements under the required operating conditions, and include the published temperature-drift condition in the error budget. The H03 ambient option identifies the permitted execution, not automatic cancellation of those errors.
Supporting new and legacy automation
-
Please try to be as accurate as possible with your search.
-
We can quote you on 1000s of specialist parts, even if they are not listed on our website.
-
We can't find any results for “”.
Related cases and sourcing guidance
View all case studiesYou May Also Like
Product Browsing History
-
Whatsapp: +86 18030235313
Send us a message. -
sales13@apterpower.com
Complete our online form. -
+86 18030235313
Speak to our team in your native language.





