IS200VRTDH1DAC

RTD Input Processor Board
Product image is representative; revision or series may vary. Contact us to request a specific version.

Product Describe:

This Mark VI VME board converts 16 three-wire RTD inputs into controller temperature values. Correct service depends on the selected sensor characteristic and scan mode; a resistance input cannot be assigned one temperature range for every RTD type.
  • Manufacturer part number
    IS200VRTDH1DAC
  • Shipping
    Swift global dispatch
  • Condition
    New, original product
  • Shipping size (est.)
    2cm x 18.5cm x 26.1cm
  • Country of Origin
    USA
Get a quick price for IS200VRTDH1DAC
E-mail *
Mobile
Company
Content *
Quantity *
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)
For more information on how your data is processed and stored by Apterpower please read our privacy policy

What happens after you enquire

  • 0

    Review your reference

    Send the full marking, quantity and label photos. We review the item and any version details that need clarification.
  • 1

    Confirm the offer

    Check the quoted reference, condition, included items and expected dispatch date before approving your order.
  • 2

    Arrange dispatch

    Confirm delivery details and receive the tracking number when it becomes available.
  • Match the complete marking

    Include IS200VRTDH1DAC and every hardware or assembly-revision marking visible on the item. Keep the exact reference on your enquiry and quotation.
  • Check the offered item before ordering

    Request available label and interface photos. Have your maintenance team compare the offered IS200VRTDH1DAC reference with the installed equipment and applicable General Electric documentation.

Technical specifications for IS200VRTDH1DAC

  • Manufacturer:
    General Electric
  • Product Category:
    Gas Turbine Control
  • Spare Part Number:
    IS200VRTDH1DAC
  • Weight:
    0.3 kg
  • Tariff Code:
    8537101190
  • RTD input capacity:
    16
  • Sensor connection:
    3 wire
  • RTD excitation:
    10 mA DC, pulsed
  • ADC resolution:
    14 bit
  • Normal scan period:
    250 ms
  • Fast scan provision:
    40 ms / 25 Hz; not TMR
  • Input electrical span:
    0.3532-4.054 V
  • Maximum two-way lead resistance:
    15 ohm
  • Maximum stated lead distance:
    300 m
  • Processor consumption:
    Less than 12 W
  • Front indicators:
    3: RUN, FAIL, STATUS
  • Configurable input groups:
    2 x 8 inputs
  • Normal line-frequency rejection:
    50 Hz or 60 Hz
  • Higher-gain resistance condition:
    Gain 2.0 below 190 ohm

Information

Overview Downloads Applications / Compatibility Product Precautions
  • General Electric IS200VRTDH1DAC turns detector resistance into temperature using selected curves and two independently configured input groups, so group settings are central to fault isolation.
Input grouping: Two groups of eight inputs have separate rate and gain settings.
Conversion choices: Resistance and temperature modes require different acceptance records.
Fault isolation: Invalid channels can be removed from scanning without stopping all RTD processing.
IS200VRTDH1DAC measures the signals arriving from TRTD or DRTD terminations and applies a selected detector linearization. Platinum, copper and nickel curves differ in nominal resistance and valid temperature span; resistance-mode operation is a separate selection. Preserve the actual detector curve when transferring the project, rather than treating the engineering-unit label as sufficient configuration.

The first eight and second eight inputs have independent rate and gain choices. The normal 4 Hz mode includes a 50 Hz or 60 Hz rejection selection; the 25 Hz option has architecture restrictions and is not available for TMR. Gain 2.0 is intended for improved accuracy below 190 ohms, while the 10 ohm copper selection has its own gain option.

Hardware electrical checks and configurable temperature limits have different consequences. A hardware-invalid input leaves the scan, whereas a system limit can generate enabled/latching application signals. A diagnosis should retain the resistance, curve, group settings and reset history, so a repaired wire is not confused with an unreset or not-yet-reinstated channel.
Controller platform reference: GE Mark VI RTD conversion. Match the RTD curve and scan mode.
Use the configured detector curve and input-group settings when testing temperature conversion and fault recovery.
Save group settings

Record rate, line-frequency rejection and gain for each eight-input group before removing the VRTD.

Check configured sensor type

Preserve CU10, the selected PT100 variant, N120 or other approved characteristic exactly; nominal resistance alone does not identify every curve.

Avoid an invalid fast-mode change

Confirm the architecture before enabling 25 Hz operation; use the supported normal filtered mode in TMR.

Retain unused channel state

Keep unconnected inputs configured unused so an absent detector does not become a misleading active measurement.

Clear the appropriate latch

Diagnose hardware removal from scan separately from a latching high/low system limit before issuing a reset.

Prove the working region

Use several resistance points within the selected curve and gain region, recording input resistance and converted temperature together.

Alternative Names

GE IS200VRTDH1DAC General Electric IS200VRTDH1DAC

Technical notes

Recovery timing: An automatically reinstated channel can take up to the documented 20-second recovery interval; compare that behavior with manual-reinstatement configuration after repairing the circuit.

Electrical range: The 0.3532-4.054 V input electrical span is an internal measurement boundary, not a common operating temperature range for all detectors.

Channel identifiers: A connector ID contains the termination type and location. A wrong terminal/cable identity must be corrected before a curve or calibration adjustment is used to explain the fault.

FAQ View All FAQ

  • Why do eight inputs on IS200VRTDH1DAC show a different response time from the other eight?
    Group A and Group B have independent rate/filter settings. Compare the two group configurations and use the same controlled resistance transition before attributing the difference to the sensor wiring.
  • How should a Pt100 test above 190 ohms be planned for IS200VRTDH1DAC?
    The Gain 2.0 accuracy provision is conditioned on resistance below 190 ohms. Review the configured gain and intended working region; do not extend that accuracy implication beyond its stated resistance condition.
  • Can IS200VRTDH1DAC use one generic Pt100 curve for every platinum detector?
    Several Pt100 characteristics are selectable. Match the actual detector standard, then compare resistance/temperature points across the required range; a common 100-ohm nominal value does not establish identical conversion.
  • What does diagnostic 156 mean when IS200VRTDH1DAC is commissioned in TMR?
    The configured 25 Hz rate is incompatible with TMR. Restore the supported 4 Hz setting with the appropriate 50/60 Hz rejection, then verify the configuration and channel diagnostics.
  • Why can IS200VRTDH1DAC continue to report a repaired input as invalid?
    The channel may remain removed from scan or latched according to recovery configuration. Check present resistance, the original hardware diagnostic and reinstatement/reset state before making another hardware change.
  • How can IS200VRTDH1DAC help distinguish a wrong curve from a cable compensation error?
    Compare a known resistance applied at the termination with the selected linearization, then repeat through the field leads using the approved three-wire method. A terminal test that passes while the field-path test fails directs investigation to leads/connections.
  • Why should an unused input on IS200VRTDH1DAC be disabled rather than assigned a fictitious resistance?
    Unused is a supported channel selection that removes an absent detector from scanning. A fabricated valid value hides the true channel allocation and can mislead the temperature application.
  • What should be checked when IS200VRTDH1DAC indicates a cable-ID failure on J3 or J4?
    Trace the named connector and termination identity, then inspect its cable and seating. This is an interface-identification path; changing detector coefficients does not repair a failed ID connection.