This terminal board connects two servo-valve circuits and their LVDT feedback to a Mark VI VSVO processor. Its field-terminal role includes the output shutdown interface, so coil selection, feedback wiring and trip-clamp connections must remain aligned.
  • Manufacturer part number
    IS200TSVOH1BDC
  • Shipping
    Swift global dispatch
  • Condition
    New, original product
  • Shipping size (est.)
    33cm x 17.7cm x 2.5cm
  • Country of Origin
    USA
Get a quick price for IS200TSVOH1BDC
E-mail *
Mobile
Company
Content *
Quantity *
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)
For more information on how your data is processed and stored by Apterpower please read our privacy policy

What happens after you enquire

  • 0

    Review your reference

    Send the full marking, quantity and label photos. We review the item and any version details that need clarification.
  • 1

    Confirm the offer

    Check the quoted reference, condition, included items and expected dispatch date before approving your order.
  • 2

    Arrange dispatch

    Confirm delivery details and receive the tracking number when it becomes available.
  • Match the complete marking

    Include IS200TSVOH1BDC and every hardware or assembly-revision marking visible on the item. Keep the exact reference on your enquiry and quotation.
  • Check the offered item before ordering

    Request available label and interface photos. Have your maintenance team compare the offered IS200TSVOH1BDC reference with the installed equipment and applicable General Electric documentation.

Technical specifications for IS200TSVOH1BDC

  • Manufacturer:
    General Electric
  • Product Category:
    Gas Turbine Control
  • Spare Part Number:
    IS200TSVOH1BDC
  • Weight:
    0.56 kg
  • Tariff Code:
    8537101190
  • Servo outputs:
    2
  • LVDT input windings:
    6
  • LVDT/R excitation sources per terminal:
    2 simplex; 4 TMR
  • Servo current selection span:
    10-120 mA
  • LVDT excitation, matched path:
    7.00 +/-0.14 V rms
  • LVDT excitation frequency:
    3.2 +/-0.2 kHz
  • Servo sampling, matched path:
    200 Hz
  • Servo conversion resolution:
    12 bit
  • LVDT conversion resolution:
    14 bit
  • Servo accuracy, matched path:
    2%
  • LVDT accuracy, matched path:
    1%
  • LVDT/R maximum two-way lead resistance:
    15 ohm
  • LVDT/R maximum stated distance:
    300 m
  • Loaded excitation distortion:
    Less than 1% THD

Information

Overview Downloads Applications / Compatibility Product Precautions
  • General Electric IS200TSVOH1BDC carries the actuator-side coil and displacement-feedback wiring; the selected coil resistance and termination jumpers establish the electrical load seen by VSVO.
Coil matching: Current rating and coil resistance must be considered together.
Feedback topology: Four-wire LVDT and three-wire LVDR use different field connections.
Trip connection: The installed JD1 clamp path is separate from normal valve positioning.
IS200TSVOH1BDC is the two-loop TSVO termination used with Mark VI VSVO processing. The coil-selection table distinguishes simplex and TMR loads: equal nominal current does not imply equal permissible coil resistance. For example, the documented 40 mA choices use 62 ohm simplex and 89 ohm TMR coils; the correct setting follows the actual actuator and architecture.

Valve position can be returned by a four-wire LVDT or a three-wire LVDR. The excitation source floats relative to signal common, while the measured feedback is converted and checked in the processor. Preserve the actual winding connections and approved stroke direction; a typical increase in RMS feedback is not a universal rule for every valve installation.

In the applicable simplex trip arrangement, TREG J1 connects to TSVO JD1 to clamp the servo on turbine trip. This path and the coil shorting function have a different purpose from ordinary position control. A successful stroke test therefore cannot replace the site-approved trip/clamp proof.
Controller platform reference: GE Mark VI servo valve termination. Retain coil and LVDT assignments.
Control actuator authority while checking coil selection, winding direction and the independent trip-clamp interface.
Measure the isolated coil

Compare winding resistance with the selected current and architecture before copying terminal jumper positions.

Keep excitation floating

Do not add a signal-common bond to the LVDT/R excitation without the approved wiring basis.

Retain stroke orientation

Record feedback at the approved end positions before dismantling the connection; some applications reverse the usual RMS progression.

Check long sensor routes

Apply the 300 m route allowance together with the maximum 15 ohm two-way resistance for LVDT/R wiring.

Separate clamp testing

Test the JD1 trip interface under the approved shutdown procedure, independently of normal servo command following.

Validate both terminal loops

Prove each coil/feedback assignment separately so crossed loop wiring is not masked by an apparently moving valve.

Alternative Names

GE IS200TSVOH1BDC General Electric IS200TSVOH1BDC

Technical notes

Coil-selection example: The 120 mA selections distinguish a 40 ohm simplex coil from a 75 ohm TMR coil; the current label alone does not establish the proper jumper configuration.

Excitation quality: The matched LVDT/R source is specified with less than 1% loaded harmonic distortion; evaluate waveform quality as well as RMS amplitude during feedback diagnosis.

Feedback common mode: The floating excitation supports the stated common-mode allowance up to 35 V DC or 35 V RMS at 50/60 Hz; this is not permission to apply that voltage as the sensor excitation.

FAQ View All FAQ

  • Why can IS200TSVOH1BDC need a different setting for two 40 mA coils?
    The standard table associates 62 ohms with simplex and 89 ohms with TMR at that current. Match the measured winding and architecture to the complete table rather than selecting on nominal mA alone.
  • Can the typical feedback endpoints be used as calibration setpoints for IS200TSVOH1BDC?
    The typical LVDT/R RMS endpoints can be reversed in some applications. Establish the valve-specific mechanical endpoints and approved configuration, then verify feedback direction before closing the loop.
  • Why can an LVDT signal on IS200TSVOH1BDC change after adding a common wire?
    Its excitation is intentionally floating. Review the added bond, sensor topology and approved return path; an unintended common can alter the measurement reference even when the RMS amplitude remains plausible.
  • How should IS200TSVOH1BDC be checked when the valve moves correctly but fails the shutdown proof?
    Trace the installed TREG/JD1 clamp connection and output shorting path separately from command tracking. Verify the intended protective action under the machine shutdown procedure without treating ordinary movement as trip evidence.
  • Can the number of excitation sources on IS200TSVOH1BDC be assumed identical in simplex and TMR?
    The documented terminal arrangement uses two sources for simplex and four for TMR. Confirm the architecture and actual sensor assignment before interpreting a spare excitation connection as a missing circuit.
  • What makes an LVDT/R cable acceptable for IS200TSVOH1BDC at the maximum route length?
    It must also satisfy the maximum two-way resistance and retain the intended conductor arrangement. Measure the installed path including connections; distance alone does not prove excitation and feedback integrity.
  • How can crossed feedback windings at IS200TSVOH1BDC be detected before enabling the servo?
    With motion safely controlled, compare each named feedback channel with the corresponding valve position while the other loop remains fixed. Record both channel assignment and direction before restoring closed-loop authority.
  • Does IS200TSVOH1BDC require every non-standard coil to be rejected?
    The manufacturer describes non-standard selection by matching the total resistance, including an 80 mA, 125 ohm example using setting 120B. Such a selection requires the applicable coil-table engineering calculation, not a copied standard jumper pattern.