Match the complete marking
Include IS200TSVOH1BDC and every hardware or assembly-revision marking visible on the item. Keep the exact reference on your enquiry and quotation. -
Check the offered item before ordering
Request available label and interface photos. Have your maintenance team compare the offered IS200TSVOH1BDC reference with the installed equipment and applicable General Electric documentation.
Technical specifications for IS200TSVOH1BDC
-
Manufacturer:General Electric
-
Product Category:Gas Turbine Control
-
Spare Part Number:IS200TSVOH1BDC
-
Weight:0.56 kg
-
Tariff Code:8537101190
-
Servo outputs:2
-
LVDT input windings:6
-
LVDT/R excitation sources per terminal:2 simplex; 4 TMR
-
Servo current selection span:10-120 mA
-
LVDT excitation, matched path:7.00 +/-0.14 V rms
-
LVDT excitation frequency:3.2 +/-0.2 kHz
-
Servo sampling, matched path:200 Hz
-
Servo conversion resolution:12 bit
-
LVDT conversion resolution:14 bit
-
Servo accuracy, matched path:2%
-
LVDT accuracy, matched path:1%
-
LVDT/R maximum two-way lead resistance:15 ohm
-
LVDT/R maximum stated distance:300 m
-
Loaded excitation distortion:Less than 1% THD
Information
- General Electric IS200TSVOH1BDC carries the actuator-side coil and displacement-feedback wiring; the selected coil resistance and termination jumpers establish the electrical load seen by VSVO.
Feedback topology: Four-wire LVDT and three-wire LVDR use different field connections.
Trip connection: The installed JD1 clamp path is separate from normal valve positioning.
Valve position can be returned by a four-wire LVDT or a three-wire LVDR. The excitation source floats relative to signal common, while the measured feedback is converted and checked in the processor. Preserve the actual winding connections and approved stroke direction; a typical increase in RMS feedback is not a universal rule for every valve installation.
In the applicable simplex trip arrangement, TREG J1 connects to TSVO JD1 to clamp the servo on turbine trip. This path and the coil shorting function have a different purpose from ordinary position control. A successful stroke test therefore cannot replace the site-approved trip/clamp proof.
-
General Electric IS200TSVOH1BDC official technical excerpt
Original GEH-6421H system-architecture pages for the servo termination and trip architecture. PDF, 3 pages. -
General Electric IS200TSVOH1BDC engineering guide
Apter Power field guide: coil-resistance selection, floating excitation and trip-clamp proof. PDF, 2 pages.
Integration boundary: Select coil jumpers from both resistance and current requirements; keep sensor excitation and trip-clamp circuits identified separately.
-
Simplex actuator wiring
Match the documented simplex coil/current combination and its field return before energizing an output. -
TMR coil termination
Use the redundant coil arrangement and its associated load selection rather than transferring a simplex jumper pattern. -
LVDT or LVDR feedback
Land the correct number of sensor conductors and preserve the calibrated minimum/maximum stroke relationship. -
Trip-clamp restoration
Reinstate the simplex TREG-to-JD1 clamp circuit when it forms part of the installed shutdown design.
Compare winding resistance with the selected current and architecture before copying terminal jumper positions.
Do not add a signal-common bond to the LVDT/R excitation without the approved wiring basis.
Record feedback at the approved end positions before dismantling the connection; some applications reverse the usual RMS progression.
Apply the 300 m route allowance together with the maximum 15 ohm two-way resistance for LVDT/R wiring.
Test the JD1 trip interface under the approved shutdown procedure, independently of normal servo command following.
Prove each coil/feedback assignment separately so crossed loop wiring is not masked by an apparently moving valve.
Alternative Names
Technical notes
Coil-selection example: The 120 mA selections distinguish a 40 ohm simplex coil from a 75 ohm TMR coil; the current label alone does not establish the proper jumper configuration.
Excitation quality: The matched LVDT/R source is specified with less than 1% loaded harmonic distortion; evaluate waveform quality as well as RMS amplitude during feedback diagnosis.
Feedback common mode: The floating excitation supports the stated common-mode allowance up to 35 V DC or 35 V RMS at 50/60 Hz; this is not permission to apply that voltage as the sensor excitation.
FAQ View All FAQ
-
Why can IS200TSVOH1BDC need a different setting for two 40 mA coils?The standard table associates 62 ohms with simplex and 89 ohms with TMR at that current. Match the measured winding and architecture to the complete table rather than selecting on nominal mA alone.
-
Can the typical feedback endpoints be used as calibration setpoints for IS200TSVOH1BDC?The typical LVDT/R RMS endpoints can be reversed in some applications. Establish the valve-specific mechanical endpoints and approved configuration, then verify feedback direction before closing the loop.
-
Why can an LVDT signal on IS200TSVOH1BDC change after adding a common wire?Its excitation is intentionally floating. Review the added bond, sensor topology and approved return path; an unintended common can alter the measurement reference even when the RMS amplitude remains plausible.
-
How should IS200TSVOH1BDC be checked when the valve moves correctly but fails the shutdown proof?Trace the installed TREG/JD1 clamp connection and output shorting path separately from command tracking. Verify the intended protective action under the machine shutdown procedure without treating ordinary movement as trip evidence.
-
Can the number of excitation sources on IS200TSVOH1BDC be assumed identical in simplex and TMR?The documented terminal arrangement uses two sources for simplex and four for TMR. Confirm the architecture and actual sensor assignment before interpreting a spare excitation connection as a missing circuit.
-
What makes an LVDT/R cable acceptable for IS200TSVOH1BDC at the maximum route length?It must also satisfy the maximum two-way resistance and retain the intended conductor arrangement. Measure the installed path including connections; distance alone does not prove excitation and feedback integrity.
-
How can crossed feedback windings at IS200TSVOH1BDC be detected before enabling the servo?With motion safely controlled, compare each named feedback channel with the corresponding valve position while the other loop remains fixed. Record both channel assignment and direction before restoring closed-loop authority.
-
Does IS200TSVOH1BDC require every non-standard coil to be rejected?The manufacturer describes non-standard selection by matching the total resistance, including an 80 mA, 125 ohm example using setting 120B. Such a selection requires the applicable coil-table engineering calculation, not a copied standard jumper pattern.
Supporting new and legacy automation
-
Please try to be as accurate as possible with your search.
-
We can quote you on 1000s of specialist parts, even if they are not listed on our website.
-
We can't find any results for “”.
Related cases and sourcing guidance
View all case studiesYou May Also Like
Product Browsing History
-
Whatsapp: +86 18030235313
Send us a message. -
sales13@apterpower.com
Complete our online form. -
+86 18030235313
Speak to our team in your native language.