Speak to a sourcing specialist
sales13@apterpower.com

IS200ECTBG2ADE

Exciter Contact Terminal Board
Product image is representative; revision or series may vary. Contact us to request a specific version.

Product Describe:

GE IS200ECTBG2ADE is the EX2100 simplex contact terminal board, combining customer auxiliary contacts, generator status inputs and relay/trip outputs at the EMIO interface.
  • Manufacturer part number
    IS200ECTBG2ADE
  • Shipping
    Swift global dispatch
  • Condition
    New, original product
  • Shipping size (est.)
    33cm x 17.7cm x 5.5cm
  • Country of Origin
    USA
Get a quick price for IS200ECTBG2ADE
E-mail *
Mobile
Company
Content *
Quantity *
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)
For more information on how your data is processed and stored by Apterpower please read our privacy policy

What happens after you enquire

  • 0

    Review your reference

    Send the full marking, quantity and label photos. We review the item and any version details that need clarification.

  • 1

    Confirm the offer

    Check the quoted reference, condition, included items and expected dispatch date before approving your order.

  • 2

    Arrange dispatch

    Confirm delivery details and receive the tracking number when it becomes available.

  • Match the complete marking

    Include IS200ECTBG2ADE and every revision or approval marking visible on the item. Keep the exact reference on your enquiry and quotation.

  • Check the offered item before ordering

    Request available label and interface photos. Have your maintenance team compare the offered IS200ECTBG2ADE reference with the installed equipment and applicable GE documentation.

Technical specifications for IS200ECTBG2ADE

  • Manufacturer:
    General Electric
  • Product Category:
    Gas Turbine Control
  • Spare Part Number:
    IS200ECTBG2ADE
  • Weight:
    0.66 kg
  • General-purpose contact inputs:
    6
  • Dedicated status inputs:
    2
  • Contact-wetting voltage:
    70 V DC
  • General-purpose Form C outputs:
    4
  • Trip contact outputs:
    2
  • Relay customer supply, nominal:
    125 V DC
  • Relay customer supply, minimum:
    24 V DC
  • Resistive breaking current at 28 V DC:
    2 A
  • Resistive breaking current at 125 V DC:
    0.5 A
  • Inductive breaking current at 28 V DC:
    1 A; L/R 0.007 s
  • Inductive breaking current at 125 V DC:
    0.1 A; L/R 0.007 s

Information

Overview Downloads Applications / Compatibility Product Precautions
  • ECTBG2 is the simplex execution. ECTBG1 fans inputs to three controllers and uses voted relay control; the G1 and G2 wiring architectures must not be treated as the same spare.
Generator-state handling: Dedicated lockout and online inputs remain separate from general-purpose contact duties.
Relay observability: Coil current and auxiliary-contact status provide distinct feedback to the controller.
Simplex-specific routing: The G2 board carries the single-controller contact arrangement rather than the G1 redundant fan-out.
ECTBG2 receives six auxiliary contact inputs plus dedicated 86G and 52G status inputs. The 86G input is open for trip, while 52G is closed for online status. Keeping these functions explicit avoids replacing a protective or generator-state signal with an assumed general-purpose input.

The general-purpose Form C outputs are controlled by EMIO. Coil-current and auxiliary-contact feedback are returned to that controller, so relay diagnosis should distinguish the requested command from the contact result. The board also contains two trip-contact outputs for the customer lockout duty.

The relay breaking capability changes with voltage and load type. The published inductive figures include an L/R condition, and inductive-load suppression is provided externally by the customer. Retain that suppression and the customer contact supply when restoring a simplex EX2100 circuit.
Controller platform reference: EX2100 simplex contact I/O. Retain the documented GE configuration.
Prepare GE IS200ECTBG2ADE for its configured installation using these product-specific checks.
Isolate customer supplies

External relay-contact power remains a separate isolation source.

Preserve 86G logic

Check the open-for-trip relationship before returning protection to service.

Keep 52G identity

Confirm the online status source and its closed-online behavior.

Retain suppression

Inspect the customer-provided suppression on inductive loads.

Compare load at voltage

Use the breaking limit for the actual supply and L/R condition.

Prove relay feedback

Compare coil command, auxiliary status and the actual switched circuit.

Alternative Names

GE IS200ECTBG2ADE

Technical notes

Group distinction: G2 is simplex; G1 uses three-controller fan-out and voted relay control.

Load interpretation: The inductive break-current values depend on the stated L/R condition.

Trip-state acceptance: Check 86G with its open-for-trip interpretation separately from 52G closed-when-online status; a generic contact continuity result does not verify both plant states.

FAQ View All FAQ

  • Can IS200ECTBG2ADE be exchanged directly for an ECTBG1 redundant board?
    The group change is not established as a direct interchange. G1 fans inputs to three controllers and uses voted control, whereas G2 is simplex. Compare the rack architecture and cable routing first.
  • What is the consequence of reversing the 86G logic on IS200ECTBG2ADE?
    The dedicated input is open for trip. Reversing that relationship can misrepresent lockout status; prove the actual contact and controller interpretation before enabling normal operation.
  • Why should the 52G circuit of IS200ECTBG2ADE be checked independently of auxiliary contacts?
    52G supplies the generator online state and is closed when online. Confirm its terminal identity and physical status source rather than assigning it as a generic auxiliary input.
  • Does IS200ECTBG2ADE eliminate the need for external suppression on inductive loads?
    No. The published relay characteristics call for customer-provided external suppression. Retain its correct location and compare the actual inductive duty with the voltage-specific break limit.
  • How can a relay command and relay-status discrepancy on IS200ECTBG2ADE be investigated?
    Check coil-current feedback and auxiliary-contact status separately, then verify the customer supply and switched field circuit. A valid controller command does not prove the external load received power.
  • Can the 28 V DC breaking-current value of IS200ECTBG2ADE be used for a 125 V DC circuit?
    No. The manufacturer gives different current limits at those voltages and for resistive versus inductive loads. Select the applicable row and preserve the specified L/R condition.
  • Why can an auxiliary-input test pass while generator status remains wrong on IS200ECTBG2ADE?
    The six general-purpose inputs are distinct from dedicated 86G and 52G duties. Trace the lockout and breaker-status contacts to their assigned terminals, then prove open-for-trip and closed-when-online interpretation at the controller.
  • How should an intermittent inductive-output fault be assessed on IS200ECTBG2ADE?
    Compare customer supply and contact-side behavior at switching, inspect the external suppression circuit, and check the voltage-specific break current with the stated L/R condition. A steady-state continuity test alone does not represent an inductive interruption.
Manufacturers

Product Browsing History

Revisit the products you recently viewed on Apter Power.
SPEAK TO OUR TEAM
Let’s find the right solution for you.
Send us the part number, quantity and delivery destination. Our team will help confirm availability and lead time.
  • Whatsapp: +86 18030235313

    Send us a message.
  • sales13@apterpower.com

    Complete our online form.
  • +86 18030235313

    Speak to our team in your native language.