Speak to a sourcing specialist
sales13@apterpower.com

IS200EDCFG1AED

Exciter DC Feedback Board
Product image is representative; revision or series may vary. Contact us to request a specific version.

Product Describe:

GE IS200EDCFG1AED measures generator field current and bridge DC voltage for EX2100, sending the two feedback quantities to EISB through an isolating fiber-optic path.
  • Manufacturer part number
    IS200EDCFG1AED
  • Shipping
    Swift global dispatch
  • Condition
    New, original product
  • Shipping size (est.)
    22.8cm x 15.1cm x 3.5cm
  • Country of Origin
    USA
Get a quick price for IS200EDCFG1AED
E-mail *
Mobile
Company
Content *
Quantity *
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)
For more information on how your data is processed and stored by Apterpower please read our privacy policy

What happens after you enquire

  • 0

    Review your reference

    Send the full marking, quantity and label photos. We review the item and any version details that need clarification.

  • 1

    Confirm the offer

    Check the quoted reference, condition, included items and expected dispatch date before approving your order.

  • 2

    Arrange dispatch

    Confirm delivery details and receive the tracking number when it becomes available.

  • Match the complete marking

    Include IS200EDCFG1AED and every revision or approval marking visible on the item. Keep the exact reference on your enquiry and quotation.

  • Check the offered item before ordering

    Request available label and interface photos. Have your maintenance team compare the offered IS200EDCFG1AED reference with the installed equipment and applicable GE documentation.

Technical specifications for IS200EDCFG1AED

  • Manufacturer:
    General Electric
  • Product Category:
    Gas Turbine Control
  • Spare Part Number:
    IS200EDCFG1AED
  • Weight:
    0.24 kg
  • Nominal shunt signal:
    100 mV
  • Current-channel amplifier range:
    -5 to +5 V
  • Feedback frequency range:
    0 to 2 MHz
  • Feedback accuracy:
    1% of full scale
  • Bridge-voltage selector settings:
    7
  • External supply rails:
    +24 V DC / -24 V DC
  • Internal regulated rails:
    +15 V DC / -15 V DC / +5 V DC

Information

Overview Downloads Applications / Compatibility Product Precautions
  • EDCF is the DC bridge-feedback board. EACF measures the exciter AC supply instead; its voltage groups and copper I/O arrangement must not be transferred to this EDCF reference.
Noise-resistant feedback: Optical transmission separates high-energy bridge measurement from the controller interface.
Independent measured quantities: Shunt-derived current and scaled bridge voltage follow distinct signal paths.
Application-selected scaling: The installed bridge setting governs the interpretation of voltage feedback.
Current feedback starts at the DC shunt at the power-converter output. Its low-level differential signal is amplified and converted into a proportional frequency before optical transmission. The nominal shunt signal describes the documented measurement arrangement; it is not permission to connect an arbitrary higher shunt output.

Voltage feedback is taken across the bridge output and scaled by the application-selected resistor/jumper arrangement. The seven settings belong to bridge-voltage scaling, whereas the controller must interpret the resulting feedback against the installed excitation configuration. A plausible signal can still represent an incorrect scale.

The EDCF and EISB communicate across a fiber-optic isolation boundary. Keep the high-energy voltage and shunt connections distinct from the control-side optical receivers and the external bipolar supply. After restoring the channel, compare current and voltage with approved independent references and the recorded operating condition.
Controller platform reference: EX2100 DC field feedback. Retain the documented GE configuration.
The technical reference covers EX2100 DC field feedback. The independent field guide develops dc shunt, bridge scaling and optical channel proof.
The technical reference retains selected original manufacturer pages. The separate installation guide supports field verification for IS200EDCFG1AED.
Prepare GE IS200EDCFG1AED for its configured installation using these product-specific checks.
Control the bridge boundary

Use the approved field-circuit isolation procedure before touching shunt or voltage connections.

Record selector positions

Capture the actual voltage-scaling selection before the board is removed.

Retain shunt polarity

Identify both differential shunt leads and their circuit destination.

Separate the fibers

Tag voltage and current optical paths at both ends.

Check bipolar supply

Confirm both external supply rails with respect to the documented reference.

Verify against a reference

Compare restored feedback with approved independent measurements before control release.

Alternative Names

GE IS200EDCFG1AED

Technical notes

Nominal versus maximum: The documented 100 mV shunt signal is a nominal operating value.

Measurement separation: Current derives from the DC shunt; voltage uses the bridge-scaling network.

Two-channel fault isolation: Use current sign and magnitude to assess the shunt path, and an independent voltage reference to assess bridge scaling. A common adjustment cannot diagnose both paths.

FAQ View All FAQ

  • Can IS200EDCFG1AED replace an EACF AC-feedback board?
    No. EDCF measures DC field current and bridge voltage, while EACF measures the exciter AC supply. Compare the measured quantity and interface before considering any spare.
  • Does the nominal shunt signal of IS200EDCFG1AED define its maximum allowed input?
    No maximum input rating is established by that nominal figure. Preserve the installed shunt and approved scaling relationship rather than increasing the shunt signal from this value alone.
  • Why can IS200EDCFG1AED return a stable voltage reading with the wrong engineering value?
    The bridge-voltage selector and receiving configuration determine scaling. Compare the saved selector setting and controller interpretation with an approved independent voltage reference.
  • How should crossed optical channels on IS200EDCFG1AED be ruled out?
    Trace the voltage and current fibers from their board outputs to the assigned EISB receivers. Confirm each channel using the relevant quantity and test condition rather than relying on cable appearance.
  • What should be checked when both feedback quantities disappear from IS200EDCFG1AED?
    Review the bipolar supply, common board connections and optical routing first. Distinguish a shared supply/interface problem from separate shunt and bridge-voltage faults.
  • Can optical communication from IS200EDCFG1AED make its bridge connections safe to touch?
    No. The optical link isolates the controller path; it does not remove hazardous energy at the bridge, shunt or voltage connections. Use the approved field-circuit isolation procedure.
  • Why does a live optical signal not by itself validate the measurement from IS200EDCFG1AED?
    The pulse stream must reach the correct receiver and be interpreted with the installed engineering scale. Compare current and bridge voltage separately with approved references; optical activity alone does not establish quantity, polarity or calibration.
  • What should be checked before correcting a persistent offset on IS200EDCFG1AED in software?
    Compare the approved shunt relationship, voltage-selector position, bipolar supply and fiber destinations with the retained configuration. Establish which quantity is wrong before changing application scaling; otherwise a wiring or selection error may be hidden.