Product Describe:

GE MIVII1000E00HI00 is a configurable MIV II voltage protection relay for an engineered power-system protection panel. Its selected input and auxiliary-supply ranges must match the installed sensing and control circuits.
  • Manufacturer part number
    MIVII1000E00HI00
  • Shipping
    Swift global dispatch
  • Condition
    New, original product
  • Shipping size (est.)
    15.8cm × 26.7cm × 18cm
  • Country of Origin
    USA
Get a quick price for MIVII1000E00HI00
E-mail *
Mobile
Company
Content *
Quantity *
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)
For more information on how your data is processed and stored by Apterpower please read our privacy policy

What happens after you enquire

  • 0

    Review your reference

    Send the full MIVII1000E00HI00 marking, required quantity and current label photos. We review the voltage-input and auxiliary-supply selection and clarify any revision details.

  • 1

    Confirm the offer

    Check the quoted MIVII1000E00HI00 reference, New, original product condition, included items and expected dispatch date before approving the order.

  • 2

    Arrange dispatch

    Confirm the delivery details for MIVII1000E00HI00 and receive the tracking number when it becomes available.

  • Match the complete marking

    Include MIVII1000E00HI00 and any revision or assembly marking visible on the relay. Keep the exact reference on your enquiry and quotation.

  • Check the offered item before ordering

    Request current front, rear, terminal and identification-label photos. Have your protection engineer compare the offered MIVII1000E00HI00 with the installed wiring, supply selection and approved settings.

Technical specifications for MIVII1000E00HI00

  • Manufacturer:
    General Electric
  • Product Category:
    General Automation
  • Spare Part Number:
    MIVII1000E00HI00
  • Weight:
    2.76 kg
  • Tariff Code:
    8537101190
  • Relay family:
    MIV II
  • Protection execution:
    MIV II 1000 voltage functions
  • Voltage-input option:
    10–250 V
  • High-range auxiliary supply:
    110–250 V dc or 110–230 V ac nominal
  • Supply operating range:
    88–300 V dc or 88–264 V ac
  • Power demand:
    15 W maximum
  • Front service interface:
    RS-232
  • Rear communication:
    RS-485, Modbus RTU
  • Local display:
    Two-line, 16-character LCD
  • Output relays:
    Six Form-C contacts

Information

Overview Downloads Applications / Compatibility Product Precautions
  • GE MIVII1000E00HI00 monitors a dedicated voltage-transformer circuit and makes its programmed protection decisions available to the panel through relay contacts and local indications.
Protection role: Voltage-dependent alarm and trip logic
Service access: Local display and front engineering port
Integration boundary: Configured sensing, outputs and host protocol
The MIV II 1000 execution applies programmable voltage protection to the measured circuit. An engineer sets pickup, delay and output mapping for the protected equipment, then tests the complete trip path as part of the panel commissioning record.

The selected voltage input is the 10–250 V option. The HI auxiliary supply accepts the documented high-range dc or ac supply; these are different circuits and must not be interchanged with the measurement input. Local indications and relay outputs support panel operation and alarm or trip integration.

Front RS-232 is used for service access, while the rear RS-485 port supports a configured Modbus RTU link. Preserve the existing settings, communications address, event records and wiring map during replacement, then verify protection elements and output operation against the approved study.
Controller platform reference: GE MIV II protection relay family. Match the installed configuration and interfaces.
GE MIVII1000E00HI00 technical downloads. The technical reference explains the selected voltage input, auxiliary supply, protection outputs and communication ports. The installation guide covers wiring review, settings transfer and secondary-injection acceptance.
Select and commission MIVII1000E00HI00 against the exact nameplate, approved protection study and installed sensing and supply circuits.
Installation and commissioning checks for General Electric MIVII1000E00HI00.
Separate the two voltage circuits

Trace the voltage-transformer input separately from the relay auxiliary supply before wiring.

Capture settings

Save element thresholds, timing, logic, output assignments and communications parameters.

Check transformer polarity

Confirm the installed measurement wiring and burden under the protection drawing.

Inspect trip contacts

Verify contact ratings and the actual alarm or trip circuit before energization.

Test the communications path

Confirm rear-port wiring, address and Modbus polling after the change.

Prove the protection chain

Use approved secondary injection to check pickup, delay, indication and the intended output contacts.

Alternative Names

MIV II 1000E00HI00

Technical notes

Input coordination: Set voltage thresholds and delays to the approved protection study, including the installed transformer ratio.

Output verification: Prove contact assignments at the panel wiring, including the downstream alarm and trip paths.

Technical reference: GE Vernova MIV II Digital Voltage and Frequency Relay brochure; 1000/E/0/HI selections apply as stated in the parameter table.

FAQ View All FAQ

  • Which protection-setting records should accompany MIVII1000E00HI00 replacement?
    Retain the approved settings file, coordination study, input ratio, logic map and as-found test report.
  • How can a false undervoltage indication on MIVII1000E00HI00 be isolated?
    Compare the transformer secondary voltage at the input terminals with the configured nominal value, wiring polarity and element timing.
  • What distinguishes the HI supply selection on MIVII1000E00HI00 from the voltage input?
    HI identifies the relay auxiliary power option; the separate 10–250 V selection applies to the measured voltage input.
  • What should be checked if MIVII1000E00HI00 does not communicate over Modbus RTU?
    Check the rear RS-485 pair, termination, node address, serial format and host polling before changing relay hardware.
  • How should the output contacts on MIVII1000E00HI00 be proved?
    Use the site-approved test plan to verify each assigned alarm or trip contact and the downstream circuit response.
  • Can an MIV II frequency-only configuration replace MIVII1000E00HI00?
    Only after the full order code, sensing inputs, protection functions and approved settings are confirmed compatible.
  • How are event records on MIVII1000E00HI00 useful during commissioning?
    Compare timestamps and element actions with the applied test sequence and panel indications.
  • What should be documented after secondary injection of MIVII1000E00HI00?
    Record applied voltage, pickup and reset points, measured delays, output actions and final settings revision.