Match the complete marking
Include MIVII1000E00HI00 and any revision or assembly marking visible on the relay. Keep the exact reference on your enquiry and quotation.
-
Check the offered item before ordering
Request current front, rear, terminal and identification-label photos. Have your protection engineer compare the offered MIVII1000E00HI00 with the installed wiring, supply selection and approved settings.
Technical specifications for MIVII1000E00HI00
-
Manufacturer:General Electric
-
Product Category:General Automation
-
Spare Part Number:MIVII1000E00HI00
-
Weight:2.76 kg
-
Tariff Code:8537101190
-
Relay family:MIV II
-
Protection execution:MIV II 1000 voltage functions
-
Voltage-input option:10–250 V
-
High-range auxiliary supply:110–250 V dc or 110–230 V ac nominal
-
Supply operating range:88–300 V dc or 88–264 V ac
-
Power demand:15 W maximum
-
Front service interface:RS-232
-
Rear communication:RS-485, Modbus RTU
-
Local display:Two-line, 16-character LCD
-
Output relays:Six Form-C contacts
Information
- GE MIVII1000E00HI00 monitors a dedicated voltage-transformer circuit and makes its programmed protection decisions available to the panel through relay contacts and local indications.
Service access: Local display and front engineering port
Integration boundary: Configured sensing, outputs and host protocol
The selected voltage input is the 10–250 V option. The HI auxiliary supply accepts the documented high-range dc or ac supply; these are different circuits and must not be interchanged with the measurement input. Local indications and relay outputs support panel operation and alarm or trip integration.
Front RS-232 is used for service access, while the rear RS-485 port supports a configured Modbus RTU link. Preserve the existing settings, communications address, event records and wiring map during replacement, then verify protection elements and output operation against the approved study.
-
GE MIVII1000E00HI00 technical reference
2-page reference on MIV II 1000 voltage protection, selected input and HI supply ranges, relay contacts and service communication. -
GE MIVII1000E00HI00 installation verification guide
1-page engineering guide for circuit segregation, settings backup, injection tests, output proof and handover evidence.
Panel integration: The measured-voltage circuit, auxiliary supply, output wiring and communications settings form one approved protection scheme.
-
Generator and transformer panels
Apply voltage protection where the approved single-line and relay-setting study call for MIV II 1000 functions. -
Bus voltage supervision
Monitor the designated sensing circuit and coordinate alarm or trip thresholds with other protection devices. -
SCADA integration
Expose configured indications and events over the documented rear RS-485 Modbus RTU interface. -
Existing-relay replacement
Use the same voltage-input and auxiliary-supply selections, and restore the validated settings file and terminal mapping.
Trace the voltage-transformer input separately from the relay auxiliary supply before wiring.
Save element thresholds, timing, logic, output assignments and communications parameters.
Confirm the installed measurement wiring and burden under the protection drawing.
Verify contact ratings and the actual alarm or trip circuit before energization.
Confirm rear-port wiring, address and Modbus polling after the change.
Use approved secondary injection to check pickup, delay, indication and the intended output contacts.
Alternative Names
Technical notes
Input coordination: Set voltage thresholds and delays to the approved protection study, including the installed transformer ratio.
Output verification: Prove contact assignments at the panel wiring, including the downstream alarm and trip paths.
Technical reference: GE Vernova MIV II Digital Voltage and Frequency Relay brochure; 1000/E/0/HI selections apply as stated in the parameter table.
FAQ View All FAQ
-
Which protection-setting records should accompany MIVII1000E00HI00 replacement?Retain the approved settings file, coordination study, input ratio, logic map and as-found test report.
-
How can a false undervoltage indication on MIVII1000E00HI00 be isolated?Compare the transformer secondary voltage at the input terminals with the configured nominal value, wiring polarity and element timing.
-
What distinguishes the HI supply selection on MIVII1000E00HI00 from the voltage input?HI identifies the relay auxiliary power option; the separate 10–250 V selection applies to the measured voltage input.
-
What should be checked if MIVII1000E00HI00 does not communicate over Modbus RTU?Check the rear RS-485 pair, termination, node address, serial format and host polling before changing relay hardware.
-
How should the output contacts on MIVII1000E00HI00 be proved?Use the site-approved test plan to verify each assigned alarm or trip contact and the downstream circuit response.
-
Can an MIV II frequency-only configuration replace MIVII1000E00HI00?Only after the full order code, sensing inputs, protection functions and approved settings are confirmed compatible.
-
How are event records on MIVII1000E00HI00 useful during commissioning?Compare timestamps and element actions with the applied test sequence and panel indications.
-
What should be documented after secondary injection of MIVII1000E00HI00?Record applied voltage, pickup and reset points, measured delays, output actions and final settings revision.
Supporting new and legacy automation
-
Please try to be as accurate as possible with your search.
-
We can quote you on 1000s of specialist parts, even if they are not listed on our website.
-
We can't find any results for “”.
Related cases and sourcing guidance
View all case studiesYou May Also Like
Product Browsing History
-
MIVII1000E00HI00Product Details -
IS220PTCCH2BProduct Details -
IS420ESWBH3AXProduct Details -
IS200STTCH2AProduct Details -
531X123PCHACG1Product Details -
IS220STAOH2AProduct Details -
IS200TBAIH1CDDProduct Details -
531X303MCPBCG1Product Details -
8121-DI-DC-01Product Details -
DS200SLCCG1AFGProduct Details
-
Whatsapp: +86 18030235313
Send us a message. -
sales13@apterpower.com
Complete our online form. -
+86 18030235313
Speak to our team in your native language.