IS200TBAIH1CDD

Analog Input/Output Terminal Board
Product image is representative; revision or series may vary. Contact us to request a specific version.

Product Describe:

This Mark VI terminal board connects analog field circuits to a VAIC processor. Its H1C generation is the documented partner for VAICH1D-or-later hardware, which changes the supported 20 mA output loading compared with the earlier terminal generation.
  • Manufacturer part number
    IS200TBAIH1CDD
  • Shipping
    Swift global dispatch
  • Condition
    New, original product
  • Shipping size (est.)
    33cm x 10cm x 2.5cm
  • Country of Origin
    USA
Get a quick price for IS200TBAIH1CDD
E-mail *
Mobile
Company
Content *
Quantity *
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)
For more information on how your data is processed and stored by Apterpower please read our privacy policy

What happens after you enquire

  • 0

    Review your reference

    Send the full marking, quantity and label photos. We review the item and any version details that need clarification.
  • 1

    Confirm the offer

    Check the quoted reference, condition, included items and expected dispatch date before approving your order.
  • 2

    Arrange dispatch

    Confirm delivery details and receive the tracking number when it becomes available.
  • Match the complete marking

    Include IS200TBAIH1CDD and every hardware or assembly-revision marking visible on the item. Keep the exact reference on your enquiry and quotation.
  • Check the offered item before ordering

    Request available label and interface photos. Have your maintenance team compare the offered IS200TBAIH1CDD reference with the installed equipment and applicable General Electric documentation.

Technical specifications for IS200TBAIH1CDD

  • Manufacturer:
    General Electric
  • Product Category:
    Gas Turbine Control
  • Spare Part Number:
    IS200TBAIH1CDD
  • Weight:
    0.3 kg
  • Tariff Code:
    8537101190
  • Analog inputs:
    10
  • Analog outputs:
    2
  • Processor connectors:
    3 x DC-37
  • Current input selections:
    4-20 mA; +/-1 mA
  • Voltage input selections:
    +/-5 V; +/-10 V
  • Output 1 selections:
    0-20 mA; 0-200 mA
  • Output 2 range:
    0-20 mA
  • 20 mA load, matched later generation:
    800 ohm
  • 200 mA load:
    50 ohm
  • Transducer supply current:
    21 mA continuous per connection
  • Transducer supply voltage:
    24 V DC
  • Available later-generation output drive:
    Up to 18 V at terminals

Information

Overview Downloads Applications / Compatibility Product Precautions
  • General Electric IS200TBAIH1CDD separates field-loop conditioning from rack conversion, allowing the terminal settings to be checked before a VAIC channel is condemned.
Generation match: H1C termination pairs with VAICH1D or later.
Loop selection: Current/voltage jumpers must agree with the transmitter circuit.
Redundant wiring: JR1, JS1 and JT1 carry separate processor paths.
The H1C interface in IS200TBAIH1CDD serves the later VAIC generation. Earlier VAICH1C-and-before processing uses TBAIH1B-or-earlier or DTAI; later VAICH1D processing uses TBAIH1C-or-later or STAI. This is a functional pairing boundary, so a terminal replacement must preserve the processor generation as well as the field-terminal numbering.

The transmitter input type is established at the termination. Eight inputs per TBAI provide voltage or 4-20 mA selection, while two additional circuits support 4-20 mA or the low-current range. The field source, its power arrangement and the terminal jumper must be reconciled before software scaling is applied; changing engineering units cannot correct the wrong electrical input circuit.

In simplex service JR1 provides the rack connection. TMR adds JS1 and JT1, distributes each input to the three VAICs, and diode-ORs transducer power from the racks. The current outputs use processor feedback and median-current operation, so measuring only one disconnected processor leg does not establish the complete loop output.
Controller platform reference: GE Mark VI VAIC analog I/O. Match the terminal and processor generations.
Separate transmitter power, selected input circuits and the load-connected output before restoring terminal authority.
De-energize the field path

Isolate external transmitter supplies as well as the rack before disturbing the TBAI terminals.

Record electrical selectors

Save the actual jumper positions by channel, distinguishing the eight general inputs from the two low-current-capable inputs.

Separate output ranges

Verify the selectable first output independently of the second 20 mA output before attaching a receiver.

Keep returns traceable

Identify signal return and transducer power return before moving conductors; a correct signal number does not establish its return path.

Restrain rack cables

Seat and latch each DC-37 connection in its recorded JR1/JS1/JT1 location without transferring cable load to the connector.

Check the complete loaded loop

Measure actual current with the receiver connected and compare it with command and channel feedback before removing the isolation.

Alternative Names

GE IS200TBAIH1CDD General Electric IS200TBAIH1CDD

Technical notes

Transducer power: The 21 mA continuous limit applies to an individual transducer-supply connection, not to the selectable 200 mA analog output.

Burden calculation: An 800 ohm receiver at 20 mA uses 16 V. The later pair provides up to 18 V at the terminals; wire and connection losses must remain within the available margin.

Terminal identification: The read-only ID includes board type, revision, serial identity and connector location, allowing a cable-location mismatch to be distinguished from a bad transmitter.

FAQ View All FAQ

  • Why can IS200TBAIH1CDD report hardware incompatibility after a cable exchange?
    VAIC interrogates the termination ID and connector location. Compare the diagnosed JR/JS/JT location with the cable labels and rack destination before replacing an analog component.
  • How can the current-conversion path of IS200TBAIH1CDD be checked without changing engineering scaling?
    For the documented 4-20 mA circuit, the 250 ohm conversion resistor gives 1-5 V across that path. With the loop isolated for the approved test, compare injected current and the corresponding conversion voltage before adjusting software scale; a wrong electrical selection cannot be corrected by changing displayed units.
  • How should a current input on IS200TBAIH1CDD be tested when a voltage source gives a plausible reading?
    Identify whether the channel uses the current-conversion circuit or the voltage circuit, then inject the intended electrical quantity with the loop isolated. A plausible scaled value from the wrong source is not an input-type acceptance test.
  • Why can one rack lose a measurement through IS200TBAIH1CDD while the other two remain healthy?
    In TMR the three processor-cable paths are separate even though the field signal is shared. Compare rack-specific readings and the affected cable connection before opening the common field loop.
  • What does a transducer-supply short on IS200TBAIH1CDD mean for output troubleshooting?
    Treat the protected transmitter supply separately from current-output regulation. Check the transmitter branch for a short and verify the receiver loop independently rather than assuming both use the same current limit.
  • How can IS200TBAIH1CDD be accepted with an externally powered transmitter?
    Confirm the approved common/return relationship and electrical range, then exercise the transmitter or an isolated source at low, middle and high points. Record both the physical signal and the VAIC engineering value.
  • Why can TMR output current through IS200TBAIH1CDD differ from a measurement on one processor leg?
    The connected output is formed by the redundant drive and feedback arrangement. Evaluate the actual field-loop current and the individual VAIC diagnostics together; a disconnected leg is not a representative load condition.
  • What should be recorded if IS200TBAIH1CDD develops a range-dependent error?
    Capture the selected input/output circuit, actual source or receiver value, field-loop loading and corresponding rack reading at several points. A repeatable gain error calls for range/scaling review, whereas a load-dependent output collapse calls for loop-burden investigation.