Speak to a sourcing specialist
sales13@apterpower.com

16710-09

Armored Accelerometer Interconnect Cable
Product image is representative; revision or series may vary. Contact us to request a specific version.

Product Describe:

Bently Nevada 16710-09 is a 9 ft armored accelerometer interconnect cable for 330400 and 330425 transducer installations. Its three shielded conductors join a three-socket plug to terminal lugs.
  • Manufacturer part number
    16710-09
  • Shipping
    Swift global dispatch
  • Condition
    New, original product
  • Shipping size (est.)
    27cm x 27cm x 2.5cm
  • Country of Origin
    USA
Get a quick price for 16710-09
E-mail *
Mobile *
Company
Content *
Quantity *
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)
For more information on how your data is processed and stored by Apterpower please read our privacy policy

What happens after you enquire

  • 0

    Review your reference

    Send the complete Bently Nevada 16710-09 marking, installed accelerometer identity, channel drawing and cable-route details.

  • 1

    Confirm the offer

    Confirm the actual 9 ft cable, three-socket plug, terminal lugs and condition against available-unit photos and the written quotation.

  • 2

    Arrange dispatch

    Agree the itemized supply scope, packing and dispatch date after the cable identity and receiving instructions are confirmed.

  • Match the complete marking

    Include 16710-09 and the marking visible on the cable assembly. Keep the exact reference on your enquiry and quotation.

  • Check the offered item before ordering

    Request available plug, terminal-lug and label photos. Have your maintenance team compare the offered 16710-09 with the installed accelerometer wiring and applicable Bently Nevada technical information.

Technical specifications for 16710-09

  • Manufacturer:
    Bently Nevada
  • Product Category:
    Machinery Monitoring Systems
  • Spare Part Number:
    16710-09
  • Weight:
    0.24 kg
  • Tariff Code:
    8537101190
  • Cable role:
    330400/330425 accelerometer interconnect
  • Ordered length:
    9 ft (2.74 m nominal)
  • Cable conductors:
    3, shielded
  • Conductor gauge:
    22 AWG (0.5 mm²)
  • External protection:
    Armored cable
  • Transducer-end interface:
    3-socket plug
  • Receiving-end interface:
    Terminal lugs
  • Length selection:
    AA in 1 ft (305 mm) increments
  • Allowed ordered length:
    3–99 ft (0.9–30 m)
  • Listed standard lengths:
    6, 8, 10, 12, 15, 17, 20, 25, 50, 99 ft
  • Length class:
    Permitted nonstandard ordered length
  • System context:
    330400 / 330425 accelerometers; verify connected receiving instrument

Information

Overview Downloads Applications / Compatibility Product Precautions
  • Bently Nevada 16710-09 carries an accelerometer signal from the machine-mounted transducer toward the receiving monitoring circuit. The ordered cable is an interconnect, not the sensing element.
Product type: Armored accelerometer interconnect cable
Connection path: 3-socket plug to terminal lugs
Order selection: 9 ft cable option
The 16710 cable connects a compatible 330400 or 330425 accelerometer to the field wiring or monitoring interface. Its shielded conductors and armor address the wiring path; transducer sensitivity and frequency response belong to the connected accelerometer and measurement system.

The 09 suffix selects 9 feet of ordered cable. This falls inside the manufacturer's 3–99 ft selectable range but is not one of the listed standard lengths. Confirm the installed route, connector access and terminal location before assigning the cable to a channel.

At replacement, trace the three conductors and shield against the instrument drawing. Verify the plug mates with the actual accelerometer and the lug ends match the assigned input, common and shield points; do not infer conductor allocation from a cable photograph alone.
Controller platform reference: 16710 armored accelerometer interconnect cable. Verify the installed arrangement before release.
Technical downloads for 16710-09: a Bently Nevada accelerometer interconnect reference excerpt and an Apter Power connection guide.
The 16710 cable ordering definition applies to the interconnect. Accelerometer sensitivity and monitoring performance belong to the connected transducer system.
System and supply context: Bently Nevada 16710-09 carries an accelerometer signal from the machine-mounted transducer toward the receiving monitoring circuit. The ordered cable is an interconnect, not the sensing element.

Application boundary: The applications below require a correctly selected installed channel and actual machine drawing; the offered component does not establish complete-system performance.
Before installing 16710-09, compare the complete marking and route with the machine and channel drawings. Isolate the machine and measurement circuit.
Match both cable ends

Verify the 3-socket plug on the transducer end and terminal lugs at the receiving end before disconnecting the old cable.

Respect the selected length

Measure the installed routing path; do not rely on the nominal order length as proof of available installation slack.

Protect the shield

Use the approved channel drawing for shield termination. Avoid undocumented changes that could introduce noise or ground loops.

Avoid armor damage

Keep the route clear of sharp edges, moving equipment and cable crush points; inspect the jacket after securing the cable.

Separate sensor ratings

Do not assign 330400/330425 sensitivity, g range or frequency limits to the passive interconnect cable.

Check the whole channel

Inspect plug seating, lug torque and monitor input assignment, then check the measured signal with the installed transducer.

Alternative Names

Bently Nevada 16710-09 Bently 16710-09

Technical notes

Connection relationship: The 9 ft ordered interconnect joins a compatible 330400/330425 accelerometer to terminal wiring through a three-socket plug and lugs.

Installation boundary: Conductor landing, shield treatment and route protection follow the installed channel drawing; accelerometer sensing ratings are separate.

Technical reference: Bently Nevada 330400 and 330425 Accelerometers, 141638 Rev. AB. The cable ordering definition is the applicable evidence for this part.

FAQ View All FAQ

  • How should the terminal lugs of 16710-09 be assigned during a channel replacement?
    Use the controlled wiring drawing and trace each conductor from the three-socket plug before terminating the lugs. Preserve the original channel input, common and shield arrangement, then perform continuity and signal checks; cable color alone is not an approved assignment.
  • Can 16710-09 replace a 330400 accelerometer simply because the cable plugs into it?
    No. This part is the interconnect cable. Keep the installed transducer and channel identity separate; compare the complete sensor and monitoring arrangement before changing the sensing element.
  • What should an engineer do if the routed length of 16710-09 leaves too little service slack?
    Recheck the machine route, entry hardware and connector service loop. The manufacturer's order structure permits 1 ft increments within its stated range; choose a suitable ordered length rather than stressing the plug or lugs.
  • How can a suspected open conductor in 16710-09 be isolated?
    Disconnect both ends under the site's isolation procedure, then test each conductor and shield end-to-end with the channel drawing. Inspect the armor exit and plug strain relief, and avoid interpreting a reading through the connected accelerometer as cable-only continuity.
  • What installation condition can make 16710-09 introduce noise despite a good continuity test?
    An incorrect shield termination, damaged shield, loose lug or routing near a disturbance source can affect the receiving signal. Compare the terminations and route with the approved measurement drawing, then review the channel noise with the system operating.
  • Can 16710-09 be treated as proof that the connected 330425 channel meets its accelerometer specifications?
    No. The cable order defines the lead construction and ends. Check the connected accelerometer model, mounting, input and total wiring arrangement against the manufacturer's separate system data before accepting channel performance.
  • What should be inspected if the plug of 16710-09 loosens during machine service?
    Inspect mating contacts, plug seating, transducer connector condition and cable strain relief. Correct mechanical routing before reconnecting, then confirm the monitored signal and record the repair.
  • How should 16710-09 be accepted after replacing an existing interconnect?
    Compare both endpoint identities with the machine drawing, verify conductor continuity and shield landing, secure the armored route without crush points, and check that the monitor receives a stable response from the installed accelerometer.
SPEAK TO OUR TEAM
Let’s find the right solution for you.
Send us the part number, quantity and delivery destination. Our team will help confirm availability and lead time.
  • Whatsapp: +86 18030235313

    Send us a message.
  • sales13@apterpower.com

    Complete our online form.
  • +86 18030235313

    Speak to our team in your native language.