Match the complete marking
Include AAI835-H00 S1 and every revision or approval marking visible on the item. Keep the exact reference on your enquiry and quotation. -
Check the offered item before ordering
Request available label and interface photos. Have your maintenance team compare the offered AAI835-H00 S1 reference with the installed equipment and applicable Yokogawa documentation.
Technical specifications for AAI835-H00 S1
-
Manufacturer:Yokogawa
-
Product Category:DCS Systems
-
Spare Part Number:AAI835-H00 S1
-
Weight:0.3 kg
-
Tariff Code:8537101190
-
Analog inputs:4 channels
-
Input signal:4–20 mA DC
-
Input current limit:25 mA
-
Input accuracy:±16 µA
-
Data update:10 ms
-
Powered input resistance:290 Ω at 20 mA; 450 Ω at 4 mA
-
Unpowered input resistance:≥500 kΩ
-
Transmitter voltage at 20 mA:≥15.0 V
-
Transmitter voltage at zero current:≤29.3 V
-
5 V supply consumption:360 mA maximum
-
24 V supply consumption:450 mA maximum
-
Temperature drift:±16 µA / 10°C
-
Field/system withstand:500 V AC, 1 minute
-
Channel/channel withstand:500 V AC, 1 minute; complete MIL cable assembly subject to cable rating
-
Analog outputs:4 channels
-
Output signal:4–20 mA DC
-
Output accuracy:±48 µA
-
Output load:0–750 Ω; 200–750 Ω at 60–70°C in a qualified remote node
-
Open-output threshold:<0.65 mA
Information
- A four-loop input/output allocation provides channel separation on both measurement and command paths.
Isolation boundary: Field/system and interchannel isolation are specified for the applicable connection assembly.
Output monitoring: Open-output detection supplements the commanded current; it does not prove actuator motion.
An input circuit supplies the measurement side of a control loop; an output circuit drives its receiving load. These paths have different accuracy and compliance requirements, so successful input calibration cannot be used to accept the output bank or its actuator wiring. Input accuracy is ±16 µA, whereas output accuracy is ±48 µA. Keep these error budgets separate when assessing a transmitter-to-actuator control loop rather than applying the input conversion limit to the complete path.
Output load includes the receiver and series wiring. In a qualified remote node at 60–70°C the documented minimum load rises, making a near-zero-ohm bench load unsuitable for representing every installed condition. The H00 identity itself must also be checked against the host environmental requirement. /B3A00 identifies ATB3A-00 and /K4A00 identifies ATK4A-00. The specified output load is 0–750 Ω under the applicable normal installation conditions; qualified remote operation at 60–70°C changes the minimum to 200 Ω.
-
Yokogawa AAI835-H00 S1 official technical excerpt
Original legacy electrical data and H00/H03 suffix selection for the applicable FIO module. PDF, 2 pages. -
Yokogawa AAI835-H00 S1 engineering guide
Apter Power engineering guide for CENTUM FIO analog I/O. Allocate measurement and command terminals separately, retaining the documented output-load conditions. PDF, 3 pages.
Integration boundary: Allocate measurement and command terminals separately, retaining the documented output-load conditions. For the isolated mixed-I/O termination, recover both the input transmitter-power settings and output receiver allocation. AAI841 doubles the input/output count but uses non-isolated circuits, so it changes more than terminal density.
-
Four-loop control interfaces
Pair current measurements and commands in the project while keeping the input and output assignments distinct. -
Separated output receivers
The isolated architecture is relevant where receiver circuits must not share a non-isolated output group. -
HART-capable field servicing
Use the documented digital communication execution with a supported local or remote node path. -
Redundant combined I/O
A dual-redundant design needs the appropriate paired-module and terminal configuration in addition to this card.
Identify module-driven outputs and transmitter-driven inputs before connecting a calibrator.
Count receiver resistance and wiring, including the remote-node high-temperature restriction when applicable.
Trace receiver and output wiring continuity when open-circuit detection appears; verify delivered current.
Check the complete terminal assembly; the cable’s rating can limit the installation withstand.
The basic suffix must match the approved environment rather than borrowing H03 qualification.
Measure current at the output receiver and check actuator response independently of the input signal.
Alternative Names
Technical notes
Output interpretation: The command register and open-circuit status describe different aspects of the output path; use both during fault isolation.
Loop compliance: The receiver and cable must fit the allowed resistance window under the actual node temperature conditions.
Input conversion: The powered input’s protection drop must be included when evaluating a two-wire transmitter supply budget.
FAQ View All FAQ
-
Why is an eight-input AAI135 not equivalent to AAI835-H00 S1?The AAI835 splits its capacity between four inputs and four outputs. Reallocate measurement and command functions explicitly; an input-only card cannot replace the output half of this arrangement.
-
Can a correct input reading prove the output half of AAI835-H00 S1 is healthy?No. Measure delivered output current into the actual receiver load and check the output circuit indication. The acquisition and command paths have separate electrical functions and tolerances.
-
How should an open-output indication on AAI835-H00 S1 be investigated?Check receiver continuity, terminal engagement and series wiring under the approved isolation procedure. A plausible software command is not evidence that current reaches the load.
-
Can the input and output errors of AAI835-H00 S1 simply be assumed to cancel in a loopback test?No. For an illustrative worst-case electrical budget, ±16 µA input accuracy and ±48 µA output accuracy can add to ±64 µA, or 0.4% of a 16 mA span, before external test uncertainty and other applicable effects. Measure the two paths separately; their agreement alone cannot establish absolute loop accuracy.
-
Why might a low-resistance test load be unsuitable for AAI835-H00 S1 in a hot remote node?The documented output-load window changes at 60–70°C in a qualified remote node. Use a representative compliant load and verify the H00 execution and host environment are themselves appropriate.
-
How can source-versus-sink confusion be avoided when testing AAI835-H00 S1?Identify whether the test terminal is a module input or a module-driven output, and set the calibrator accordingly. Check the loop drawing before introducing another active current source.
-
What should be preserved when changing terminal adapters on AAI835-H00 S1?Retain the four-input/four-output channel map and the required isolation arrangement. Adapter mechanical fit is insufficient evidence of identical pin assignment or circuit function.
-
Does HART access establish closed-loop operation for AAI835-H00 S1?No. Digital instrument access is a separate check. Prove measurement scaling, delivered command current and the intended receiver response before accepting the control loop.
Supporting new and legacy automation
-
Please try to be as accurate as possible with your search.
-
We can quote you on 1000s of specialist parts, even if they are not listed on our website.
-
We can't find any results for “”.
Related cases and sourcing guidance
View all case studiesYou May Also Like
Product Browsing History
-
Whatsapp: +86 18030235313
Send us a message. -
sales13@apterpower.com
Complete our online form. -
+86 18030235313
Speak to our team in your native language.