Speak to a sourcing specialist
sales13@apterpower.com

AAI141-H03 S1

Non-Isolated Analog Input Module
Product image is representative; revision or series may vary. Contact us to request a specific version.

Product Describe:

This sixteen-input current module combines the legacy HART interface with the G3 and extended-temperature option. Its inputs remain non-isolated despite the environmental upgrade.
  • Manufacturer part number
    AAI141-H03 S1
  • Shipping
    Swift global dispatch
  • Condition
    New, original product
  • Shipping size (est.)
    3.3cm x 10.7cm x 13cm
  • Country of Origin
    Japan
Get a quick price for AAI141-H03 S1
E-mail *
Mobile
Company
Content *
Quantity *
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)
For more information on how your data is processed and stored by Apterpower please read our privacy policy

What happens after you enquire

  • 0

    Review your reference

    Send the full marking, quantity and label photos. We review the item and any version details that need clarification.
  • 1

    Confirm the offer

    Check the quoted reference, condition, included items and expected dispatch date before approving your order.
  • 2

    Arrange dispatch

    Confirm delivery details and receive the tracking number when it becomes available.
  • Match the complete marking

    Include AAI141-H03 S1 and every revision or approval marking visible on the item. Keep the exact reference on your enquiry and quotation.
  • Check the offered item before ordering

    Request available label and interface photos. Have your maintenance team compare the offered AAI141-H03 S1 reference with the installed equipment and applicable Yokogawa documentation.

Technical specifications for AAI141-H03 S1

  • Manufacturer:
    Yokogawa
  • Product Category:
    DCS Systems
  • Spare Part Number:
    AAI141-H03 S1
  • Weight:
    0.28 kg
  • Tariff Code:
    8537101190
  • Analog inputs:
    16 channels
  • Input signal:
    4–20 mA DC
  • Input current limit:
    27 mA
  • Input accuracy:
    ±16 µA
  • Data update:
    10 ms
  • Powered input resistance:
    400 Ω at 20 mA; 1000 Ω at 4 mA
  • Unpowered input resistance:
    ≥500 kΩ
  • Transmitter voltage at 20 mA:
    ≥14.8 V
  • Transmitter voltage at zero current:
    ≤26.4 V
  • 5 V supply consumption:
    310 mA maximum
  • 24 V supply consumption:
    450 mA maximum
  • Temperature drift:
    ±16 µA / 10°C
  • Channel isolation:
    Non-isolated
  • Input step response:
    100 ms
  • Temperature option:
    −20 to +70°C; compatible host/node required
  • Atmosphere option:
    ISA Standard G3

Information

Overview Downloads Applications / Compatibility Product Precautions
  • The H03 choice changes environmental execution while retaining the field-reference constraints of sixteen non-isolated current inputs.
Selected suffix: HART communication plus the G3/temperature option, not the H00 basic type.
Electrical grouping: Sixteen input circuits use the documented non-isolated architecture.
Host qualification: The extended ambient selection must be supported by the installed FIO node.
AAI141-H03 S1 is suited to a dense current-input group whose environmental requirement calls for H03. H00 offers the same nominal signal range but does not carry that selected option, so environmental interchangeability needs its own acceptance decision. Sixteen non-isolated inputs combine with the H03 G3 and qualified -20 to +70°C selection. The common-reference arrangement remains unchanged by the wider environmental suffix.

Temperature exposure does not change the module into an isolated input bank. A replacement plan must retain the existing field-reference arrangement and check whether an external isolation interface is required for particular instruments or hazardous-area circuits. At 20 mA the powered input burden is 400 Ω, compared with 1000 Ω at 4 mA. The specified input current limit is 27 mA; it is an allowable-input boundary rather than an instruction to use overrange current as a normal calibration point.

The sixteen channels can have different transmitter power arrangements. Documenting those choices before terminal removal prevents an internally powered two-wire configuration from being applied to an already powered four-wire device, especially when several similar loops are marshalled together. The rail requirements are 310 mA maximum at 5 V and 450 mA maximum at 24 V. Reserve those demands in the qualified node before adding transmitter circuits or neighboring modules; channel count alone is not a power-budget calculation.
Controller platform reference: CENTUM FIO analog I/O. Match node, termination and loop design.
System and supply context: AAI141-H03 S1 supplies a high-density legacy FIO current-input bank in a host qualified for the selected environmental option.

Integration boundary: Maintain the channel power-mode and field-reference plan while qualifying G3/temperature execution separately. The H03 module must be combined with a node and termination suitable for the same service environment. Preserve the ATA4S/ATA4D or ATK4A channel route and verify remote EB401 revision separately if HART is used.
Verify the environmental identity before accepting electrical test results as full replacement approval. Assess a bank-wide shift against the shared field common before recalibrating individual transmitters. Record the actual ambient and controlled input current so temperature influence is distinguishable from wiring-induced error.
Compare H03 with the ordered label

A physically fitting H00 card does not demonstrate the selected environmental execution.

Check local cabinet conditions

Verify the host/node and installed termination are suitable for the required ambient.

Audit common references

Preserve shared input references; the H03 environmental option does not add channel isolation.

Record mode settings before removal

Keep a channel-by-channel two-wire/four-wire record for all sixteen input positions.

Assess the loaded transmitter voltage

Check transmitter voltage at the highest required loop current, including the field-wire loss.

Recheck HART remotely

Where remote HART is required, verify EB401 Rev 2 or later and test it from the maintenance station.

Alternative Names

Yokogawa AAI141-H03 S1 Yokogawa AAI141 H03 S1

Technical notes

Ambient and drift: Assess allowed ambient and measurement drift separately; temperature qualification does not promise zero temperature-related measurement change.

Current-input selection: The legacy AAI141 input limit must not be replaced by the different AAI841 or newer-suffix table.

External interfaces: A barrier, terminal cable and node remain separately qualified elements of the finished loop.

FAQ View All FAQ

  • What evidence distinguishes AAI141-H03 S1 from a basic-type H00 spare?
    The full H03 marking establishes the selected G3 and temperature option. Retain that identity evidence alongside the node environmental qualification rather than relying only on a current-injection test.
  • Does AAI141-H03 S1 isolate a noisy transmitter from the other input circuits?
    Its architecture is non-isolated. Review the field reference and any required external isolation before connecting a circuit whose potential differs from the input-group design.
  • Why can a resistance measurement on an unpowered AAI141-H03 S1 mislead a live-loop assessment?
    Power-off input resistance is at least 500 kΩ, whereas the energized input has a current-dependent burden of 400–1000 Ω at the stated endpoints. Those are different circuit states. Assess source compliance with the module powered in the intended channel configuration, rather than substituting an unpowered resistance reading into a live-loop calculation.
  • How can sixteen channels on AAI141-H03 S1 be checked without masking a terminal swap?
    Apply a traceable test current to one identified terminal pair at a time and compare the intended configured channel. A group-wide plausible display can conceal crossed loop identities.
  • Does the 27 mA allowance extend the measurement-accuracy range of AAI141-H03 S1?
    It does not redefine the specified 4–20 mA signal band. Keep normal process scaling and overrange handling separate, and confirm the configured channel response before applying an overload test. An input-current allowance alone is not a guarantee of linear conversion or stated accuracy above the normal signal range.
  • Should AAI141-H03 S1 be accepted from an HART test alone?
    No. Digital access does not verify analog scaling or power-mode selection. Check analog indication, transmitter supply arrangement and HART communication as separate parts of the same loop.
  • What matters when replacing AAI141-H03 S1 in a redundant node?
    Retain the configured redundancy topology and the required environmental execution on the replacement path. Prove each path according to the approved plant procedure instead of assuming insertion establishes redundancy.
  • Why should AAI141-H03 S1 be checked at the midpoint as well as both process endpoints?
    Correct zero and full-scale readings can conceal an incorrect channel assignment or an error between the endpoints. Apply a known midpoint current after the input has settled, compare both the current interpretation and the configured engineering value, and keep that result separate from a successful HART connection.
SPEAK TO OUR TEAM
Let’s find the right solution for you.
Send us the part number, quantity and delivery destination. Our team will help confirm availability and lead time.
  • Whatsapp: +86 18030235313

    Send us a message.
  • sales13@apterpower.com

    Complete our online form.
  • +86 18030235313

    Speak to our team in your native language.