Match the complete marking
Include ALR121-S00 S1 and any series, revision or assembly markings. Keep the complete reference on your enquiry and quotation.
-
Check the offered item before ordering
Request available label, connector and mounting photos. Have your maintenance team compare the offered ALR121-S00 S1 with the installed equipment and applicable Yokogawa documentation.
Technical specifications for ALR121-S00 S1
-
Manufacturer:Yokogawa
-
Product Category:DCS Systems
-
Spare Part Number:ALR121-S00 S1
-
Weight:0.3 kg
-
Tariff Code:8537101190
-
Product series:CENTUM FIO
-
Reference design:ALR121
-
Serial interface (base design):RS-422 / RS-485
-
Communication ports:2
-
RS-422 topology:Point-to-point
-
RS-485 topology:Multipoint
-
Communication mode:Half-duplex
-
Synchronization:Start-stop
-
Base-design transmission rates:1200 to 115200 bps
-
Data format:ASCII / binary; 7 or 8 bits
-
Stop bits / parity:1 or 2; none / even / odd
-
Port connection:M4 screw terminals, 5 poles × 2
-
Base-design line distance:1200 m maximum total extended length
Information
- Yokogawa ALR121-S00 S1 exchanges subsystem data with the field control station through configured serial communication channels, linking devices such as programmable controllers to the control application.
Base interface: Two RS-422/RS-485 ports
Communication: Half-duplex, start-stop synchronization
System family: CENTUM FIO
Serial settings in the ALR121 hardware reference include 1200 to 115200 bps, ASCII or binary transmission, seven or eight data bits, one or two stop bits, and no, even or odd parity. Communication is half-duplex with start-stop synchronization. The response and data-format settings must agree at both ends so that a physically connected device can exchange meaningful data.
The two ports use M4 screw terminals with five poles per port and shielded three-pair wiring or the applicable AKB161/AKB162 cable. The base-design maximum transmission distance is 1200 m total extended length. Installation in an ESB or ER node or compact FIO control unit depends on the host model and software configuration; ER-node use also has firmware prerequisites. Match the complete ALR121-S00 S1 marking and installed revision before replacing a module.
-
Yokogawa ALR121-S00 S1 technical reference
Original manufacturer excerpt. Base-design specifications and configuration requirements; match the complete offered marking. PDF, 4 pages, 274.2 KB. -
Yokogawa ALR121-S00 S1 installation guide
Prepared by Apter Power. Product-specific preparation, interface checks, commissioning and functional acceptance. PDF, 5 pages, 26.7 KB.
Application scope: The following uses describe the supported base-design role. Confirm ALR121-S00 S1 against the installed host and configuration before replacement.
-
Programmable-controller data exchange
Connect a serial subsystem to the CENTUM control application using the appropriate Subsystem Communication Package and agreed data mapping. -
Point-to-point equipment link
Use the RS-422 interface for a direct serial connection. Align transmission speed, character format and communication timing with the connected device. -
Multipoint serial integration
Use the RS-485 interface for a configured multipoint network. Maintain the approved cable topology and the required endpoint settings. -
FIO subsystem maintenance
Restore a matched serial communication channel in the supported node or control unit. Check the host release, installed revision and saved communication configuration.
RS-422/RS-485 wiring is different from RS-232C. Do not use the ALR111 D-sub pinout for an ALR121 terminal connection.
Record speed, character length, parity and stop bits. A matching cable alone does not establish a working protocol configuration.
Use the approved shielded cable and terminal assignment. Preserve the five-terminal port identification and shield arrangement.
Confirm the node, FCS software and any ER-bus firmware prerequisites before installation.
Use approved isolation and ESD procedures. Record terminal connections and channel configuration before disconnecting the module.
Verify both ports where used, communication status and application data mapping before returning the subsystem to service.
Alternative Names
Technical notes
System relationship: Verify the FIO node or compact control unit and its host/software prerequisites; ER-node installation has additional firmware conditions.
Configuration boundary: The technical data describes the ALR121 base design. Match the complete ALR121-S00 S1 marking, style and installed configuration; do not transfer later suffix approvals or ratings automatically.
Technical reference: Yokogawa Subsystem Communication Module (for FIO), GS 33Q06Q46-31E, 9th edition.
FAQ View All FAQ
-
What serial interfaces does ALR121-S00 S1 use?The ALR121 base design has two RS-422/RS-485 ports. Match the installed port wiring and configured communication package.
-
How does the network topology differ on ALR121-S00 S1?RS-422 is point-to-point. RS-485 supports multipoint wiring; the selected interface must match the subsystem.
-
Which data formats are relevant to ALR121-S00 S1?The ALR121 reference supports ASCII or binary transmission, seven or eight data bits, and one or two stop bits. Both endpoints must use matching settings.
-
What parity settings can be used with ALR121-S00 S1?The base design supports no parity, even parity or odd parity. Use the setting required by the connected subsystem and application configuration.
-
Is communication through ALR121-S00 S1 full-duplex?No. The ALR121 communication mode is half-duplex with start-stop synchronization.
-
How are field cables connected to ALR121-S00 S1?Each ALR121 port uses five M4 screw terminals. The reference wiring is shielded three-pair cable or the appropriate AKB161/AKB162 cable.
-
What line length applies to the base design of ALR121-S00 S1?The ALR121 hardware reference gives 1200 m as the maximum total extended transmission distance. Apply the actual cable, topology and installation requirements.
-
What must be checked before placing ALR121-S00 S1 in an ER node?Verify the host FCS model, software release and EB401 firmware. ER-node installation has specific host-software conditions and requires EB401 revision R3 or later in the referenced configuration.
Supporting new and legacy automation
-
Please try to be as accurate as possible with your search.
-
We can quote you on 1000s of specialist parts, even if they are not listed on our website.
-
We can't find any results for “”.
Related cases and sourcing guidance
View all case studiesYou May Also Like
Product Browsing History
-
Whatsapp: +86 18030235313
Send us a message. -
sales13@apterpower.com
Complete our online form. -
+86 18030235313
Speak to our team in your native language.