Speak to a sourcing specialist
sales13@apterpower.com

AAI141-H00 S1

Non-Isolated Analog Input Module
Product image is representative; revision or series may vary. Contact us to request a specific version.

Product Describe:

A sixteen-channel FIO input module acquires standardized current signals without interchannel isolation. The H00 selection supplies the basic HART-capable execution for dense analog measurement.
  • Manufacturer part number
    AAI141-H00 S1
  • Shipping
    Swift global dispatch
  • Condition
    New, original product
  • Shipping size (est.)
    3.3cm x 10.7cm x 13cm
  • Country of Origin
    Japan
Get a quick price for AAI141-H00 S1
E-mail *
Mobile
Company
Content *
Quantity *
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)
For more information on how your data is processed and stored by Apterpower please read our privacy policy

What happens after you enquire

  • 0

    Review your reference

    Send the full marking, quantity and label photos. We review the item and any version details that need clarification.
  • 1

    Confirm the offer

    Check the quoted reference, condition, included items and expected dispatch date before approving your order.
  • 2

    Arrange dispatch

    Confirm delivery details and receive the tracking number when it becomes available.
  • Match the complete marking

    Include AAI141-H00 S1 and every revision or approval marking visible on the item. Keep the exact reference on your enquiry and quotation.
  • Check the offered item before ordering

    Request available label and interface photos. Have your maintenance team compare the offered AAI141-H00 S1 reference with the installed equipment and applicable Yokogawa documentation.

Technical specifications for AAI141-H00 S1

  • Manufacturer:
    Yokogawa
  • Product Category:
    DCS Systems
  • Spare Part Number:
    AAI141-H00 S1
  • Weight:
    0.28 kg
  • Tariff Code:
    8537101190
  • Analog inputs:
    16 channels
  • Input signal:
    4–20 mA DC
  • Input current limit:
    27 mA
  • Input accuracy:
    ±16 µA
  • Data update:
    10 ms
  • Powered input resistance:
    400 Ω at 20 mA; 1000 Ω at 4 mA
  • Unpowered input resistance:
    ≥500 kΩ
  • Transmitter voltage at 20 mA:
    ≥14.8 V
  • Transmitter voltage at zero current:
    ≤26.4 V
  • 5 V supply consumption:
    310 mA maximum
  • 24 V supply consumption:
    450 mA maximum
  • Temperature drift:
    ±16 µA / 10°C
  • Channel isolation:
    Non-isolated
  • Input step response:
    100 ms

Information

Overview Downloads Applications / Compatibility Product Precautions
  • Sixteen current measurements share a non-isolated module architecture, making field-reference compatibility central to selection.
Input density: Sixteen 4–20 mA inputs in one legacy FIO module.
Reference boundary: Non-isolated construction differs from the eight-channel AAI135 arrangement.
Acquisition timing: A 10 ms update and 100 ms input step response describe different parts of the signal path.
AAI141-H00 S1 prioritizes input density rather than channel separation. Replacing an isolated AAI135 with this module changes the electrical reference architecture as well as the channel count, so terminal compatibility cannot be decided from connector appearance. Each input has a two-wire/four-wire transmitter setting. The sixteen channels are non-isolated, so a high-density termination must preserve the intended shared references as well as the channel numbering.

Each current input supports the documented two-wire or four-wire transmitter selection. The powered input burden varies with current because its protection circuit adds a voltage drop; transmitter supply margin must be assessed under load rather than inferred from the open-circuit voltage. The input burden is 250 Ω plus a protective drop of up to 3 V divided by loop current: 400 Ω at 20 mA and 1000 Ω at 4 mA. This explains why checking a single nominal resistance is insufficient for transmitter compliance.

The legacy AAI141 specification permits a higher input current than the AAI841 input bank, but it remains a standardized measurement input rather than an unrestricted current sink. Node configuration, engineering range and installed wiring must be checked together when an overrange condition is evaluated. The available transmitter voltage is at least 14.8 V at 20 mA and at most 26.4 V at zero current. ATA4S-00, ATA4S-10, ATA4D-00 and ATA4D-10 are distinct simplex/dual and surge-option termination selections, not part of the bare module code.
Controller platform reference: CENTUM FIO analog I/O. Match node, termination and loop design.
System and supply context: AAI141-H00 S1 is an input-only current module for the compatible CENTUM FIO local/remote node architecture.

Integration boundary: Group sixteen signals only where their field electrical references are compatible with a non-isolated input module. A /K4A00 selection uses ATK4A-00, while /A4S00 and /A4D00 use the corresponding ATA4S and ATA4D pressure-clamp routes. Check the selected terminal mapping before changing a sixteen-loop bank.
Preserve the non-isolated field-reference design when replacing or extending this sixteen-input group. Keep current-injection equipment referenced to the approved bank common. Apply the channel powering setting before connecting a four-wire source so the source and module do not drive one another.
Review signal references

Check grounded transmitters and shared field connections before grouping the sixteen input loops.

Identify all sixteen positions

Trace terminal-to-channel assignment instead of assuming an eight-channel predecessor’s map.

Calculate full-current burden

Include the protection-circuit voltage drop when checking source compliance at full operating current.

Keep output work separate

This module has no current-output bank; do not transfer actuator wiring to an input terminal.

Use the appropriate safety interface

Use the approved isolation barrier for intrinsically safe loops; direct Zener connection is excluded.

Allow input settling

Allow the input step response to settle; the update cadence alone does not set acceptance dwell.

Alternative Names

Yokogawa AAI141-H00 S1 Yokogawa AAI141 H00 S1

Technical notes

Input burden model: The terminal-view resistance includes 250 Ω plus a protection voltage drop of up to 3 V divided by current.

Acquisition interpretation: A fast data refresh does not remove the analog step-response settling requirement.

Barrier compatibility: An external isolation barrier must be selected for intrinsically safe duties; the non-isolated module is not itself that barrier.

FAQ View All FAQ

  • Why is an isolated-input project not automatically compatible with AAI141-H00 S1?
    The module combines sixteen non-isolated inputs. Review field references and terminal grouping before replacing a design that relies on independently isolated input circuits.
  • How can source compliance be checked for AAI141-H00 S1 before installation?
    Calculate cable loss and the powered input’s current-dependent burden, then verify the source can maintain the upper test current. An open-circuit voltage check alone is insufficient.
  • Why should an AAI141-H00 S1 loop test dwell longer than one data update?
    The input step response is slower than its refresh interval. Hold each applied current long enough for a settled indication before attributing a transient error to calibration.
  • Does AAI141-H00 S1 accept actuator-output wiring from a combined I/O card?
    No. Identify every conductor by function: this card receives current signals and does not generate actuator commands. A combined I/O migration needs a separate output plan.
  • What distinguishes a wiring fault from an engineering-range error on AAI141-H00 S1?
    Apply known currents at the module-side input and compare raw/current interpretation with the configured process range. Correct current with incorrect process units points toward range configuration rather than field conversion.
  • How should four-wire transmitter loops be restored on AAI141-H00 S1?
    Confirm that the transmitter has its own supply, restore the matching channel setting and compare the loop drawing. Do not add module transmitter power merely because it is available.
  • What is missing if AAI141-H00 S1 is fitted but input redundancy is assumed?
    A single module does not establish the documented dual-redundant arrangement. Check the companion path, terminal configuration and project redundancy setup before claiming redundant acquisition.
  • Can a newer H50 designation be treated as identical to AAI141-H00 S1?
    The legacy H00 and later H50 identities are different order executions. Compare applicable hardware, node and revision documentation rather than transferring newer electrical limits into this S1 record.
SPEAK TO OUR TEAM
Let’s find the right solution for you.
Send us the part number, quantity and delivery destination. Our team will help confirm availability and lead time.
  • Whatsapp: +86 18030235313

    Send us a message.
  • sales13@apterpower.com

    Complete our online form.
  • +86 18030235313

    Speak to our team in your native language.