TC-308-02-2M5

Output Smart Slot Jumper Cable

Product Describe:

Output Smart Slot Jumper Cable

Connects adjacent output modules

to enable Smart Slot

(Hot-standby) redundancy

Ask our team:

Get a quick price for: TC-308-02-2M5
Quantity*
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)
For more information on how your data is processed and stored by Apterpower please read our privacy policy.

Technical specifications for TC-308-02-2M5

Technical specifications for TC-308-02-2M5

  • Manufacturer:
    ICS Triplex
  • Product Category:
    PLC Systems
  • Spare Part Number:
    TC-308-02-2M5
  • Estimated shipping dimensions:
    35x35x10cm
  • Weight:
    1.14 kg
  • Tariff Code:
    8537101190
  • Counliy of origin:
    USA
  • System Compatibility:
    Trusted TMR System
  • Revision Code:
    -02 (Current standard electrical configuration)
  • Isolation Strength:
    1500V DC (Galvanic isolation between channels and to ground)
  • Operating Temp:
    -5°C to +60°C
  • Safety Integrity Level:
    Certified for use in SIL 3 Safety Instrumented Systems
  • Hazardous Area:
    Approved for ATEX / IECEx Zone 2 installations

Information

Information

Overview Manuals Common Applications Product Precautions
TC-308-02-2M5 is a high-performance communication cable manufactured by ICS Triplex (now part of Rockwell Automation) specifically for Trusted TMR (Triple Modular Redundancy) systems.   
    • Excellent fault tolerance and redundancy capabilities
    • High security level of SIL 3
    • High-performance current and signal carrying capacity
The TC-308 System is a critical redundancy connection solution based on the ICS Triplex Trusted TMR architecture, utilizing high-specification specialized cables to establish electrical linkage between primary and standby modules. Supporting SIL 3 safety integrity, its core value lies in providing superior fault tolerance and online hot-repair capabilities through Smart Slot technology. It ensures seamless switching and automatic synchronization of faulty modules without system downtime, delivering a zero-outage safety guarantee for continuous operations in high-risk industries such as oil & gas, chemical, and power generation.

Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. 
 ICS Triplex TC-308-02-2M5 Output Smart Slot Jumper Cable Manuals, Datasheets, Drivers, Link Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description.
Oil & Gas Exploration
Applied in Emergency Shutdown Systems (ESD) to ensure immediate closure of wellhead valves in the event of a blowout.

Nuclear Power Plants
Utilized in Reactor Protection Systems to support online maintenance of critical safety logic modules.

Chemical Processing
Used for safety interlocking of high-pressure reactors to prevent runaway exothermic reactions caused by control failure.

Steel Manufacturing
Used for blast furnace cooling system monitoring to ensure redundant controllers remain online during high-temperature operations.

Pharmaceutical Industry
Used in environmental control for critical bioreactors to prevent batch loss due to control system failures.

Semiconductor Manufacturing
Applied in emergency shut-off for gas cabinets to protect cleanroom personnel from toxic gas exposure.
 Handle the cable with care during daily use. When plugging or unplugging, always grip the metal connector housing; never pull on the cable body itself to disconnect. Proper handling prevents damage to the delicate internal digital cores and solder joints, significantly extending the product's physical lifespan.

FAQS

  • What is the TC-308-02-2M5?
    The TC-308-02-2M5 is a dedicated Output Smart Slot Jumper Cable for the ICS Triplex Trusted system, with a length of 2.5 meters.
  • What is the core purpose of the TC-308-02-2M5?
    It is used to establish a physical connection between two output module slots (active and standby), supporting the Smart Slot feature for output module hot-standby redundancy.
  • How to correctly install the TC-308-02-2M5?
    It should be installed on the Field Termination Assembly (FTA) interfaces at the rear of the chassis, linking the main and standby modules, and ensure the locking screws on the connectors are tightened.
  • Which output modules are compatible with the TC-308-02-2M5?
    It is specifically designed for use with Output Modules of the Trusted system, such as the T8451 (Analog Output) or T8461 (Digital Output).
  • What is the difference between TC-308-02-2M5 and TC-306-02?
    The TC-308 series is for output, while the TC-306 series is for input. Their internal pin definitions and electrical characteristics are optimized specifically for output and input signals and are not interchangeable.
Trusted by 5,000+ plants worldwide | Backed by our vast inventory of top-tier control parts, modules and cards, fast shipments are dispatched to cover your urgent needs. ABOUT US >>
Disclaimer: We are not an authorized distributor or distributor of the product manufacturer of this website, The product may have older date codes or be an older series than that available direct from the factory or authorized dealers. Because our company is not an authorized distributor of this product, the Original Manufacturer`s warranty does not apply.While many DCS PLC products will have firmware already installed, Our company makes no representation as to whether a DSC PLC product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Our company also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from our company, its distributors, or any other source. Our company also makes no representations as to your right to install any such firmware on the product. Our company will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.

Product Browsing History

We’re Here When You Need Us

From product insights to customer service needs, our experienced service team will focus on getting you what you need quickly

Enquire

Complete our online form.

Call Us

Speak to one of our team.

Live Chat

Send us a message.