Product image is representative; revision or series may vary. Contact us to request a specific version.
Product Describe:
SOE & Process Historian
Software Package
PC Software package
for event log collection
Fully compatible with Windows-based
industrial workstations
and Engineering Stations
The T8013 is the SOE (Sequence of Events) and Process Historian software package for the Trusted safety system, specifically designed to run on standalone Engineering Stations.
Time resolution to 1 ms
Text based log file for import into other programs
User defined tag, description, state and display colours
The Trusted Sequence of Events (SOE) Collection program generates a time-stamped log of all faults, field trips, output actions etc. recorded by the 8000 Series System. The Trusted Process Historian (PH) program provides the user with the facility to log and record analogue variables. Both programs are supplied on a single disk, part number T8013. The programs enable the user to collect the appropriate data from the Controller via the Triple Modular Redundant (TMR) Communications Interface module. Communications between the Engineering Workstation and the System may be configured using the Serial or Ethernet ports.For standalone station configurations, the T8013 software suite offers high-capacity data processing, supporting up to 4,000 SOE digital points and 2,000 Process Historian analogue variables with a 1-millisecond resolution. The software ensures data integrity by automatically retrieving buffered sequences from the TMR Controller upon link restoration and allows for customized tags and exportable data in standard formats for third-party compatibility.
Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description.
ICS Triplex T8013 SOE & Process Historian Software Package Manuals, Datasheets, Drivers, Link
Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description.
Oil & Gas
Monitering emergency shutdown (ESD) status on offshore platforms and onshore wells, precisely tracing the second-by-second sequence of wellhead valve self-locking due to pressure anomalies.
Petroleum Refining
Used for emergency safety protection logic logging in fluid catalytic cracking (FCC) and hydrocracking units, tracing fault points of core heater interlock trips.
Pharmaceuticals
Providing tamper-proof records of critical interlock actions and temperature-pressure historical trends in high-pressure sterilization or hazardous reactor zones to meet compliance requirements.
Natural Gas
Installed on standalone stations across thousands of kilometers of pipeline compressor stations to record key historical parameters of unexpected gas turbine compressor unit shutdowns.
Gas-Fired Power
Applied in turbine Emergency Trip Systems (ETS) and Furnace Safeguard Supervisory Systems (FSSS) to analyze whether a sudden generator trip was caused by high vibration or boiler flameout.
When using the ICS Triplex T8013 software package, it is critical to ensure absolute compatibility with the controller's Toolset firmware and strictly avoid unauthorized modifications to the 32-character tag naming specifications. Meanwhile, due to the high-frequency data extraction on the standalone station, stable network bandwidth—ideally via redundant Ethernet—must be maintained, alongside scheduled automated database backups to prevent the loss of invaluable 1 ms resolution historical data caused by hard drive failures or communication buffer overflows.