IS200TRLYH1BHH

Relay Output Terminal Board
Product image is representative; revision or series may vary. Contact us to request a specific version.

Product Describe:

GE IS200TRLYH1BHH is a Mark VI relay terminal board with voted coil-drive feedback and a mixture of fused solenoid branches and dry-contact circuits.
  • Manufacturer part number
    IS200TRLYH1BHH
  • Shipping
    Swift global dispatch
  • Condition
    New, original product
  • Shipping size (est.)
    33cm x 17.5cm x 5.8cm
  • Country of Origin
    USA
Get a quick price for IS200TRLYH1BHH
E-mail *
Mobile
Company
Content *
Quantity *
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)
For more information on how your data is processed and stored by Apterpower please read our privacy policy

What happens after you enquire

  • 0

    Review your reference

    Send the full marking, quantity and label photos. We review the item and any version details that need clarification.

  • 1

    Confirm the offer

    Check the quoted reference, condition, included items and expected dispatch date before approving your order.

  • 2

    Arrange dispatch

    Confirm delivery details and receive the tracking number when it becomes available.

  • Match the complete marking

    Include IS200TRLYH1BHH and every revision or approval marking visible on the item. Keep the exact reference on your enquiry and quotation.

  • Check the offered item before ordering

    Request available label and interface photos. Have your maintenance team compare the offered IS200TRLYH1BHH reference with the installed equipment and applicable GE documentation.

Technical specifications for IS200TRLYH1BHH

  • Manufacturer:
    General Electric
  • Product Category:
    Gas Turbine Control
  • Spare Part Number:
    IS200TRLYH1BHH
  • Weight:
    1.16 kg
  • Relay channels:
    12, Form C
  • Contact current at 24 V DC:
    3 A
  • Contact current at 125 V DC:
    0.6 A
  • Contact current at 120/240 V AC:
    3 A
  • Fused output branches:
    6
  • Special unfused branch:
    1
  • Barrier terminals:
    48

Information

Overview Downloads Applications / Compatibility Product Precautions
  • The H1B relay arrangement matters when replacing a terminal board: H1C monitors contact voltage, while H1D uses a different six-channel arrangement. These are different diagnostic and wiring choices.
Coil-command supervision: The feedback checks relay drive rather than proving the voltage delivered to the field load.
Selective field powering: Fused solenoid branches and dry-contact duties must remain assigned to their original circuits.
Redundant control fit: Voted coil drive supports the documented simplex or TMR input arrangement.
The TRLYH1B implementation uses socketed, sealed mechanical Form C relays. MOV suppression belongs to this design; H1C adds a different contact-voltage feedback arrangement and R-C suppression. A spare selected solely by the TRLY name can therefore change the monitored fault boundary.

Field wiring terminates at barrier terminals. The six fused branches and the special unfused branch are separate power-distribution features; neither should be treated as a universal power feed for every relay. Keep the field supply, branch protection and dry-contact assignments tied to the turbine wiring record.

Coil-drive voting is compatible with simplex or TMR control inputs in the documented architecture. A successful command or healthy coil indication still requires a separate field-side proof: observe the intended load response and verify the de-energized contact state before releasing the circuit.
Controller platform reference: Mark VI relay I/O. Retain the documented GE configuration.
The technical reference covers Mark VI relay I/O. The independent field guide develops relay branches, coil feedback and field-load proof.
The technical reference retains selected original manufacturer pages. The separate installation guide supports field verification for IS200TRLYH1BHH.
Prepare GE IS200TRLYH1BHH for its configured installation using these product-specific checks.
Separate field power

Isolate each external relay-contact supply as well as the control-side supply.

Keep branch identities

Record fuse positions and dry-contact channels before moving wires.

Confirm the diagnostic variant

Compare H1B with the installed board; H1C and H1D have materially different feedback duties.

Check contact duty

Review voltage, load and existing suppression for the switched circuit.

Seat relay components

Inspect socket retention, terminals and the condition of suppression components.

Prove the field result

Test the receiving load and released state; a healthy coil command alone is insufficient.

Alternative Names

GE IS200TRLYH1BHH

Technical notes

Feedback boundary: H1B monitors voted coil drive; it does not provide the H1C contact-voltage feedback function.

Circuit allocation: A fuse-fed solenoid branch and a dry Form C contact must not be treated as the same field circuit.

Coil versus load proof: A voted coil-drive indication and an energized field load are different observations. Test the customer supply, protected branch and switched output separately.

FAQ View All FAQ

  • Can IS200TRLYH1BHH be replaced by a TRLYH1C without changing the diagnostic review?
    No automatic substitution is established. H1C adds isolated contact-voltage feedback and R-C suppression, whereas H1B supervises voted coil drive. Compare the configured fault logic and circuit drawings before approving a change.
  • Does a healthy coil indication on IS200TRLYH1BHH prove that a solenoid has energized?
    It proves only the monitored drive condition. A fuse, field supply, contact or return fault can still prevent load operation; check field voltage and the intended actuator response through an approved test.
  • Why must the fused branches of IS200TRLYH1BHH be recorded separately from dry contacts?
    The branches distribute external power, while a dry contact switches the circuit provided by the installation. Preserve their individual supply and protection assignments when transferring wiring.
  • What changes if IS200TRLYH1BHH is installed in a simplex system instead of TMR?
    The control-input arrangement changes. Restore the actual simplex cable and configured I/O assignment; the presence of connectors for redundant control does not create a TMR installation.
  • Is the H1D relay arrangement equivalent to IS200TRLYH1BHH for a twelve-channel circuit?
    No. The H1D comparison uses six Form A relays and a different solenoid-integrity diagnostic. Compare contact form, channel allocation and monitoring requirements before considering that design.
  • How should the AC and DC contact ratings of IS200TRLYH1BHH be applied?
    Select the rating for the actual switched voltage and duty. Do not apply the 24 V DC current limit to a 125 V DC circuit; also retain the circuit-specific fuse and suppression design.
  • Why can only one solenoid remain off while the other outputs of IS200TRLYH1BHH respond?
    Start with that channel’s assigned branch feed, fuse, relay contacts and field return. Compare coil-drive feedback with measured contact-side voltage; common I/O communication can remain healthy while a single protected branch is open.
  • How should a dry-contact duty be tested after fitting IS200TRLYH1BHH?
    Use the installed contact assignment and an approved isolated test circuit to compare the commanded and released contact states. A dry contact does not supply its own field power; verify the actual receiving circuit separately.
SPEAK TO OUR TEAM
Let’s find the right solution for you.
Send us the part number, quantity and delivery destination. Our team will help confirm availability and lead time.
  • Whatsapp: +86 18030235313

    Send us a message.
  • sales13@apterpower.com

    Complete our online form.
  • +86 18030235313

    Speak to our team in your native language.