Include DS200TCDAG1BFD DS215TCDAG1BZZ01A and every revision or approval marking visible on the item. Keep the exact reference on your enquiry and quotation. -
Check the offered item before ordering
Request available label and interface photos. Have your maintenance team compare the offered DS200TCDAG1BFD DS215TCDAG1BZZ01A reference with the installed equipment and applicable GE documentation.
Technical specifications for DS200TCDAG1BFD DS215TCDAG1BZZ01A
-
Manufacturer:General Electric
-
Product Category:Gas Turbine Control
-
Spare Part Number:DS200TCDAG1BFD DS215TCDAG1BZZ01A
-
Weight:0.38 kg
-
Nominal contact interrogation:125 V DC
-
Conditional alternative interrogation:24–125 V DC
-
Contact current at 125 V DC:4 mA
-
Terminal-board isolation group:8 inputs
Information
Overview
Downloads
Applications / Compatibility
Product Precautions
- Contact interrogation originates in the power-distribution arrangement, while each contact input is optically isolated on TCDA; lost interrogation can therefore resemble a failed input card.
Optically isolated acquisition: Field contact state is separated from the receiving digital circuit.
Source-aware diagnosis: Interrogation power loss is distinguished from input interpretation.
Grouped field isolation: Terminal-board grouping affects how a ground-fault investigation is planned.
Source-aware diagnosis: Interrogation power loss is distinguished from input interpretation.
Grouped field isolation: Terminal-board grouping affects how a ground-fault investigation is planned.
TCDA reads contact inputs within the Mark V digital I/O core arrangement. The offered identity preserves both DS200TCDAG1BFD and DS215TCDAG1BZZ01A. The base/assembly markings do not by themselves reveal the installed firmware or authorize copying another board’s EPROM set.
The normal interrogation source is the internal 125 V DC distribution bus with fuse isolation and current limiting. Other documented voltages from 24 to 125 V DC may require an external source. Each contact input is optically isolated on TCDA, so field-loop power and card interpretation are distinct checks when several inputs disappear together.
DTBA and DTBB terminal boards provide interrogation-isolation jumpers in groups of eight contacts. The manufacturer restricts that isolation work to a stopped turbine. Retain the actual core, terminal assignment and source arrangement, and prove contact state through to the intended logic after the complete accepted board identity is restored.
The normal interrogation source is the internal 125 V DC distribution bus with fuse isolation and current limiting. Other documented voltages from 24 to 125 V DC may require an external source. Each contact input is optically isolated on TCDA, so field-loop power and card interpretation are distinct checks when several inputs disappear together.
DTBA and DTBB terminal boards provide interrogation-isolation jumpers in groups of eight contacts. The manufacturer restricts that isolation work to a stopped turbine. Retain the actual core, terminal assignment and source arrangement, and prove contact state through to the intended logic after the complete accepted board identity is restored.
Controller platform reference: Mark V digital I/O core. Match the installed configuration.
For DS200TCDAG1BFD DS215TCDAG1BZZ01A, the Apter Power technical reference summarizes verified manufacturer data. The field guide develops interrogation-power and contact-to-logic fault separation.
DS200TCDAG1BFD DS215TCDAG1BZZ01A Technical Reference
Apter Power technical reference with manufacturer-based values and exact application boundaries. PDF · 1 pages · 91.0 KB.DS200TCDAG1BFD DS215TCDAG1BZZ01A Installation & Commissioning Guide
Interrogation-Power and Contact-to-Logic Fault Separation. Resolve common field-loop power loss before changing a contact-processing assembly. PDF · 2 pages · 93.5 KB.
The technical reference is an Apter Power summary of the documented product data. The separate installation guide supports field verification for DS200TCDAG1BFD DS215TCDAG1BZZ01A.
System and supply context: For the Mark V contact-input/digital-I/O arrangement with its actual CD/QD core assignment.
Application scope: Interrogation source, terminal-board grouping and logic mapping must be retained together; relay contact ratings belong to their own hardware.
Application scope: Interrogation source, terminal-board grouping and logic mapping must be retained together; relay contact ratings belong to their own hardware.
Contact-state restoration
Compare the field contact and intended logic point after restoring the identified TCDA path.Common interrogation fault
Check the source and fuse/current-limited path when several inputs change together.Stopped-turbine ground diagnosis
Use the documented grouped terminal isolation only under the approved stopped condition.Assembly and firmware retention
Record both offered markings and the accepted application/EPROM identity before replacement.
Prepare GE DS200TCDAG1BFD DS215TCDAG1BZZ01A for its configured installation using these product-specific checks.
Keep both identities
Retain the complete DS200 and DS215 order pair.
Check actual interrogation voltage
Do not apply a default bus voltage to an externally powered installation.
Separate optical isolation from power
An isolated input still needs the correct interrogation circuit.
Stop before grouped isolation
Do not disconnect interrogation groups on a running turbine.
Preserve application devices
Record approved firmware and programmable-device identity before exchange.
Verify logic mapping
Prove the intended contact indication without forcing unrelated control actions.
Alternative Names
GE DS200TCDAG1BFD DS215TCDAG1BZZ01A
Technical notes
Source duty: The documented normal bus and a conditional external interrogation source are different arrangements.
Terminal duty: Grouped interrogation jumpers are on DTBA/DTBB, not a generic adjustment to make on the processor board.
Assembly duty: Combined order markings do not establish delivered EPROM contents or relay contact ratings.
FAQ View All FAQ
-
Why can several lost contact indications be an interrogation fault rather than a failure of DS200TCDAG1BFD DS215TCDAG1BZZ01A?A common source path can affect multiple field contacts. Compare interrogation power and grouping with individual contact states before condemning the input-processing board.
-
Does optical isolation on DS200TCDAG1BFD DS215TCDAG1BZZ01A remove the need to check field-loop power?No. Isolation separates circuits; it does not supply the required interrogation voltage. Verify the actual source and return for the affected contacts.
-
Can an external interrogation source be added automatically when fitting DS200TCDAG1BFD DS215TCDAG1BZZ01A?Use the approved installed circuit. The documented alternative voltage range does not authorize changing the source or reference without an engineering decision.
-
Where should grouped contact isolation associated with DS200TCDAG1BFD DS215TCDAG1BZZ01A be traced?Identify the DTBA/DTBB terminal-board jumpers and their actual groups. Perform the manufacturer’s isolation work only with the turbine stopped under the approved procedure.
-
Why can an open contact appear as logic 1 through DS200TCDAG1BFD DS215TCDAG1BZZ01A?The TCDA inversion mask changes a hardware 0 into logic 1 when set to 1, supporting the documented fail-safe trip/alarm convention. Compare the assigned point type and inversion setting before reversing field wiring merely to obtain the expected screen indication.
-
Can relay contact ratings be assigned to DS200TCDAG1BFD DS215TCDAG1BZZ01A from a core-wide table?The core includes separate terminal and relay hardware. Use the rating for the actual switching component rather than treating the aggregate core as one card.
-
What should be checked if a contact changes locally but not through DS200TCDAG1BFD DS215TCDAG1BZZ01A?Trace interrogation, terminal grouping, cable/core identity and the intended logic assignment. Compare a controlled contact transition at each relevant boundary.
-
Why might a contact transition reach logic through DS200TCDAG1BFD DS215TCDAG1BZZ01A but produce no change record?TCDA change detection is separately mask-controlled. A change-detect mask of 0 disables that point's change reporting even though its state can still be used by logic. Check the configured reporting mask and approved event path before replacing an electrically responsive input board.
Manufacturers
Supporting new and legacy automation
Whether you're maintaining existing equipment or sourcing parts for current systems, we provide fast, dependable supply you can rely on.
-
Please try to be as accurate as possible with your search.
-
We can quote you on 1000s of specialist parts, even if they are not listed on our website.
-
We can't find any results for “”.
PRODUCTS IN SEARCH PAGE ()
50+ account managers available now
Related reading
Related cases and sourcing guidance
View all case studies-
GE Mark & ICS Triplex Spares: Supporting Production RecoveryRead case > -
Invensys 3806E Sourcing: Five Spares Delivered to the CustomerRead case > -
24 Siemens Spare Parts Delivered to an Australian Waste Management FacilityRead case > -
Bently Nevada Cables and Proximitors Delivered to DubaiRead case >
Manufacturers
You May Also Like
Explore related automation components available through Apter Power.
Manufacturers
Product Browsing History
Revisit the products you recently viewed on Apter Power.
-
DS200TCDAG1BFD DS215TCDAG1BZZ01AProduct Details -
IS200TSVCH2AJEProduct Details -
IS200EPSMG1ADCProduct Details -
DS200TBPAG1ACCProduct Details -
IS200TRLYH1BHHProduct Details -
IS200VRTDH1DACProduct Details -
IS200EPSMG1AECProduct Details -
IS200TVIBH2BCCProduct Details -
IS200EDCFG1AEDProduct Details -
IS200TSVOH1BDCProduct Details
SPEAK TO OUR TEAM
Let’s find the right solution for you.
Send us the part number, quantity and delivery destination. Our team will help confirm availability and lead time.
-
Whatsapp: +86 18030235313
Send us a message. -
sales13@apterpower.com
Complete our online form. -
+86 18030235313
Speak to our team in your native language.