Match the complete marking
Include DS200TBPAG1ACC and every revision or approval marking visible on the item. Keep the exact reference on your enquiry and quotation. -
Check the offered item before ordering
Request available label and interface photos. Have your maintenance team compare the offered DS200TBPAG1ACC reference with the installed equipment and applicable GE documentation.
Technical specifications for DS200TBPAG1ACC
-
Manufacturer:General Electric
-
Product Category:Gas Turbine Control
-
Spare Part Number:DS200TBPAG1ACC
-
Weight:0.4 kg
-
Documented milliamp input paths:4
-
Input signal range:4–20 mA
-
Diagrammed input shunt:100 Ω
Information
Overview
Downloads
Applications / Compatibility
Product Precautions
- TBPA terminates the field current circuit ahead of the TCPA/DCPA processing path; a correct field current must be distinguished from the receiving interpretation.
Termination-level diagnosis: Field wiring and downstream processing can be examined as separate fault locations.
Defined current-loop interface: The input path includes a shunt relationship that matters when tracing a loop.
Traceable PLU connections: Terminal and interboard identities stay associated with the installed signal assignment.
Defined current-loop interface: The input path includes a shunt relationship that matters when tracing a loop.
Traceable PLU connections: Terminal and interboard identities stay associated with the installed signal assignment.
The Mark V PLU diagram places TBPA between the field milliamp circuit and the TCPA/DCPA receiving path. It is a termination interface in that documented arrangement. The larger PLU diagram also contains proximity and output functions; their aggregate capacities must not be assigned to this single terminal board.
The milliamp diagram shows four 4–20 mA input paths and a 100-ohm input shunt. Trace the actual signal pair, excitation arrangement and interboard connection before interpreting a failed indication as a processor fault. A loop-current reading at the field end and the signal reaching the receiving path are separate evidence points.
Retain the G1ACC marking and the unit-specific terminal assignment when selecting the spare. The family signal diagram does not establish an undocumented ACC-to-other-revision exchange. After the wiring is restored, use the approved controlled input check to compare field stimulus and receiving indication at more than one point.
The milliamp diagram shows four 4–20 mA input paths and a 100-ohm input shunt. Trace the actual signal pair, excitation arrangement and interboard connection before interpreting a failed indication as a processor fault. A loop-current reading at the field end and the signal reaching the receiving path are separate evidence points.
Retain the G1ACC marking and the unit-specific terminal assignment when selecting the spare. The family signal diagram does not establish an undocumented ACC-to-other-revision exchange. After the wiring is restored, use the approved controlled input check to compare field stimulus and receiving indication at more than one point.
Controller platform reference: Mark V PLU signal termination. Match the installed configuration.
For DS200TBPAG1ACC, the Apter Power technical reference summarizes verified manufacturer data. The field guide develops plu loop, shunt and receiving-channel verification.
DS200TBPAG1ACC Technical Reference
Apter Power technical reference with manufacturer-based values and exact application boundaries. PDF · 1 pages · 91.2 KB.DS200TBPAG1ACC Installation & Commissioning Guide
PLU Loop, Shunt and Receiving-Channel Verification. Follow a controlled current change from the field pair through termination to its intended receiving indication. PDF · 2 pages · 93.5 KB.
The technical reference is an Apter Power summary of the documented product data. The separate installation guide supports field verification for DS200TBPAG1ACC.
System and supply context: Use in the documented Mark V PLU current-input termination arrangement.
Application scope: The field-loop path and TCPA/DCPA interpretation must both be checked; connector fit alone cannot prove the correct signal assignment.
Application scope: The field-loop path and TCPA/DCPA interpretation must both be checked; connector fit alone cannot prove the correct signal assignment.
PLU current-loop restoration
Trace each field signal pair to its retained terminal and receiving assignment.Shunt-path investigation
Separate current continuity from the signal presented through the documented termination path.Interboard connection recovery
Preserve cable identification between TBPA and the receiving electronics.Controlled input acceptance
Compare applied current with the intended receiving indication under the approved test plan.
Prepare GE DS200TBPAG1ACC for its configured installation using these product-specific checks.
Retain the G1ACC marking
Do not infer a revision exchange from the TBPA acronym.
Identify the loop source
Record excitation and return before disconnecting field wiring.
Protect terminal assignments
Label the actual signal pair and receiving channel.
Keep processing separate
Do not treat the termination board as the whole PLU logic system.
Inspect the shunt path
Use the approved isolated test method before drawing a fault conclusion.
Prove several input points
Compare controlled stimulus and receiving interpretation before release.
Alternative Names
GE DS200TBPAG1ACC
DS200TBPAG1ACC
Technical notes
Capacity boundary: PLU-wide proximity and output counts are not standalone TBPA ratings.
Measurement boundary: Loop continuity does not establish correct receiving scale or channel assignment.
Revision boundary: The documented signal path does not establish ACC revision interchangeability.
FAQ View All FAQ
-
How can a field-loop fault be separated from the receiving path when diagnosing DS200TBPAG1ACC?Compare the identified field current path with the TBPA termination and downstream interboard connection under the approved test procedure. Retain both stimulus and receiving evidence.
-
Does a correct current reading prove DS200TBPAG1ACC is assigned to the correct signal?No. Compare the terminal pair and receiving channel with the unit-specific record, then prove the intended indication with a controlled input change.
-
Can total PLU proximity counts be used as capacities of DS200TBPAG1ACC?No. The diagram includes multiple assemblies and functions. Apply the TBPA milliamp-path data only to its documented termination role.
-
Why should excitation and return be recorded before disconnecting DS200TBPAG1ACC?They establish how the actual field loop is powered and referenced. Reconnecting a signal pair without that relationship can leave an incorrect loop even when continuity is present.
-
What should be investigated if DS200TBPAG1ACC receives current but the displayed value is wrong?Compare the termination/shunt path, interboard connection, receiving channel and retained scale. A valid current at one point does not prove the entire interpretation chain.
-
Is the TCPA/DCPA function included merely by ordering DS200TBPAG1ACC?These are separately identified processing assemblies in the signal path. Confirm the actual spare scope rather than treating the terminal board as a complete PLU.
-
Can a nearby TBPA revision be substituted automatically for DS200TBPAG1ACC?Retain the complete group and revision and obtain the approved compatibility decision. The common family diagram alone does not establish that exchange.
-
What closes a signal restoration using DS200TBPAG1ACC?Record field-loop identity, terminal/cable assignment, controlled input points and the matching receiving indications, with any discrepancy resolved before release.
Manufacturers
Supporting new and legacy automation
Whether you're maintaining existing equipment or sourcing parts for current systems, we provide fast, dependable supply you can rely on.
-
Please try to be as accurate as possible with your search.
-
We can quote you on 1000s of specialist parts, even if they are not listed on our website.
-
We can't find any results for “”.
PRODUCTS IN SEARCH PAGE ()
50+ account managers available now
Related reading
Related cases and sourcing guidance
View all case studies
Manufacturers
You May Also Like
Explore related automation components available through Apter Power.
Manufacturers
Product Browsing History
Revisit the products you recently viewed on Apter Power.
-
DS200TBPAG1ACCProduct Details -
IS200TRLYH1BHHProduct Details -
IS200VRTDH1DACProduct Details -
IS200EPSMG1AECProduct Details -
IS200TVIBH2BCCProduct Details -
IS200EDCFG1AEDProduct Details -
IS200TSVOH1BDCProduct Details -
IS200EISBH1AABProduct Details -
IS215VPROH1BEProduct Details -
IS200ECTBG2ADEProduct Details
SPEAK TO OUR TEAM
Let’s find the right solution for you.
Send us the part number, quantity and delivery destination. Our team will help confirm availability and lead time.
-
Whatsapp: +86 18030235313
Send us a message. -
sales13@apterpower.com
Complete our online form. -
+86 18030235313
Speak to our team in your native language.