Product Describe:

A Mark VIe backup-protection terminal board that conditions speed and PT signals for PPRO I/O packs and connects them to the selected trip-relay board.
  • Manufacturer part number
    IS200TPROH1CBB
  • Shipping
    Swift global dispatch
  • Condition
    New, original product
  • Shipping size (est.)
    33x17.7x5cm
  • Country of Origin
    USA
Get a quick price for IS200TPROH1CBB
E-mail *
Mobile
Company
Content *
Quantity *
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)
For more information on how your data is processed and stored by Apterpower please read our privacy policy

What happens after you enquire

  • 0

    Review your reference

    Send the full marking, quantity and label photos. We review the item and any version details that need clarification.
  • 1

    Confirm the offer

    Check the quoted reference, condition, included items and expected dispatch date before approving your order.
  • 2

    Arrange dispatch

    Confirm delivery details and receive the tracking number when it becomes available.
  • Match the complete marking

    Include IS200TPROH1CBB and every hardware or assembly-revision marking visible on the item. Keep the exact reference on your enquiry and quotation.
  • Check the offered item before ordering

    Request available label and interface photos. Have your maintenance team compare the offered IS200TPROH1CBB reference with the installed equipment and applicable General Electric documentation.

Technical specifications for IS200TPROH1CBB

  • Manufacturer:
    General Electric
  • Product Category:
    Gas Turbine Control
  • Spare Part Number:
    IS200TPROH1CBB
  • Weight:
    0.9 kg
  • Tariff Code:
    8537101190
  • Field terminals:
    2 removable 24-point barrier blocks
  • PPRO positions:
    3: JR1 / JS1 / JT1
  • Trip-board cable interfaces:
    3 x DC-37: JX1 / JY1 / JZ1
  • Speed input paths:
    9; 3 per R/S/T section
  • Magnetic pickup frequency:
    2-20000 Hz, documented matched system
  • Pulse-rate accuracy:
    0.05% of reading, documented matched system
  • Sensitivity, 0-2 kHz:
    27 mV peak-to-peak required
  • Sensitivity, 2-6 kHz:
    50 mV peak-to-peak required
  • Sensitivity, 6-10 kHz:
    100 mV peak-to-peak required
  • Sensitivity, 10-15 kHz:
    160 mV peak-to-peak required
  • Sensitivity, above 15 kHz:
    250 mV peak-to-peak required
  • PT input burden:
    <3 VA per input
  • PT synchronization range:
    75-130 Vrms
  • PT isolation barrier:
    1500 Vrms
  • Customer sensor outputs:
    3 x 24 VDC, 25 mA maximum each; not voted
  • Operating temperature:
    -30 to 65 deg C, documented board design

Information

Overview Downloads Applications / Compatibility Product Precautions
  • GE IS200TPROH1CBB combines field-signal termination with a three-pack backup-protection interface; H1C uses removable barrier terminals rather than the H2C Euro-style terminals.
Protection role: TPRO conditions backup-protection inputs; the selected relay board provides the trip interface.
Pack positions: R, S and T PPRO packs occupy JR1, JS1 and JT1.
Platform distinction: TPROH#C belongs to Mark VIe and is not supported by Mark VI control.
IS200TPROH1CBB retains the H1C removable barrier-terminal arrangement. It supports the documented simplex or TMR PPRO architecture, with three pack positions and three DC-37 trip-board cable interfaces. The H2C Euro-terminal version and Mark VI TPRO arrangements have different installation boundaries and must not be substituted by name alone.

The board conditions nine speed-input paths and includes bus/generator PT input functions. Magnetic pickup sensitivity depends on frequency, so a nominal pulse frequency is insufficient for an input test. The PT function also has an application enable condition; a disabled live value is not automatically a failed transformer input.

Customer P24 outputs are sourced from the ORed pack power path and are not voted outputs. Removing one pack therefore does not establish that the field sensor supply is dead. The connected trip board must be selected for its actual emergency-stop voltage, relay arrangement and output requirements; TPRO alone does not establish the complete trip-system rating.
Controller platform reference: Mark VIe TPRO / PPRO backup protection. Match terminal form, pack and trip board.
Preserve turbine-protection independence and verify all pack-derived field-power sources.
Maintain independent trip authority

Use the approved turbine-protection outage and test procedure before disturbing the backup path.

Confirm H1C terminals

Retain the removable barrier blocks and point map; do not infer H2C Euro-terminal equivalence.

Set test amplitude by frequency

Use the applicable sensitivity band when simulating magnetic speed inputs.

Check PT function enablement

Compare the K25A_Enab configuration before diagnosing a missing bus/generator live value.

Verify sensor-power isolation

Account for ORed pack supplies and measure P24 before handling active-sensor conductors.

Match the trip-board interface

Verify relay-board type, E-stop voltage and cable allocation; keep 240 VAC and DC circuits from unintended cross-connection.

Alternative Names

GE IS200TPROH1CBB General Electric IS200TPROH1CBB

Technical notes

Pack power versus board load: The certificate pack supply figure belongs to the combined I/O pack system and is not a standalone TPRO consumption rating.

P24 continuity: The sensor output can remain powered by the other packs when one pack is off; isolation must be verified electrically.

Sensitivity acceptance: A low-amplitude high-frequency pulse can fail detection even when its frequency is within range; evaluate amplitude and frequency together.

FAQ View All FAQ

  • Does a TTL speed input on IS200TPROH1CBB use the same signal landing as a passive pickup?
    The documented TTL table uses TB3 for TTL High and a corresponding even-numbered TB2 return. For the first R-path example, TTL High is TB3 pin 1 and its return is TB2 terminal 32. Reconcile sensor type, path and the approved wiring table together; copying a passive-pickup landing does not establish the TTL connection.
  • Can unused P24 capacity from other IS200TPROH1CBB outputs automatically support a 40 mA sensor?
    Each of the three customer 24 V outputs is specified for a maximum 25 mA. The presence of three outputs does not document permission to pool them or parallel connections for a larger load. Compare each sensor demand with its assigned output and use an approved power arrangement when that demand exceeds the individual limit.
  • What PT cable condition should be retained when verifying IS200TPROH1CBB from a remote test point?
    The documented PT input allows up to 1000 ft of 18 AWG wiring. That condition does not establish an arbitrary cable installation as equivalent. Record the installed conductor and length, compare voltage at the board under its input burden, and retain the bus/generator allocation; a correct voltage at the remote source alone is incomplete evidence.
  • Can equal bus and generator PT test voltages conceal swapped inputs on IS200TPROH1CBB?
    Yes. The board has two separate bus/generator PT input functions, so applying the same test value to both does not distinguish their allocation. Under the authorized test plan, identify each source and compare its corresponding live channel separately, with the required application enable condition established before interpreting a missing value.
  • Does working PPRO Ethernet communication prove the trip-board cable path of IS200TPROH1CBB?
    The pack network, direct pack-to-terminal connection and DC-37 relay-board connection are different interfaces. A healthy network service does not prove the correct JX1/JY1/JZ1 cable or relay-board identity. Reconcile the hardware ID and cable allocation, then verify the required end-to-end trip function under the approved protection test.
  • Do three pack mounting positions make every IS200TPROH1CBB arrangement a valid TMR system?
    Mounting capacity alone does not define the installed protection architecture. The compatibility table distinguishes trip boards: TREG and TREL entries are TMR, while the listed TRES entries support simplex as well as TMR. Confirm the selected pack count, trip-board execution and controller configuration together before approving an arrangement.
  • Can the IS200TPROH1CBB PCB be mounted directly on metal when the carrier is changed?
    The documented assembly includes a plastic insulator between TPRO and its sheet-metal carrier or panel-mount assembly. Preserve that insulating component and the intended mounting method during a mechanical change. A matching hole pattern does not establish the same electrical or mechanical assembly condition.
  • Does the 1500 Vrms PT isolation figure permit a 1500 V signal at an IS200TPROH1CBB input?
    No. The isolation barrier and the 75-130 Vrms synchronization input envelope describe different conditions. Keep the actual signal within its operating envelope and follow the approved test method; a barrier withstand figure is not a measurement range or permission for a connected-system high-voltage test.