Match the complete marking
Include 2711-T10C8X and its visible series on the enquiry. Compare the DH+ port, AC input and panel fit with the installed terminal before replacing it.
-
Check the offered item before ordering
Request clear nameplate, front-panel and connector photographs of the offered 2711-T10C8X. Have the maintenance team compare them with the installed equipment and applicable Rockwell documentation.
Technical specifications for 2711-T10C8X
-
Manufacturer:Allen-Bradley
-
Product Category:HMI Panels
-
Spare Part Number:2711-T10C8X
-
Weight:2.78 kg
-
Tariff Code:8537101190
-
Operator terminal family:PanelView 1000 Color
-
Operator input:Touch screen
-
Display technology:Color active-matrix TFT with CCF backlight
-
Active display area:211 x 158 mm
-
Pixel resolution:640 x 480
-
Touch-cell matrix:384 cells, 24 columns x 16 rows
-
Touch-cell footprint:26 x 30 pixels
-
Controller interface:DH+
-
Separate peripheral interface:RS-232 printer and application transfer
-
Engineering software:PanelBuilder32
-
Application flash:1008 KB nonvolatile plus 310 KB runtime for 1000 color family
-
Input supply:85–264 V AC, 47–63 Hz; no L1 DC suffix
-
Maximum AC consumption:55 VA maximum for AC 1000 color family
-
Operating ambient:0 to +55 °C
-
Storage ambient:−25 to +70 °C
-
Relative humidity:5–95%, non-condensing, over operating range
-
Front protection:NEMA Type 12/13 and 4X indoors; IP54/IP65, when correctly installed
-
Status indicators:Green COMM and red fault indicators
-
Application storage:ATA memory card supported
-
Real-time clock:Battery-backed, serviceable module
-
Field backlight:Replaceable; 50,000 h half-life at 25 °C for 1000 color family
Information
- The installed PanelBuilder32 project defines the operator screens, touch targets and controller data map. Preserve it before changing this terminal.
Network acceptance: Prove the DH+ connection using the configured controller address and real data transactions.
Touch acceptance: Test every used touch target and alarm acknowledgement in an approved machine state.
The selected controller communication path is DH+, with a distinct RS-232 port for printer or application-transfer duties. The DH+ station must have a unique node address and matching network speed. Restoring the screen file alone does not prove controller data exchange; preserve the network configuration and verify a live read/write path after installation.
The unsuffixed catalog selection uses AC input. For a replacement, compare the exact 2711-T10C8X nameplate and series, panel cutout, supply wiring, installed application and peripheral cable. Record the as-found alarm and touch behavior, then commission each used function against the approved machine sequence.
-
Allen-Bradley 2711-T10C8X technical reference
Apter Power reference with verified manufacturer data and exact-model applicability. -
Allen-Bradley 2711-T10C8X engineering guide
Apter Power installation, configuration, diagnostic and acceptance guidance.
Platform applications: The uses below depend on the installed controller configuration and approved system design.
-
Operator process view
Present controller values, status and alarm objects assigned by the saved PanelBuilder32 project. -
DH+ controller station
Exchange project-mapped values through the installed DH+ network and its configured node or rack. -
Touch command entry
Send project-defined touch-screen actions only after validating the controller permissives. -
Maintenance recommissioning
Restore the approved project and test display, controller transactions and any used RS-232 peripheral.
Retain the installed application, firmware identity and controller addressing before removing the terminal.
Verify AC input and protective earth using the approved electrical procedure before energizing.
Check DH+ cable, termination, interface settings and controller status against the installed drawing.
Compare the terminal bezel, panel cutout and depth with the actual enclosure before mounting.
Verify every used touch cell, navigation path, alarm and acknowledgement after project restoration.
Treat the RS-232 printer/transfer lead as distinct from the controller network.
Alternative Names
Technical notes
Interface boundary: The selected controller port is DH+; the RS-232 peripheral port has a separate role.
Project dependency: The screen and touch behavior depend on the installed PanelBuilder32 application.
Marking and condition: Retain the nameplate X suffix. For PanelView 1000, Rockwell nomenclature uses X for a reconditioned-product designation; the offered physical condition is recorded separately from that catalog designation.
Technical reference: Rockwell Automation 2711-UM014G-EN-P and 2711-TD007A-EN-P; 2711-CT013A-EN-E for the PanelView 1000 X convention.
FAQ View All FAQ
-
How should the application on 2711-T10C8X be preserved before a terminal change?Archive the PanelBuilder32 project and its revision, record firmware and network settings, and capture representative screens and alarms. Restore the approved file before proving machine operation.
-
Why can 2711-T10C8X show its project yet fail to update live controller values?The display can run independently of a healthy DH+ connection. Check controller state, cable, network addressing and the project data map before replacing the terminal.
-
What should be checked if a touch target on 2711-T10C8X selects the wrong function?Compare the active screen and programmed touch-cell assignment with the loaded project. Inspect touch calibration and controller permissives; test in an approved machine state.
-
How can the RS-232 port on 2711-T10C8X be distinguished from its controller link?Trace the cable to the printer or transfer computer and review port settings. The controller data path is DH+; an RS-232 peripheral connection does not replace its network configuration.
-
What evidence is needed before reusing a stored application on 2711-T10C8X?Match terminal family, firmware, project revision, communications selection and controller tag or address map. Compare a test screen and an approved live transaction before release.
-
How should a dark but otherwise communicating 2711-T10C8X be investigated?Check display brightness and backlight condition while observing COMM and fault indications. Confirm input power under load and follow the applicable backlight maintenance procedure for the actual series.
-
How should a 677 or 678 network message on 2711-T10C8X be investigated?On DH+, 677 indicates unstable communication and 678 indicates a duplicate node. Check network wiring, baud settings and all node addresses, then retest the controller link.
-
What constitutes an acceptance test for 2711-T10C8X after replacement?Prove representative displayed values, all used touch actions, alarms and acknowledgements, network recovery and any installed printer path. Retain the exact marking, project and as-left test result.
Supporting new and legacy automation
-
Please try to be as accurate as possible with your search.
-
We can quote you on 1000s of specialist parts, even if they are not listed on our website.
-
We can't find any results for “”.
Related cases and sourcing guidance
View all case studiesYou May Also Like
Product Browsing History
-
Whatsapp: +86 18030235313
Send us a message. -
sales13@apterpower.com
Complete our online form. -
+86 18030235313
Speak to our team in your native language.