Match the complete marking
Include 2094-BSP2 and every revision or approval marking visible on the item. Keep the exact reference on your enquiry and quotation. -
Check the offered item before ordering
Request available label and interface photos. Have your maintenance team compare the offered 2094-BSP2 reference with the installed equipment and applicable Allen-Bradley documentation.
Technical specifications for 2094-BSP2
-
Manufacturer:Allen-Bradley
-
Product Category:Servo Drives
-
Spare Part Number:2094-BSP2
-
Weight:2.6 kg
-
Tariff Code:8537101190
-
Module function:Regenerative-energy shunt module
-
Internal shunt capacity:200 W
-
Compatible drive classes:230 V and 460 V Kinetix 6000 systems
-
Mounting system:Bulletin 2094 power rail
-
Rail allocation:One shunt module per power rail
-
External resistor connector:RC connector
-
Thermal switch connector:TS connector
-
Internal resistor selection:Enabled with the default RC jumper
-
Mounting screw torque:2.26 N m (20 lb in)
-
Rail placement:Right of IAM and AM modules; left of slot fillers
Information
- 2094-BSP2 adds a 200 W internal shunting path to Kinetix 6000-class power rails when regenerative energy exceeds the integrated axis-module capacity.
Rail integration: Installs on a Bulletin 2094 power rail with a single shunt module allowed per rail.
Wiring boundary: RC and TS connections govern external resistor and thermal-switch use.
The factory RC jumper enables the internal resistor. External-resistor use changes the RC and TS wiring, so the installed schematic and thermal protection path must be checked before energization.
Acceptance should confirm the complete rail order, one-module-per-rail rule, connector jumpers, mounting torque and absence of bus or thermal faults during a controlled deceleration test.
-
Allen-Bradley 2094-BSP2 official technical excerpt
Selected manufacturer pages covering the applicable family, technical data and exact order-code fields. -
Allen-Bradley 2094-BSP2 engineering guide
Apter Power installation, configuration, diagnostic and acceptance guidance.
Platform applications: The uses below depend on the installed controller configuration and approved system design.
-
Regenerative deceleration
Dissipate returned energy where the installed motion profile exceeds the IAM or AM internal shunt duty. -
Multi-axis power rail
Provide a shared shunting point on a Bulletin 2094 rail after the installed axis modules. -
External resistor interface
Use the RC and TS connectors only with the documented external-resistor and thermal-switch circuit. -
Installed-base service
Preserve rail width, slot order, jumpers and drive-voltage class when replacing the module.
Verify the drive's stored-energy wait and measure the bus before touching rail or shunt connections.
Do not install a second 2094-BSP2 on the same Bulletin 2094 power rail.
Install after the IAM and axis modules and before slot-filler modules.
Match the jumper or external-resistor wiring to the approved drive schematic.
Confirm the external thermal-switch circuit whenever an external resistor is used.
Monitor the bus and shunt status under an approved deceleration test before release.
Alternative Names
Technical notes
Rail relationship: Use only within the documented Bulletin 2094 rail order and voltage class.
Shunt selection: The installed duty cycle and regenerated energy determine whether the internal or approved external resistor path is used.
Commissioning focus: Record jumper state, mounting torque, bus response and thermal status during the approved stop test.
FAQ View All FAQ
-
Where is 2094-BSP2 positioned on a Bulletin 2094 power rail?Install it to the right of the IAM and axis modules and to the left of any slot fillers, following the published rail-order diagram.
-
How many 2094-BSP2 modules may be installed on one power rail?The installation instructions allow one shunt module per Bulletin 2094 power rail.
-
What does the default RC jumper do on 2094-BSP2?It enables the module's internal 200 W resistor; remove or reconfigure it only for the documented external-resistor circuit.
-
When is the TS connector required for 2094-BSP2?Use the TS path when the approved external shunt resistor requires thermal-switch supervision.
-
Which drive-voltage classes accept 2094-BSP2?The module is documented for both 230 V and 460 V Kinetix 6000 drive systems.
-
What mounting torque applies to 2094-BSP2?Tighten the mounting screw to 2.26 N m (20 lb in) after the module is fully seated on the rail connector.
-
What should be recorded before replacing 2094-BSP2?Record rail order, drive-voltage class, RC/TS wiring, jumper state, connected resistor identity and the bus-fault history.
-
How should 2094-BSP2 be functionally accepted?Use an approved controlled deceleration and confirm stable bus behavior, shunt status and thermal protection without faults.
Supporting new and legacy automation
-
Please try to be as accurate as possible with your search.
-
We can quote you on 1000s of specialist parts, even if they are not listed on our website.
-
We can't find any results for “”.
Related cases and sourcing guidance
View all case studiesYou May Also Like
Product Browsing History
-
Whatsapp: +86 18030235313
Send us a message. -
sales13@apterpower.com
Complete our online form. -
+86 18030235313
Speak to our team in your native language.