Match the complete marking
Include 2198-P141 and every revision or approval marking visible on the item. Keep the exact reference on your enquiry and quotation. -
Check the offered item before ordering
Request available label and interface photos. Have your maintenance team compare the offered 2198-P141 reference with the installed equipment and applicable Allen-Bradley documentation.
Technical specifications for 2198-P141
-
Manufacturer:Allen-Bradley
-
Product Category:Servo Drives
-
Spare Part Number:2198-P141
-
Weight:4.1 kg
-
Tariff Code:8537101190
-
Power-supply role:Kinetix 5700 DC-bus supply
-
Input class:480 V AC, three-phase
-
Input current class:47 A
-
Continuous DC-bus current:46.9 A rms
-
Continuous output at 480 V:31 kW
-
Continuous output at 240 V:15.5 kW
-
Module width:85 mm
-
Bus architecture:Common DC bus for Kinetix 5700 inverter modules
-
Lifecycle status:Active product
Information
- 2198-P141 is the 47 A Kinetix 5700 DC-bus supply that converts the three-phase line input into the common bus used by connected inverter modules.
Rated class: 47 A input class with 46.9 A rms continuous DC-bus output.
Mechanical format: 85 mm wide module for the Kinetix 5700 modular drive line.
Line protection, grounding, contactor strategy, bus sharing, connected inverter demand and regenerative-energy management must be evaluated as one drive system rather than as independent module ratings.
Commissioning should verify phase sequence, protective devices, DC-bus polarity and voltage, connected-axis inventory and the absence of bus, input-power or precharge faults.
-
Allen-Bradley 2198-P141 technical reference
Selected manufacturer pages covering the applicable family, technical data and exact order-code fields. -
Allen-Bradley 2198-P141 engineering guide
Apter Power installation, configuration, diagnostic and acceptance guidance.
Platform applications: The uses below depend on the installed controller configuration and approved system design.
-
Common-bus source
Supply the shared DC bus for a documented Kinetix 5700 inverter group. -
High-axis-count machine
Coordinate the 31 kW at 480 V continuous class with simultaneous axis demand and duty cycle. -
Panel replacement
Retain the 85 mm position, line protection, grounding and bus-bar arrangement from the approved drawing. -
Drive-system expansion
Recalculate input, bus and regenerative capacity before adding inverter modules or changing motion profiles.
Apply the documented discharge wait and prove both mains and DC-bus absence before service.
Verify the approved 480 V-class source, phase sequence and protective device selection.
Inspect bus bars and connectors before energizing the common DC bus.
Sum inverter continuous and peak demand against the approved power-system design.
Verify the installed braking or regenerative solution for the machine duty cycle.
Capture input voltage, bus voltage, current loading and diagnostic state under the approved test.
Alternative Names
Technical notes
Power relationship: The published kW value changes with the applied input-voltage class.
Bus relationship: Connected inverter demand and regenerative energy are evaluated at the common DC bus.
Acceptance focus: Verify input protection, grounding, bus polarity, precharge and connected-axis diagnostics.
FAQ View All FAQ
-
What role does 2198-P141 perform in a Kinetix 5700 system?It converts the three-phase mains input into the common DC bus used by compatible Kinetix 5700 inverter modules.
-
What continuous DC-bus current is published for 2198-P141?The published continuous DC output is 46.9 A rms for the documented supply configuration.
-
How does line voltage affect 2198-P141 output power?The published continuous output is 31 kW at 480 V and 15.5 kW at 240 V, so apply the value for the installed line class.
-
How wide is 2198-P141 in the modular drive lineup?The module width is 85 mm; preserve the approved panel spacing and bus arrangement.
-
What must be checked before replacing 2198-P141?Record the line source, protection, grounding, bus bars, inverter inventory, braking arrangement and active fault history.
-
Can additional inverters be added behind 2198-P141 without review?No. Recalculate continuous and peak bus demand, mains current and regenerative duty before changing the axis group.
-
What polarity checks apply to 2198-P141?Inspect the common-bus connectors and bus-bar polarity against the system drawing before any energization.
-
How should 2198-P141 be accepted after installation?Verify phase sequence, input voltage, bus precharge and steady voltage, connected-axis recognition and absence of supply faults.
Supporting new and legacy automation
-
Please try to be as accurate as possible with your search.
-
We can quote you on 1000s of specialist parts, even if they are not listed on our website.
-
We can't find any results for “”.
Related cases and sourcing guidance
View all case studiesYou May Also Like
Product Browsing History
-
Whatsapp: +86 18030235313
Send us a message. -
sales13@apterpower.com
Complete our online form. -
+86 18030235313
Speak to our team in your native language.