Product Describe:

ABB 07KP64 GJR5240600R0101 is a Procontic T200 RCOM communication processor with master/slave operation, a modem interface and a separate commissioning console path.
  • Manufacturer part number
    07KP64 GJR5240600R0101
  • Shipping
    Swift global dispatch
  • Condition
    New, original product
  • Shipping size (est.)
    7.1cm x 13cm x 25cm
  • Country of Origin
    Sweden
Get a quick price for 07KP64 GJR5240600R0101
E-mail *
Mobile
Company
Content *
Quantity *
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)
For more information on how your data is processed and stored by Apterpower please read our privacy policy

What happens after you enquire

  • 0

    Review your reference

    Send the full marking, quantity and label photos. We review the item and any version details that need clarification.

  • 1

    Confirm the offer

    Check the quoted reference, condition, included items and expected dispatch date before approving your order.

  • 2

    Arrange dispatch

    Confirm delivery details and receive the tracking number when it becomes available.

  • Match the complete marking

    Include 07KP64 GJR5240600R0101 and every revision or approval marking visible on the item. Keep the exact reference on your enquiry and quotation.

  • Check the offered item before ordering

    Request available label and interface photos. Have your maintenance team compare the offered 07KP64 GJR5240600R0101 reference with the installed equipment and applicable ABB documentation.

Technical specifications for 07KP64 GJR5240600R0101

  • Manufacturer:
    ABB
  • Product Category:
    PLC Systems
  • Spare Part Number:
    07KP64 GJR5240600R0101
  • Weight:
    0.8 kg
  • RCOM slaves, network maximum:
    254
  • RCOM slaves with MasterPiece 200:
    8
  • Serial interface connector:
    9 pole
  • Serial interface electrical standard:
    RS-232-C / EIA RS-232-C
  • Serial interfaces:
    2 x RS-232

Information

Overview Downloads Applications / Compatibility Product Precautions
  • The RCOM processor must be distinguished from the adjacent MODBUS and PDnet communication products. A similar serial connector does not establish the same protocol or application program.
Remote communication role: RCOM links the retained T200 and supported supervisory-system arrangement.
Separate console access: Commissioning observation is distinct from the modem communication path.
Application-aware exchange: Protocol functions include startup, data transfer, event polling and clock synchronization.
The R101 communication processor has two RS-232 interfaces and uses RCOM for its remote communication duty. Keep console access separate from the modem/application link: successful commissioning access does not demonstrate remote process-data exchange.

The RCOM modem interface uses RS-232-C, while the additional console interface supports commissioning tasks such as observing the communication sequence and setting telephone numbers. Keep the modem and console destinations separate. The interface-cable table identifies 07 SK 90 for the console-to-terminal relationship and 07 SK 92 for the RCOM-to-standard-modem relationship.

The supported RCOM functions include cold and warm start, reset, clock synchronization, data reading/writing and event polling. Preserve the RCOM application and remote-node behavior when exchanging the processor. The programming computer specifications in the software documentation must not be quoted as onboard processor memory or electrical data.
Controller platform reference: Procontic T200 RCOM. Retain the documented ABB configuration.
The technical reference covers Procontic T200 RCOM. The independent field guide develops rcom roles, modem routing and application exchange.
The technical reference retains selected original manufacturer pages. The separate installation guide supports field verification for 07KP64 GJR5240600R0101.
Prepare ABB 07KP64 GJR5240600R0101 for its configured installation using these product-specific checks.
Retain the RCOM application

Save the existing program and remote-node assignments before exchange.

Separate console and modem

Tag both cable destinations and their different functions.

Check supervisory limits

Use the limit for the actual MasterPiece or general RCOM arrangement.

Do not transfer PC specifications

Programming-computer RAM and DOS requirements are not module parameters.

Review startup behavior

Compare cold/warm-start expectations with the retained remote application.

Test real data exchange

Verify the intended read/write or event-polling duties across the remote link.

Alternative Names

ABB 07KP64 GJR5240600R0101

Technical notes

Protocol boundary: RS-232-C describes the electrical interface; it does not imply MODBUS or a different communication application.

Network boundary: The general RCOM slave limit and the MasterPiece 200 limit are different conditions.

Processor versus workstation: The R101 processor has two RS-232 interfaces. The 907 KP 64 programming-PC requirements describe a different piece of equipment and must not be used as processor memory ratings.

FAQ View All FAQ

  • Does an RS-232 connector make 07KP64 GJR5240600R0101 interchangeable with a MODBUS processor?
    No. The electrical interface does not establish the communication protocol or application program. Confirm the retained RCOM duty and remote-node behavior before considering a change.
  • Why is the MasterPiece 200 connection important when sizing a network around 07KP64 GJR5240600R0101?
    The documented slave-count limit for that supervisory arrangement is lower than the general RCOM maximum. Use the actual master/system context when validating the remote-node list.
  • Which cable relationship distinguishes the console from the modem on 07KP64 GJR5240600R0101?
    The manufacturer table identifies 07 SK 90 for the console/terminal relationship and 07 SK 92 for the RCOM/standard-modem path. Match the connection duty instead of choosing by plug appearance.
  • If the console of 07KP64 GJR5240600R0101 works, has the remote communication link passed?
    No. The console and modem paths are separate. Prove the intended remote data exchange and node behavior in addition to successful commissioning access.
  • Why should a console-cable adaptor be checked when commissioning access to 07KP64 GJR5240600R0101 fails?
    The 07 SK 90 console arrangement includes terminal/adaptor and active/passive connection choices. Compare the fitted cable and terminal setup with that connection scheme before treating a blank console as failure of the separate RCOM modem path.
  • What must be preserved when changing 07KP64 GJR5240600R0101 in a station that uses clock synchronization?
    Retain the RCOM program, station role and the way the application uses its software clock/time. Verify the remote synchronization behavior after restoration.
  • Why can current data arrive through 07KP64 GJR5240600R0101 while alarms from a remote station remain absent?
    The RCOM software supports event polling in addition to ordinary data exchange. Compare the intended node’s event-poll behavior and application handling separately from a successful read/write transaction.
  • What must be checked when 07KP64 GJR5240600R0101 communicates after a warm start but not a cold start?
    Compare the retained RCOM program, station role and intended startup/reset sequence. The supported cold- and warm-start functions are different application events; record remote-node response rather than treating either result as a universal modem failure.
SPEAK TO OUR TEAM