Speak to a sourcing specialist
sales13@apterpower.com

190501-07-00-04

Low-Frequency Casing Velocity Transducer
Product image is representative; revision or series may vary. Contact us to request a specific version.

Product Describe:

Bently Nevada 190501-07-00-04 is a low-frequency Velomitor CT with a 3/8-24 plate stud and two-pin MIL-C-5015 interface.
  • Manufacturer part number
    190501-07-00-04
  • Shipping
    Swift global dispatch
  • Condition
    New, original product
  • Shipping size (est.)
    10.2cm x 4cm x 3.4cm
  • Country of Origin
    USA
Get a quick price for 190501-07-00-04
E-mail *
Mobile
Company
Content *
Quantity *
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)
For more information on how your data is processed and stored by Apterpower please read our privacy policy

What happens after you enquire

  • 0

    Review your reference

    Send the full marking, quantity and label photos. We review the item and any version details that need clarification.

  • 1

    Confirm the offer

    Check the quoted reference, condition, included items and expected dispatch date before approving your order.

  • 2

    Arrange dispatch

    Confirm delivery details and receive the tracking number when it becomes available.

  • Match the complete marking

    Include 190501-07-00-04 and every revision or approval marking visible on the item. Keep the exact reference on your enquiry and quotation.

  • Check the offered item before ordering

    Request available label and interface photos. Have your maintenance team compare the offered 190501-07-00-04 reference with the installed equipment and applicable Bently Nevada documentation.

Technical specifications for 190501-07-00-04

  • Manufacturer:
    Bently Nevada
  • Product Category:
    Machinery Monitoring Systems
  • Spare Part Number:
    190501-07-00-04
  • Weight:
    0.35 kg
  • Velocity sensitivity:
    3.94 mV/(mm/s) / 100 mV/(in/s), +/-5%
  • Frequency response:
    1.5 Hz to 1 kHz (+/-3 dB)
  • Tighter response band:
    3 to 900 Hz (+/-1 dB)
  • Peak velocity range:
    63.5 mm/s
  • Amplitude linearity:
    +/-2% to 63.5 mm/s peak
  • Transverse response:
    <5%
  • Mounted resonance:
    >=9 kHz (stud mount, excluding quick disconnect)
  • Output bias:
    10.1 +/-1 V DC (A relative to B)
  • Dynamic output impedance:
    <400 ohm typical
  • Operating temperature:
    -40 to +85 deg C
  • Shock limit:
    5000 g peak
  • Connector contacts:
    2
  • Mounting interface:
    3/8-24 to 3/8-24 plate stud
  • Mounting torque:
    4.5 +/-0.6 N m
  • Maximum cable length:
    305 m (02173006 cable)

Information

Overview Downloads Applications / Compatibility Product Precautions
  • Low-frequency cooling-tower velocity measurement. Evaluate low-frequency running-speed vibration transmitted to a rigid housing.
Low-speed fan response: The CT design captures vibration associated with slow cooling-tower machinery.
Integrated velocity signal: The piezoelectric sensing path supplies casing velocity for the receiving monitor.
Isolated electronics: Internal circuitry is isolated from the case to support the documented wiring arrangement.
The Velomitor CT measures casing velocity on cooling-tower and air-cooled heat-exchanger fans, including low running speeds. The selected plate stud establishes the machine interface; the connection option is the two-pin MIL-C-5015 interface.

Its useful low-frequency response differs from the standard 330500 Velomitor. The broader velocity range or higher-temperature rating of another sensor must not be transferred to this CT execution.

A casing measurement represents rotor condition only where vibration is transmitted to the mounting point. Choose a rigid bearing-housing location and compare fan, motor and gearbox components within the documented response and amplitude limits.
Controller platform reference: 190501 Velomitor CT. Use the specified system configuration.
Use the technical reference for manufacturer values and the field guide for low-frequency cooling-tower velocity measurement.
The technical reference retains selected original manufacturer pages. The separate installation guide supports field verification for 190501-07-00-04.
System and supply context: The CT velocity family addresses slow cooling-tower and heat-exchanger fan machinery.

Application scope: Choose a casing point that transmits rotor vibration and retains the low-frequency components of interest at the receiving input.
Prepare Bently Nevada 190501-07-00-04 for its configured installation using these product-specific checks.
Select a transmitting location

Retain the approved bearing or casing point for the slow fan.

Inspect the plate stud

Verify both thread interfaces and rigid seating before attaching the sensor.

Trace two-pin polarity

Identify A and B against the receiving monitor diagram.

Establish the low-frequency baseline

Compare fan operating speed and representative casing response after installation.

Low fan component is absent

Check mounting-point transmissibility and input high-pass filtering before condemning the sensor.

Clipping during high-frequency activity

Review the CT velocity limit and acceleration components above the useful band.

Alternative Names

190501 07 00 04 190501/07/00/04

Technical notes

CT response: The low-frequency velocity band addresses slow fan machinery and differs from the standard Velomitor band.

Machine transmission: A casing point is useful only when it transmits relevant rotor vibration to the mounted transducer.

Cable qualification: The stated cable maximum and recommended high-frequency/amplitude condition are distinct limits; evaluate the actual route capacitance.

FAQ View All FAQ

  • What should be reviewed before using 190501-07-00-04 on a fan turning below 90 rpm?
    The manufacturer describes this CT design for fan assemblies operating at or above 90 rpm. For a slower machine, review the intended vibration frequencies, input filtering and sensor suitability rather than extending the published application downward from the product name alone.
  • How can high-frequency activity reduce usable velocity measurement with 190501-07-00-04?
    The specified CT velocity range can be significantly reduced by acceleration components above 1 kHz exceeding the stated high-frequency condition. Review the complete vibration spectrum and operating-range curves when clipping or unexpected amplitude occurs; a low fundamental fan speed does not exclude high-frequency acceleration.
  • Why do the 305-metre maximum and the condition-based cable recommendation differ for 190501-07-00-04?
    They describe different performance conditions. The recommendation considers vibration amplitude, frequency and cable capacitance, while the maximum uses the specified interconnect cable. Review the actual route capacitance and signal duty; do not treat the largest length as an unconditional design allowance.
  • Can the minimum mounted resonance be assumed after adding quick-disconnect hardware to 190501-07-00-04?
    The stated minimum resonance is for the stud-mounted condition and explicitly excludes quick disconnect. The ordered plate-stud interface and a proposed quick-disconnect assembly therefore need separate mechanical review. Do not carry the stud-mounted resonance claim across an added mounting stack without applicable evidence.
  • What should be investigated when 190501-07-00-04 reports little vibration at a visibly moving fan assembly?
    Check whether the chosen mounting point transmits the relevant rotor vibration into the casing measurement. The manufacturer identifies that mechanical transmission as essential. Compare the mounting location and receiving-channel filtering before concluding that either the transducer or the machine is healthy.
  • How should phase polarity be checked when connecting 190501-07-00-04 to an existing channel?
    Use the documented base-to-top motion and Pin A relative to Pin B convention, then compare it with the receiving input wiring and any channel inversion. Correct amplitude alone cannot establish matching phase polarity. Preserve the chosen mechanical orientation in the acceptance record.
  • Why can a very small low-frequency indication from 190501-07-00-04 require a noise-floor review?
    The CT datasheet includes a frequency-dependent low-frequency noise-floor curve. Compare the observed level with the applicable sensor and channel conditions before interpreting a small indication as machine motion. A valid sensitivity number does not imply unlimited resolution near the low-frequency end.
  • Does a normal bias reading certify the mechanical installation of 190501-07-00-04?
    Bias is an electrical condition referenced between the specified pins; it does not establish mounting-point transmission, plate-stud seating or the useful frequency response of the installed assembly. Confirm those mechanical conditions and compare a controlled operating response before releasing the fan-monitoring function.
SPEAK TO OUR TEAM
Let’s find the right solution for you.
Send us the part number, quantity and delivery destination. Our team will help confirm availability and lead time.
  • Whatsapp: +86 18030235313

    Send us a message.
  • sales13@apterpower.com