Technical specifications for YPK113A
-
Manufacturer:ABB
-
Product Category:General Automation
-
Spare Part Number:YPK113A
-
Weight:0.14 kg
-
Selectable bit rate, maximum:19200 bit/s
-
RS-232 connector pins:9
-
Current-loop interface:20 mA
-
Mounting screws:3 x M3
Information
- YPK113A is the UART option, distinct from the YPK112A AF100 board and YPK117A Modbus board. The ACV700 arrangement connects board X1 to APC X5; the selected protocol and actual external interface must match the installed application.
Controller-mounted communication: The board plugs into the APC rather than operating as a standalone network controller.
Protocol-specific integration: The remote device and application mapping determine the useful exchange, beyond serial activity alone.
X2 is the nine-pole D connector for RS-232. X3 is the screw-terminal connection for a 20 mA current loop. Bit rate is selectable up to 19200 bit/s. The board requires no separate external supply except for the current-loop connection; that exception must be resolved against the actual installation drawing.
The ACV700 description lists SAMI, Allen-Bradley DF1 and Siemens S3964/S3964R. The DCV700 catalogue separately uses Allen-Bradley DH context wording. Select the installed platform’s protocol and configuration, then prove commands, statuses and data interpretation with the remote device; the names do not establish a universal interchangeable cable.
YPK113A Original Technical Reference Excerpt
Selected original manufacturer pages for the applicable interfaces and technical data. PDF · 2 pages · 43.5 KB.YPK113A Installation & Commissioning Guide
APC UART Interface and Protocol Restoration. Resolve controller seating, external serial circuit and protocol/data interpretation as three independent decisions before accepting the restored UART link. PDF · 2 pages · 92.2 KB.
Application scope: Identify the actual protocol and remote device before selecting X2 RS-232 or X3 current loop. AF100 and the neighboring Modbus board are different communication options.
APC-mounted UART link
Restore the X1-to-X5 controller connection and the board retention. Keep the remote application and data mapping with this hardware record.X2 RS-232 installation
Use the nine-pole D interface for its documented RS-232 duty. Preserve the installed pin assignment and serial settings rather than assuming a universal cable.X3 current-loop installation
Review the 20 mA screw-terminal circuit and its external supply requirement. Do not transfer the RS-232 connection or power assumption to this path.Protocol and remote-data fit
Match SAMI, DF1 or S3964/S3964R to the ACV700 application. Resolve any DCV700 DH context against the actual system before accepting a protocol change.
Use the approved power isolation before disturbing X1/X5 or the retaining screws.
Compare the actual RS-232 cable assignment; a D connector alone does not define pinout.
Resolve the current-loop power exception against the installed circuit before energization.
Use the accepted rate up to the supported ceiling, with matching remote settings.
Do not apply YPK117A Modbus behavior or an AF100 wiring assumption to the UART board.
Verify the intended commands and statuses before releasing the communication duty.
Alternative Names
Technical notes
Protocol scope: The ACV700 description names DF1; the DCV700 catalogue names a DH context. These labels are not asserted to be equivalent.
Power exception: The no-separate-supply statement excludes the current-loop connection; review X3 power from the actual circuit drawing.
Adjacent-board boundary: YPK117A Modbus slave counts and current-loop channel behavior do not specify YPK113A.
FAQ View All FAQ
-
Why can X2 on YPK113A not be used as a direct replacement for an X3 circuit?X2 is RS-232 on a nine-pole D connector, while X3 is a 20 mA current-loop screw-terminal interface. Reconcile signaling, wiring and current-loop supply from the installed drawing before changing the connection.
-
What power detail must be reviewed when YPK113A uses the current-loop interface?The manufacturer’s no-external-supply statement explicitly excludes the current loop. Identify its actual external supply and circuit arrangement before energizing X3; do not assume the RS-232 power relationship applies.
-
How should a bit-rate mismatch on YPK113A be investigated?Compare the selected rate and other retained serial settings at the APC/application and remote device. The board permits rates up to 19200 bit/s, but the maximum is not a required setting; confirm valid application exchanges at the installed common setting.
-
Does replacing YPK113A with YPK117A preserve the existing protocol?No such equivalence follows. YPK113A lists SAMI, DF1 and S3964/S3964R in the ACV700 description, whereas YPK117A is the separate Modbus board. Review the entire remote-system/application relationship before migration.
-
What controller-side fit should be checked if YPK113A has been removed during APC work?In the documented ACV700 arrangement X1 mates with APC X5 and the board is fixed by three M3 screws. Inspect connector seating and retention under the approved isolated procedure, then test the external data relationship separately.
-
Why can serial traffic from YPK113A coexist with incorrect remote commands?Electrical traffic does not establish protocol or application data mapping. Compare the selected remote protocol and command/status interpretation, and demonstrate the intended application transaction before accepting the link.
-
Can the DH wording in a DCV700 description be assumed to mean DF1 for YPK113A?No. The sources use different platform-specific descriptions. Identify the actual controller installation, remote protocol and retained configuration rather than treating those names as interchangeable electrical or application specifications.
-
What distinguishes a correct SAMI restoration using YPK113A from a connector-only check?Restore the recorded APC mounting, serial circuit and settings, then demonstrate the required SAMI command and status exchange with the intended remote device. Retain that functional result and the accepted application mapping.
Supporting new and legacy automation
-
Please try to be as accurate as possible with your search.
-
We can quote you on 1000s of specialist parts, even if they are not listed on our website.
-
We can't find any results for “”.
Related cases and sourcing guidance
View all case studiesYou May Also Like
Product Browsing History
-
Whatsapp: +86 18030235313
Send us a message. -
sales13@apterpower.com
Complete our online form. -
+86 18030235313
Speak to our team in your native language.