Technical specifications for XO08R1 XOO8R1-B04 1SBP260101R1001
-
Manufacturer:ABB
-
Product Category:PLC Systems
-
Spare Part Number:XO08R1 XOO8R1-B04 1SBP260101R1001
-
Weight:0.22 kg
-
Relay outputs:8
-
Extension logic supply:5 V DC from basic/remote unit
-
Output isolation test:1500 V AC, 1 min
-
Resistive DC load / inrush:2 A / 5 A
-
DC load at L/R 20 ms:2 A
-
DC load at L/R 30 ms:1 A
-
DC load at L/R 40 ms:0.6 A
-
DC load at L/R 60 ms:0.35 A
-
AC-1 contact load:2 A
-
AC-15 contact load:0.5 A
-
Resistive switching frequency:<1 Hz
-
Inductive/lamp switching frequency:<0.2 Hz
-
Minimum contact load:10 mA at 12 V DC
-
AC-1 switching life:1,000,000 cycles
-
AC-15 switching life:100,000 cycles
Information
- XO08R1 is a local extension without its own CS31 bus connection. XO08R2 has a different contact arrangement, while XO08Y1 uses transistor outputs; the similar names do not describe equivalent field interfaces.
Host-based expansion: Output data passes through the local extension connection to the basic or remote unit.
Load-dependent contact duty: Inductive behavior and switching frequency influence relay selection beyond the nominal current.
The logic-side extension supply is provided by the connected basic or remote unit. Field contact circuits must still be reviewed independently, particularly the separate C1 and C2 terminals. Do not infer that all commons are internally linked or that the host logic supply establishes a field-load supply.
Relay capability depends on load type, inrush and switching frequency. The decreasing DC inductive limits are specified for different L/R conditions, and external overload and surge protection are required. Preserve those conditions when comparing a spare with the installed actuator circuit.
XO08R1 XOO8R1-B04 1SBP260101R1001 Original Technical Reference Excerpt
Selected original manufacturer pages for the applicable interfaces and technical data. PDF · 6 pages · 185.3 KB.XO08R1 XOO8R1-B04 1SBP260101R1001 Installation & Commissioning Guide
Local Extension Addressing and Relay-Common Review. Build the replacement decision around the host chain, independent commons and actuator duty rather than treating the module as a standalone bus device. PDF · 2 pages · 92 KB.
Application scope: Choose the relay execution and its commons/load protection from the wiring duty. XO08R2 and XO08Y1 change the field-output arrangement.
Local basic-unit outputs
Extend an eligible Series 40/50 basic unit through the local chain. Retain the module order and I/O assignment used by the application.ICMK14 remote expansion
Place the relay extension behind the extensible remote unit. The remote unit, rather than XO08R1, supplies the CS31 station relationship.Separated field commons
Keep the C1 and C2 circuits independent as shown in the installation drawing. Review any commoning links before transferring field supplies.Inductive actuator duty
Compare the actuator L/R and required switching rate with the relay limits. Retain external suppression and overload protection for the actual circuit.
The manufacturer prohibits connecting or disconnecting local extensions under power.
Capture the host, neighboring extensions and application address assignment.
Do not add a commoning link from an assumption about another output module.
Use the current limit for the actual L/R duty and switching frequency.
Inspect the overload and surge-protection components assigned to relay circuits.
Prove the required actuator state at the actual circuit rather than only checking an output command.
Alternative Names
Technical notes
Bus boundary: XO08R1 uses the local extension interface and is not an independent CS31 station.
Common arrangement: C1 and C2 are independent; preserve the actual field-circuit separation.
Minimum-load decision: A low-current electronic input must be checked against the relay’s minimum contact load; the maximum current rating does not establish reliable low-level switching.
FAQ View All FAQ
-
Can XO08R1 XOO8R1-B04 1SBP260101R1001 connect directly as an independent CS31 remote station?No. It is a local extension without a CS31 system-bus connection. Use the documented basic unit or extensible ICMK14 remote unit and preserve the local-chain assignment.
-
Can C1 and C2 on XO08R1 XOO8R1-B04 1SBP260101R1001 be assumed to be internally common?No. The manufacturer identifies them as independent. Compare their field supplies and any intentional links with the installed drawing before transferring wires.
-
Why is an inductive load acceptable at one current but not another on XO08R1 XOO8R1-B04 1SBP260101R1001?The limit changes with the load L/R time constant. Compare the actuator duty with the applicable manufacturer row and retain its external protection rather than applying only the resistive current figure.
-
Is XO08R2 an automatic relay replacement for XO08R1 XOO8R1-B04 1SBP260101R1001?No. R2 has a different normally-open/changeover contact arrangement. Compare channel contacts, commons and required load duty before considering the change.
-
Can the host remain powered while XO08R1 XOO8R1-B04 1SBP260101R1001 is exchanged?No. The manufacturer explicitly prohibits connecting or disconnecting the local extensions under power. Establish the approved shutdown state before disturbing the chain.
-
Does the logic supply of XO08R1 XOO8R1-B04 1SBP260101R1001 determine the voltage switched by its contacts?No. The host supplies extension logic, while the relay contacts belong to separately designed field circuits. Identify the field voltage and contact duty independently.
-
Why can XO08R1 XOO8R1-B04 1SBP260101R1001 switch a test lamp yet behave unreliably with a low-current electronic input?Compare the receiving input with the specified minimum contact load, as well as the maximum load. A test lamp and a very small electronic burden represent different contact conditions; validate the intended circuit rather than the lamp result alone.
-
How should nuisance contact wear on XO08R1 XOO8R1-B04 1SBP260101R1001 be investigated?Check load category, inrush, inductive L/R and switching rate together with external suppression. A current below the resistive rating can still exceed the documented inductive duty or permitted operating frequency.
Supporting new and legacy automation
-
Please try to be as accurate as possible with your search.
-
We can quote you on 1000s of specialist parts, even if they are not listed on our website.
-
We can't find any results for “”.
Related cases and sourcing guidance
View all case studiesYou May Also Like
Product Browsing History
-
XO08R1 XOO8R1-B04 1SBP260101R1001Product Details -
330104-00-10-20-12-05Product Details -
330101-00-10-10-02-05Product Details -
330101-00-30-05-02-00Product Details -
330103-00-03-05-01-05Product Details -
330102-00-60-05-02-05Product Details -
07NG63R1 GJV3074313R1Product Details -
07KP64 GJR5240600R0101Product Details -
07EA61R1 GJV3074351R1Product Details -
330130-040-03-CNProduct Details
-
Whatsapp: +86 18030235313
Send us a message. -
sales13@apterpower.com
Complete our online form. -
+86 18030235313
Speak to our team in your native language.