Technical specifications for 330103-00-03-05-01-05
-
Manufacturer:Bently Nevada
-
Product Category:Machinery Monitoring Systems
-
Spare Part Number:330103-00-03-05-01-05
-
Weight:0.05 kg
-
Tariff Code:8537101190
-
Probe family:3300 XL 8 mm
-
Mounting thread:M10 x 1
-
Mounting form:forward mount
-
Cable armor:No armor
-
Unthreaded length:0 mm
-
Overall case length:30 mm
-
Total probe length:0.5 m
-
Connector and cable:Miniature ClickLoc with connector protector, standard cable
-
Approval selection:Multiple approvals
-
Nominal probe resistance:7.45 +/-0.50 ohm
-
Matched-system linear range:2.0 mm (80 mil)
-
Matched-system scale factor:7.87 V/mm (200 mV/mil)
-
Recommended radial gap:Approximately 1.27 mm at -9 V DC
-
Matched-system frequency response:0 to 10 kHz, +0/-3 dB
-
Minimum flat target diameter:15.2 mm
-
Probe cable impedance:75 ohm triaxial
-
Probe tip material:PPS
-
Probe case material:AISI 303 or 304 stainless steel
-
Minimum cable bend radius:25.4 mm
-
Standard probe temperature:-52 to +177 deg C
Information
- This compact metric probe combines the shortest selected case in the batch with a protected miniature ClickLoc joint, making mechanical reach and protector clearance the primary fit decisions.
Protected termination: 0.5 m standard lead with miniature ClickLoc connector and connector protector.
Approval package: The final 05 option selects the documented multiple-approval configuration.
Option 01 adds a connector protector around the standard-cable miniature ClickLoc joint. The protector needs its own radial and axial clearance, and the unarmored 0.5 m lead must still be supported so the protector is not used as strain relief.
The complete 3300 XL 8 mm chain provides the documented 2.0 mm range and 7.87 V/mm scale under the specified target and calibration conditions. For this short probe, connector cleanliness, target clearance and repeatable mounting datum are the decisive acceptance checks.
-
Bently Nevada 330103-00-03-05-01-05 official technical excerpt
Selected manufacturer pages covering the applicable family, technical data and exact order-code fields. -
Bently Nevada 330103-00-03-05-01-05 engineering guide
Apter Power installation, configuration, diagnostic and acceptance guidance.
Platform applications: The uses below require the documented 3300 XL 8 mm proximity transducer system companion components and approved machine drawing.
-
Compact metric bearing point
Use in an approved M10 x 1 housing where a 30 mm case reaches the shaft without an added unthreaded standoff. -
Protected junction enclosure
Use where the option 01 connector protector can remain accessible and dry inside a small local enclosure. -
Short-lead thrust measurement
Apply to an axial target only after confirming that the 0.5 m lead reaches the companion cable without tension. -
Metric installed-base renewal
Match the 30 mm case, protected standard connector and multiple-approval suffix when renewing the channel.
The 03 metric case code represents 30 mm and must not be substituted with the longer inch-coded 330101 geometry.
The protector increases joint envelope; verify cover, bracket and neighboring cable clearance before installation.
Support the unarmored 0.5 m lead separately so the protector and ClickLoc contacts carry no tensile load.
Remove debris and verify usable M10 x 1 thread depth before seating the zero-unthreaded case.
Photograph the delivered final 05 marking before the probe is enclosed or routed.
After setting gap, compare static Proximitor voltage and controlled monitor indication with the accepted record.
Alternative Names
Technical notes
Metric mounting: Confirm the M10 x 1 port, 30 mm case clearance and zero-unthreaded datum before setting the target gap.
Protector envelope: Allow space to seat and inspect the connector protector without bending or twisting the 0.5 m lead.
Approval identity: Keep the exact final 05 marking with the maintenance record; approval on an adjacent 330103 code is not transferable.
FAQ View All FAQ
-
How is the 03 case code on 330103-00-03-05-01-05 interpreted?For this metric 330103 order structure it represents a 30 mm overall case, not 3.0 in; confirm the metric drawing before fit.
-
What extra clearance must be reserved for 330103-00-03-05-01-05?Allow room around the miniature ClickLoc connector protector for seating, inspection and removal without bending the short lead.
-
Why can a visually similar 330101 probe not replace 330103-00-03-05-01-05 directly?The M10 x 1 metric thread, 30 mm case coding and protector selection differ from the inch-thread order structure and change mechanical fit.
-
How should the 0.5 m lead of 330103-00-03-05-01-05 be supported?Route it to the mating extension cable without tension, maintain bend radius and clamp the cable so the protected joint is not a load point.
-
What approval evidence belongs with 330103-00-03-05-01-05?Retain a photograph of the complete marking showing the final 05 option and compare it with the project approval requirement.
-
What does a 7.45 +/-0.50 ohm reading establish for 330103-00-03-05-01-05?It is a useful probe-and-lead diagnostic reference; it does not establish the installed gap or matched-system scale.
-
Which commissioning observation is most sensitive to a mounting error on 330103-00-03-05-01-05?An incorrect port depth or case datum shifts the static gap voltage, so compare the as-left Proximitor value with the approved mechanical position.
-
When should 330103-00-03-05-01-05 be rejected before energization?Reject it if the metric thread, case code, protected connector, approval marking or companion-chain length differs from the maintenance record.
Supporting new and legacy automation
-
Please try to be as accurate as possible with your search.
-
We can quote you on 1000s of specialist parts, even if they are not listed on our website.
-
We can't find any results for “”.
Related cases and sourcing guidance
View all case studiesYou May Also Like
Product Browsing History
-
330103-00-03-05-01-05Product Details -
330102-00-60-05-02-05Product Details -
07NG63R1 GJV3074313R1Product Details -
07KP64 GJR5240600R0101Product Details -
07EA61R1 GJV3074351R1Product Details -
330130-040-03-CNProduct Details -
190501-07-00-04Product Details -
330500-07-02Product Details -
21747-045-00Product Details -
TLZ07-DAProduct Details
-
Whatsapp: +86 18030235313
Send us a message. -
sales13@apterpower.com
Complete our online form. -
+86 18030235313
Speak to our team in your native language.