Match the complete marking
Include 330101-00-10-10-02-05 and every revision or approval marking visible on the item. Keep the exact reference on your enquiry and quotation.
-
Check the offered item before ordering
Request available label and interface photos. Have your maintenance team compare the offered 330101-00-10-10-02-05 reference with the installed equipment and applicable Bently Nevada documentation.
Technical specifications for 330101-00-10-10-02-05
-
Manufacturer:Bently Nevada
-
Product Category:Machinery Monitoring Systems
-
Spare Part Number:330101-00-10-10-02-05
-
Weight:0.05 kg
-
Tariff Code:8537101190
-
Sensing tip diameter:8 mm
-
Case thread:3/8-24 UNF-2A
-
Unthreaded length:0 in
-
Overall case length:1 in
-
Total probe length:1 m
-
Probe cable impedance:75 ohm
-
Probe DC resistance:7.59 +/-0.50 ohm
-
Minimum cable bend radius:25.4 mm
-
Recommended case torque:11.2 N m
-
Maximum connector torque:0.565 N m
-
Maximum thread engagement:0.563 in
-
Matched-system linear span:2.0 mm
-
Matched-system sensitivity:7.87 V/mm
-
Recommended system gap:1.27 mm / -9 V DC
Information
- Shallow bearing port requires the selected standard-mount body and the 3300 XL 8 mm sensing chain to be reviewed together.
Contactless shaft tracking: The matched eddy-current channel observes position without touching the target.
Compact service path: A detachable local lead permits inspection around the bearing housing.
The unarmored one-metre lead requires local restraint so that housing vibration and maintenance handling do not pull on the cable exit. A separate extension, when fitted, must be selected to match the driver rather than to compensate for insufficient body reach.
The system observes both static position and dynamic displacement. The short mechanical arrangement still requires the same review of side-view metal, target material and gap margin as a longer probe; compact fit does not eliminate those measurement constraints.
-
330101-00-10-10-02-05 Official Technical Reference Excerpt (PDF)
Original XL 8 mm system specifications and applicable probe construction. -
330101-00-10-10-02-05 Installation and Commissioning Guide (PDF)
Apter Power field guide for shallow bearing port, diagnostic decisions and final acceptance evidence.
Application scope: A compact mechanical installation can still experience side-view influence from nearby housing metal. Verify the actual port and target before accepting a probe-only or extension-based electrical arrangement.
Shallow bearing port
A close-to-shaft port needs enough adjustment to establish gap while the short case remains properly retained; avoid installation by tip contact.Compact one-metre channel
For a compact direct-driver arrangement, confirm that the actual driver is the documented one-metre execution before omitting an extension.Shallow-port retention
Where body length is limited, compare final target reach and retained thread together; cable length cannot supply missing mechanical adjustment.Close-housing target exposure
Review conductive metal around the short case when checking a startup offset, particularly if the replacement position differs from the earlier datum.
The short case must reach the target while keeping the locknut securely within its intended mounting region.
Keep the sensing face clear during initial threading; establish the final operating point electrically under the approved stopped-machine procedure.
Provide room beside the short body so the one-metre lead is not bent sharply against the bearing housing.
A one-metre lead can be used only with its documented driver/extension arrangement, not automatically with any Proximitor labeled for a longer chain.
Inspect the tip and response after contact. Normal continuity cannot clear mechanical damage to the sensing face.
Compare the rest position, connector condition and installed gap before assigning the entire offset to machine movement.
Alternative Names
Technical notes
Short-case fit: The short body has limited mechanical adjustment. A suitable electrical chain cannot correct inadequate reach or insecure retention in a deep port.
Contact damage: Tip impact changes the acceptance question from continuity to sensing integrity; verify response before reusing a probe suspected of contacting the shaft.
Compact-port influence: Surrounding conductive metal can affect even a short, apparently well-fitting probe. Compare exposure and final target response after the housing is assembled.
FAQ View All FAQ
-
What proves that the short body of 330101-00-10-10-02-05 can reach the target?Compare port depth, locknut seating and required sensing gap before installation. Do not accept a short body that reaches the target only with inadequate thread retention.
-
Can an extension cable compensate for insufficient mechanical reach of 330101-00-10-10-02-05?No. An extension changes the electrical route, not the distance from the mounting port to the sensing tip. Select the correct mechanical body separately.
-
How should 330101-00-10-10-02-05 be protected during insertion into a shallow port?Keep the tip clear of the target while engaging the thread, then set gap by the approved stopped-machine procedure. Avoid driving the sensing face into the shaft.
-
Why can a shallow counterbore still affect 330101-00-10-10-02-05?Nearby conductive walls can enter the sensing field even when the port is short. Compare tip exposure and surrounding metal with the family side-view data.
-
How is a direct one-metre installation using 330101-00-10-10-02-05 distinguished from a five-metre channel?Read the Proximitor length identity and trace whether an extension is present. The same one-metre probe does not make the two driver calibrations interchangeable.
-
What should be checked if 330101-00-10-10-02-05 indicates a large startup offset?Compare final mechanical gap, connector condition, target location and the recorded shaft rest position. Resolve installation changes before attributing the entire offset to machine movement.
-
Can 330101-00-10-10-02-05 be used with a contacting shaft surface?The probe is noncontacting. A rub or impact can damage the tip and invalidate the measured response; investigate clearance and inspect the probe after contact.
-
How should channel alarm settings be handled after replacing 330101-00-10-10-02-05?Restore the approved channel configuration and validate polarity, gap and operating response. Changing a probe does not justify arbitrary alarm changes to hide an installation discrepancy.
Supporting new and legacy automation
-
Please try to be as accurate as possible with your search.
-
We can quote you on 1000s of specialist parts, even if they are not listed on our website.
-
We can't find any results for “”.
Related cases and sourcing guidance
View all case studiesYou May Also Like
Product Browsing History
-
330101-00-10-10-02-05Product Details -
330101-00-30-05-02-00Product Details -
330103-00-03-05-01-05Product Details -
330102-00-60-05-02-05Product Details -
07NG63R1 GJV3074313R1Product Details -
07KP64 GJR5240600R0101Product Details -
07EA61R1 GJV3074351R1Product Details -
330130-040-03-CNProduct Details -
190501-07-00-04Product Details -
330500-07-02Product Details
-
Whatsapp: +86 18030235313
Send us a message. -
sales13@apterpower.com
Complete our online form. -
+86 18030235313
Speak to our team in your native language.