Product Describe:

Bently Nevada 330101-00-10-10-02-05 is a standard-mount unarmored 3300 XL 8 mm probe with 3/8-24 UNF-2A threads, 1 in case and 1 m total probe length.
  • Manufacturer part number
    330101-00-10-10-02-05
  • Shipping
    Swift global dispatch
  • Condition
    New, original product
  • Shipping size (est.)
    1.6cm x 1.4cm x 117cm
  • Country of Origin
    USA
Get a quick price for 330101-00-10-10-02-05
E-mail *
Mobile
Company
Content *
Quantity *
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)
For more information on how your data is processed and stored by Apterpower please read our privacy policy

What happens after you enquire

  • 0

    Review your reference

    Send the full marking, quantity and label photos. We review the item and any version details that need clarification.

  • 1

    Confirm the offer

    Check the quoted reference, condition, included items and expected dispatch date before approving your order.

  • 2

    Arrange dispatch

    Confirm delivery details and receive the tracking number when it becomes available.

  • Match the complete marking

    Include 330101-00-10-10-02-05 and every revision or approval marking visible on the item. Keep the exact reference on your enquiry and quotation.

  • Check the offered item before ordering

    Request available label and interface photos. Have your maintenance team compare the offered 330101-00-10-10-02-05 reference with the installed equipment and applicable Bently Nevada documentation.

Technical specifications for 330101-00-10-10-02-05

  • Manufacturer:
    Bently Nevada
  • Product Category:
    Machinery Monitoring Systems
  • Spare Part Number:
    330101-00-10-10-02-05
  • Weight:
    0.05 kg
  • Tariff Code:
    8537101190
  • Sensing tip diameter:
    8 mm
  • Case thread:
    3/8-24 UNF-2A
  • Unthreaded length:
    0 in
  • Overall case length:
    1 in
  • Total probe length:
    1 m
  • Probe cable impedance:
    75 ohm
  • Probe DC resistance:
    7.59 +/-0.50 ohm
  • Minimum cable bend radius:
    25.4 mm
  • Recommended case torque:
    11.2 N m
  • Maximum connector torque:
    0.565 N m
  • Maximum thread engagement:
    0.563 in
  • Matched-system linear span:
    2.0 mm
  • Matched-system sensitivity:
    7.87 V/mm
  • Recommended system gap:
    1.27 mm / -9 V DC

Information

Overview Downloads Applications / Compatibility Product Precautions
  • Shallow bearing port requires the selected standard-mount body and the 3300 XL 8 mm sensing chain to be reviewed together.
Close-port installation: The short body serves a sensing point near the mounting surface.
Contactless shaft tracking: The matched eddy-current channel observes position without touching the target.
Compact service path: A detachable local lead permits inspection around the bearing housing.
The short 1.0 in body is intended for an imperial port close to the measured shaft. Compared with a longer case, it leaves less adjustment reach; the port depth must allow the sensing face to reach its operating gap while the locknut remains correctly engaged.

The unarmored one-metre lead requires local restraint so that housing vibration and maintenance handling do not pull on the cable exit. A separate extension, when fitted, must be selected to match the driver rather than to compensate for insufficient body reach.

The system observes both static position and dynamic displacement. The short mechanical arrangement still requires the same review of side-view metal, target material and gap margin as a longer probe; compact fit does not eliminate those measurement constraints.
Controller platform reference: 3300 XL 8 mm transducer system. Use the matched installation.
Use the original technical reference for specifications and the separate installation guide for 330101-00-10-10-02-05 field work.
The technical reference retains selected original manufacturer pages. The separate installation guide supports field verification for 330101-00-10-10-02-05.
Prepare Bently Nevada 330101-00-10-10-02-05 for its configured installation using these product-specific checks.
Check retained thread at working gap

The short case must reach the target while keeping the locknut securely within its intended mounting region.

Do not use shaft contact as a stop

Keep the sensing face clear during initial threading; establish the final operating point electrically under the approved stopped-machine procedure.

Relieve the first cable turn

Provide room beside the short body so the one-metre lead is not bent sharply against the bearing housing.

Distinguish probe from system length

A one-metre lead can be used only with its documented driver/extension arrangement, not automatically with any Proximitor labeled for a longer chain.

Investigate a suspected rub

Inspect the tip and response after contact. Normal continuity cannot clear mechanical damage to the sensing face.

Assess startup offset at the same datum

Compare the rest position, connector condition and installed gap before assigning the entire offset to machine movement.

Alternative Names

330101 00 10 10 02 05 330101/00/10/10/02/05

Technical notes

Short-case fit: The short body has limited mechanical adjustment. A suitable electrical chain cannot correct inadequate reach or insecure retention in a deep port.

Contact damage: Tip impact changes the acceptance question from continuity to sensing integrity; verify response before reusing a probe suspected of contacting the shaft.

Compact-port influence: Surrounding conductive metal can affect even a short, apparently well-fitting probe. Compare exposure and final target response after the housing is assembled.

FAQ View All FAQ

  • What proves that the short body of 330101-00-10-10-02-05 can reach the target?
    Compare port depth, locknut seating and required sensing gap before installation. Do not accept a short body that reaches the target only with inadequate thread retention.
  • Can an extension cable compensate for insufficient mechanical reach of 330101-00-10-10-02-05?
    No. An extension changes the electrical route, not the distance from the mounting port to the sensing tip. Select the correct mechanical body separately.
  • How should 330101-00-10-10-02-05 be protected during insertion into a shallow port?
    Keep the tip clear of the target while engaging the thread, then set gap by the approved stopped-machine procedure. Avoid driving the sensing face into the shaft.
  • Why can a shallow counterbore still affect 330101-00-10-10-02-05?
    Nearby conductive walls can enter the sensing field even when the port is short. Compare tip exposure and surrounding metal with the family side-view data.
  • How is a direct one-metre installation using 330101-00-10-10-02-05 distinguished from a five-metre channel?
    Read the Proximitor length identity and trace whether an extension is present. The same one-metre probe does not make the two driver calibrations interchangeable.
  • What should be checked if 330101-00-10-10-02-05 indicates a large startup offset?
    Compare final mechanical gap, connector condition, target location and the recorded shaft rest position. Resolve installation changes before attributing the entire offset to machine movement.
  • Can 330101-00-10-10-02-05 be used with a contacting shaft surface?
    The probe is noncontacting. A rub or impact can damage the tip and invalidate the measured response; investigate clearance and inspect the probe after contact.
  • How should channel alarm settings be handled after replacing 330101-00-10-10-02-05?
    Restore the approved channel configuration and validate polarity, gap and operating response. Changing a probe does not justify arbitrary alarm changes to hide an installation discrepancy.