Speak to a sourcing specialist
sales13@apterpower.com

AAI135-H03 S1

Isolated Analog Input Module
Product image is representative; revision or series may vary. Contact us to request a specific version.

Product Describe:

This HART-capable eight-input FIO module combines isolated current channels with the G3 and extended-temperature order option. The environmental suffix applies to the selected hardware execution within a compatible node installation.
  • Manufacturer part number
    AAI135-H03 S1
  • Shipping
    Swift global dispatch
  • Condition
    New, original product
  • Shipping size (est.)
    3.2cm x 10.6cm x 13cm
  • Country of Origin
    Japan
Get a quick price for AAI135-H03 S1
E-mail *
Mobile
Company
Content *
Quantity *
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)
For more information on how your data is processed and stored by Apterpower please read our privacy policy

What happens after you enquire

  • 0

    Review your reference

    Send the full marking, quantity and label photos. We review the item and any version details that need clarification.
  • 1

    Confirm the offer

    Check the quoted reference, condition, included items and expected dispatch date before approving your order.
  • 2

    Arrange dispatch

    Confirm delivery details and receive the tracking number when it becomes available.
  • Match the complete marking

    Include AAI135-H03 S1 and every revision or approval marking visible on the item. Keep the exact reference on your enquiry and quotation.
  • Check the offered item before ordering

    Request available label and interface photos. Have your maintenance team compare the offered AAI135-H03 S1 reference with the installed equipment and applicable Yokogawa documentation.

Technical specifications for AAI135-H03 S1

  • Manufacturer:
    Yokogawa
  • Product Category:
    DCS Systems
  • Spare Part Number:
    AAI135-H03 S1
  • Weight:
    0.25 kg
  • Tariff Code:
    8537101190
  • Analog inputs:
    8 channels
  • Input signal:
    4–20 mA DC
  • Input current limit:
    25 mA
  • Input accuracy:
    ±16 µA
  • Data update:
    10 ms
  • Powered input resistance:
    290 Ω at 20 mA; 450 Ω at 4 mA
  • Unpowered input resistance:
    ≥500 kΩ
  • Transmitter voltage at 20 mA:
    ≥15.0 V
  • Transmitter voltage at zero current:
    ≤29.3 V
  • 5 V supply consumption:
    360 mA maximum
  • 24 V supply consumption:
    450 mA maximum
  • Temperature drift:
    ±16 µA / 10°C
  • Field/system withstand:
    500 V AC, 1 minute
  • Channel/channel withstand:
    500 V AC, 1 minute; complete MIL cable assembly subject to cable rating
  • Temperature option:
    −20 to +70°C; compatible host/node required
  • Atmosphere option:
    ISA Standard G3

Information

Overview Downloads Applications / Compatibility Product Precautions
  • H03 selects the environmental execution needed when the basic AAI135 input arrangement must be used under the documented extended conditions.
Exposure option: ISA Standard G3 and the −20 to +70°C temperature option are selected.
Signal architecture: Eight field inputs remain separately isolated; H03 does not add output channels.
Installation scope: The compatible node and external cable retain their own environmental and insulation limits.
AAI135-H03 S1 retains the eight-input topology of H00 while selecting the documented G3 and temperature option. An H00 spare should therefore not be accepted solely because it fits the slot and passes a room-temperature current test. H03 specifies the G3 and extended-temperature selection, with a -20 to +70°C module envelope in the qualified installation. This does not extend the ratings of terminal assemblies, node supplies or field instruments.

Environmental qualification and electrical isolation solve different problems. G3 addresses the selected atmospheric option; the isolated input construction separates channel circuits. Neither removes the need to account for field-cable insulation, external barrier design or transmitter supply headroom. The input temperature influence is ±16 µA per 10°C. Evaluate that influence over the actual cabinet temperature change, separately from the ±16 µA reference input accuracy and the calibrator contribution.

HART communication shares the current-input installation but relies on the supported digital path through the FIO node. On a remote node, the EB401 firmware requirement must be met before the analogue and digital portions can be accepted as one commissioned channel. The 500 V AC, one-minute field/system and channel/channel withstand figures describe module isolation. Keep external returns separate and check the actual MIL cable rating before treating the complete harness as equally isolated.
Controller platform reference: CENTUM FIO analog I/O. Match node, termination and loop design.
System and supply context: The H03 execution is intended for an eligible FIO node using eight isolated current inputs and HART-enabled field instruments.

Integration boundary: Qualify the environmental chain from the module through its node, termination and cable, rather than assigning the module option to the whole cabinet. Choose the H03 execution for the documented environmental duty while retaining the legacy HART node route. The EB401 Rev 2-or-later remote condition and the exact S1 terminal execution are separate acceptance checks.
Verify the H03 environmental option independently of channel operation. Record cabinet temperature; budget 5 V and 24 V node loads separately, as H03 adds no supply capacity.
Reject a basic-type substitution

Check the H03 marking before accepting an H00 unit as an environmental replacement.

Check the node rating

Confirm that the installed remote/local node supports the required ambient conditions.

Keep enclosure protection

The G3 option does not establish a cabinet ingress-protection rating.

Review cable temperature limits

A qualified module does not extend the rating of an existing terminal cable.

Verify power-mode pins

Restore the correct per-channel transmitter arrangement after any terminal work.

Test analog and HART paths

Record current accuracy and HART communication separately from the intended maintenance station.

Alternative Names

Yokogawa AAI135-H03 S1 Yokogawa AAI135 H03 S1

Technical notes

Environmental chain: Module ambient capability must be checked alongside the node and termination ratings, not used as a blanket cabinet rating.

Field isolation: The interchannel withstand specification assumes the applicable external cable electrical limits.

Transmitter headroom: The guaranteed module-terminal voltage still needs a deduction for field wiring and any external isolation interface.

FAQ View All FAQ

  • Is a successful room-temperature test enough to accept AAI135-H03 S1 for an H03 installation?
    No. A loop test checks electrical behavior at the test condition. Separately verify the H03 marking, qualified node and environmental requirements that motivated that option.
  • Does the G3 option on AAI135-H03 S1 replace cabinet sealing or environmental control?
    No enclosure rating follows from the G3 suffix. Compare the cabinet’s protection and atmosphere requirements with the module’s selected environmental option.
  • Can AAI135-H03 S1 share its extended-temperature rating with any attached MIL harness?
    The cable has its own temperature and insulation specification. Verify the actual assembly limits before relying on the module rating at the installation ambient.
  • How should a 20°C ambient change be considered when checking AAI135-H03 S1?
    The stated drift of ±16 µA per 10°C gives a ±32 µA drift contribution for a 20°C change. It is separate from the initial accuracy and test-equipment uncertainty. Record the calibration and operating temperatures rather than accepting a room-temperature result as an unchanged error budget across the H03 operating envelope.
  • Does the one-minute insulation test for AAI135-H03 S1 define a continuous working voltage?
    No. A 500 V AC withstand test for one minute is a dielectric test condition, not permission to operate a field circuit continuously at that voltage. Check the actual loop voltage and the insulation limits of its termination and cable; the H03 environmental selection does not turn that test figure into an operating rating.
  • Does the 10 ms update of AAI135-H03 S1 guarantee 100 HART transactions per second?
    No. The 10 ms figure describes the analog data-update period, not a HART transaction-time rating or an end-to-end control-loop bandwidth. Test analog acquisition and digital instrument access as separate functions. Include the actual host scan, filtering and communication configuration before assigning an application response-time requirement.
  • Why is a fixed 290-ohm substitute load incomplete for testing AAI135-H03 S1?
    The powered input includes a protection-circuit voltage drop, so its terminal burden varies with current. The published endpoints correspond to approximately 1.8 V at 4 mA and 5.8 V at 20 mA. Use the actual module or a justified burden model; one fixed resistor cannot reproduce both endpoint conditions.
  • How can the independent channels of AAI135-H03 S1 be checked after rewiring?
    Exercise inputs one at a time and compare the intended channel with adjacent indications. Also inspect unwanted common connections in the termination; an individual current reading does not verify circuit separation.
SPEAK TO OUR TEAM
Let’s find the right solution for you.
Send us the part number, quantity and delivery destination. Our team will help confirm availability and lead time.
  • Whatsapp: +86 18030235313

    Send us a message.
  • sales13@apterpower.com

    Complete our online form.
  • +86 18030235313

    Speak to our team in your native language.