Technical specifications for 8920-PS-DC
-
Manufacturer:MTL Insturments Group
-
Product Category:DCS Systems
-
Spare Part Number:8920-PS-DC
-
Weight:0.8 kg
-
Tariff Code:8537101190
-
Input voltage:18.5 to 36 V DC
-
Output voltage:12 V DC +/-5%
-
Output current:5 A
-
Input/output isolation:250 V AC rms; tested at 1,500 V AC rms
-
Efficiency at 18.5 V input:76% at 4.1 A
-
Efficiency at 24 V input:78% at 3.3 A
-
Efficiency at 36 V input:76.5% at 2.1 A
-
Operating temperature, 60% load:-40 to +70 deg C
-
Operating temperature, full load:-40 to +55 deg C optimum orientation
-
Storage temperature:-40 to +85 deg C
-
Relative humidity:5 to 95% noncondensing
-
Vibration:2 g at 10 to 100 Hz
-
Shock:10 g, 11 ms
-
MTBF:80,000 hours at 50 deg C ambient
-
Ingress protection:IP20
-
Terminal cable size:2.5 mm2 maximum
Information
- The complete 8920-PS-DC identity establishes the hardware selection; installation still depends on the documented host, companion components and project configuration.
Load-budget control: Available module count is governed by the actual 12 V load, not a fixed slot total.
Redundancy proof: An n+1 design requires controlled removal and failure-alarm testing.
Its 5 A output can support different numbers of I/O modules depending on the installed module mix. Calculate the actual load and redundancy margin rather than assuming every node has the same capacity.
After installation, verify input polarity, 12 V output, load sharing, Bus Interface Module diagnostics and the approved n+1 response. Do not disturb live intrinsically safe circuits outside the site procedure.
-
MTL 8920-PS-DC technical reference
Apter Power reference with verified manufacturer data and exact-model applicability. -
MTL 8920-PS-DC engineering guide
Apter Power installation, configuration, diagnostic and acceptance guidance.
Platform applications: The uses below depend on the installed controller configuration and approved system design.
-
MTL8000 IS node supply
Power I/O modules connected to intrinsically safe field circuits. -
Redundant node power
Use an additional supply in an approved n+1 arrangement. -
Load-shared expansion
Distribute the calculated 12 V load across multiple power modules. -
Node-services integration
Mount on compatible MTL8000 carrier positions and report failure to the BIM.
Match every field of 8920-PS-DC with the approved spare-parts record before installation.
Use grounded handling, antistatic packaging and protected work surfaces for exposed electronics.
Confirm connector keying, slot assignment, supply and companion hardware before energizing.
Record switches, firmware, parameters, terminal assignments and as-found diagnostics before removal.
Check contamination, corrosion, ventilation, vibration and cabinet temperature before fitting the replacement.
Complete the manufacturer and site acceptance procedure, then retain the as-left result with the maintenance record.
Alternative Names
Technical notes
Carrier relationship: Mount the module only on the documented MTL8000 carrier, retain input polarity and feeder protection, and verify the carrier contacts before energizing.
Load and redundancy: The 12 V DC output is rated 5 A; calculate the actual I/O-module load and reserve capacity before applying load sharing or n+1 redundancy.
Technical reference: Eaton MTL8000 2/x power-supplies overview and 8920-PS-DC technical data.
FAQ View All FAQ
-
How should the load budget for 8920-PS-DC be calculated?Sum the documented 12 V demand of every installed I/O module, include operating margin and verify the result against each supply and the required redundancy state.
-
What should be checked if 8920-PS-DC reports failure but 24 V DC is present?Measure input at the carrier, inspect carrier contacts, confirm 12 V output and load, then review Bus Interface Module diagnostics.
-
How is n+1 redundancy of 8920-PS-DC proved?Under the approved process condition, remove or isolate one supply, verify the remaining modules carry the load and confirm the failure indication reaches the BIM.
-
Why can the number of modules powered by 8920-PS-DC vary?MTL8000 I/O types have different current demands, so the 5 A capacity supports a module count determined by the actual mix.
-
What evidence should be recorded before replacing 8920-PS-DC?Capture the complete nameplate, installed slot or mounting position, companion hardware, wiring identifiers and the accepted operating baseline for the mtl8000 intrinsically safe i/o power-supply module.
-
How should an intermittent fault around 8920-PS-DC be isolated?Separate field wiring, connector, supply, grounding, configuration and host-system causes. Reproduce the symptom under a controlled test and change only one variable at a time.
-
What configuration evidence should be retained after commissioning 8920-PS-DC?Retain the hardware identity, firmware or parameter record where applicable, channel assignment, as-left measurements, alarm or diagnostic state and the approved functional-test result.
-
When should 8920-PS-DC be rejected during incoming inspection?Quarantine the item if the complete marking, connector keying, board revision, protective coating, terminal condition or required companion hardware differs from the approved replacement record.
Supporting new and legacy automation
-
Please try to be as accurate as possible with your search.
-
We can quote you on 1000s of specialist parts, even if they are not listed on our website.
-