    Once the quotation and purchasing details are agreed, your contact will coordinate the order and available dispatch information.

Technical specifications for F860-CA

  • Manufacturer:
    MTL Insturments Group
  • Product Category:
    DCS Systems
  • Spare Part Number:
    F860-CA
  • Estimated shipping dimensions:
    29.4x12x5cm
  • Weight:
    0.32 kg
  • Tariff Code:
    8537101190
  • Counliy of origin:
    Xiamen, Fujian, China
  • IOTA configuration:
    Unpopulated
  • Fieldbus segments:
    8
  • Power modules:
    F801; F802
  • Module positions:
    2
  • Input voltage:
    19.2 to 30.0 Vdc
  • Input current at 24 Vdc:
    3.5 A F801; 6 A F802
  • Power dissipation at 24 Vdc:
    20 W F801; 24 W F802
  • Segment output voltage:
    21.5 to 24.0 Vdc F801; 28.0 to 30.0 Vdc F802
  • Design current per segment:
    0 to 350 mA F801; 0 to 500 mA F802
  • Current limit:
    >370 mA F801; >520 mA F802
  • Minimum segment load:
    0 mA
  • Input isolation:
    250 Vac rms withstand
  • Segment isolation:
    200 Vdc withstand
  • Alarm contact rating:
    1 A maximum at 30 Vdc
  • Alarm contact state:
    Normally closed
  • Segment alarm threshold:
    <19 Vdc F801; <24 Vdc F802
  • Supply conductor:
    0.14 to 2.5 mm2
  • FIM connection:
    Two 16-way multipin FCAB-0x cables
  • Segment termination:
    One automatic termination per segment
  • Ingress protection:
    IP20
  • Operating temp, full load:
    -40 to +65 degC F801; -40 to +50 degC F802
  • Operating temp, 60% load:
    -40 to +65 degC
  • Storage temperature:
    -40 to +85 degC
  • Physical networks:
    IEC 61158-2; FOUNDATION fieldbus H1; PROFIBUS PA
  • EMC compliance:
    EN 61326:1998
  • Mounting:
    Honeywell Series C I/O channel; vertical

Information

Overview Manuals Common Applications Product Precautions
MTL F860-CA is an unpopulated eight-segment IOTA for the F860 redundant fieldbus power system. It links paired F801 or F802 power modules to Honeywell Series C Fieldbus Interface Modules and field segments.
  • Distributes conditioned power to eight independent fieldbus H1 segments
  • Maintains segment termination with one or two installed F80x power modules
  • Transfers individual segment-fault status to the Series C FIM IOTA
  • Accepts an optional physical-layer diagnostics module for all eight segments

F860-CA installs with Honeywell Series C 4-link FIM IOTA, One or two F801 or F802 power modules, Series C channel busbars or dual external 24 Vdc supplies, Two FCAB-0x system cables and eight fieldbus H1 segments in an engineered F860 Redundant Fieldbus Power System configuration.

The commissioning workflow covers installed-hardware matching, controlled start-up and functional verification for this unpopulated eight-segment fieldbus iota.

Important Notice: Confirm the complete F860-CA marking, installed-system configuration, field connections and controlled functional test before commissioning or replacement.

Apter Power F860-CA Manuals and Guides
Apter Power F860-CA Product Technical Reference PDFMTL Instruments Group F860-CA Official Manual PDF
The first document is an Apter Power model-specific technical reference. The second supports model-specific installation, configuration and engineering verification.
Redundant FOUNDATION fieldbus segment powerCombines the unpopulated IOTA, a Series C 4-link FIM IOTA and two FCAB-0x cables in a new eight-segment cabinet build.
Series C process-instrument networksUses the two module positions for a simplex F801/F802 installation or an engineered redundant power-module arrangement.
High-availability eight-segment cabinetsAccepts dual external 24 Vdc supplies when the installation does not use Series C channel busbars.
Fieldbus power and fault-diagnostic modernizationAccommodates the optional F809F-Plus module to observe physical-layer condition across all eight connected segments.
Read the applicable MTL Instruments Group installation instructions before work. Verify F860-CA and the installed F860 Redundant Fieldbus Power System configuration.
1Verify the complete F860-CA marking and its assigned F860 Redundant Fieldbus Power System position before work.
2Isolate the energy associated with Honeywell Series C 4-link FIM IOTA before disconnecting F860-CA.
3Protect the F860-CA connectors and electronic assembly using approved ESD controls.
4Record the as-found One or two F801 or F802 power modules connections and configured assignment before replacement.
5Confirm Series C channel busbars or dual external 24 Vdc supplies matches the approved installation record for F860-CA.
6Restore F860-CA under controlled conditions and review its model-specific diagnostics.
7Complete a documented functional test for redundant foundation fieldbus segment power before release.

Technical notes

Mount F860-CA vertically on the Series C channel, keep the two FCAB-0x links and eight segment identities unchanged, then prove power, alarm transfer and communication on every segment before restoring redundant service.

FAQ View All FAQ

  • What wiring information should be recorded before removing F860-CA?
    Record terminal identifiers, polarity or phase, shields, cable tags and the as-found channel or port assignment for F860-CA.
  • How should engineers validate F860-CA after configuration?
    Restore the documented F860 Redundant Fieldbus Power System assignment, review diagnostics and run a controlled test of its role: distributes conditioned power to eight independent fieldbus h1 segments.
  • Can F860-CA be moved to a different slot or duty without review?
    No. Confirm keying, companion hardware and the approved configuration before assigning F860-CA to another position or function.
  • Which technical value is especially important during F860-CA commissioning?
    Verify Minimum segment load is 0 mA and use the named manufacturer procedure for the controlled functional test.
  • What should be checked if F860-CA does not support series c process-instrument networks after installation?
    Check seating, One or two F801 or F802 power modules, Series C channel busbars or dual external 24 Vdc supplies, field energy and the model-specific diagnostics before replacing additional hardware.
  • What evidence should be retained after F860-CA returns to service?
    Retain the full model identity, as-left connections, configuration, diagnostic result and the final controlled test record for redundant foundation fieldbus segment power.
  • How is F860-CA identified before installation in a F860 Redundant Fieldbus Power System cabinet?
    Match the full F860-CA marking and part number F860-CA to the assigned position and installed Honeywell Series C 4-link FIM IOTA.
  • Which companion hardware must be checked when replacing F860-CA?
    Verify Honeywell Series C 4-link FIM IOTA, One or two F801 or F802 power modules and Series C channel busbars or dual external 24 Vdc supplies against the approved cabinet and project record before fitting the Unpopulated Eight-Segment Fieldbus IOTA.
Related reading

Related cases and sourcing guidance

View all case studies
Manufacturers

Product Browsing History

Revisit the products you recently viewed on Apter Power.
SPEAK TO OUR TEAM
Let’s find the right solution for you.
Send us the part number, quantity and delivery destination. Our team will help confirm availability and lead time.
  • Whatsapp: +86 18030235313

    Send us a message.
  • sales13@apterpower.com

    Complete our online form.
  • +86 18030235313

    Speak to our team in your native language.