Get Parts Quote
Name
Company *
Phone *
Email *
Address
City
State / Province / Region
Zipcode
Country
Quantity *
Part Number *
Manufacturer
Preferred Condition
Additional Information
Cancel

5DLSDL.1000-00

Automation Panel 900 SDL Receiver
In Stock
Ships by Wednesday, October 7
Fast Shipping Available

Product Describe:

B&R 5DLSDL.1000-00 is a automation panel 900 sdl receiver for the documented Control Panels installation.

Ask our team:

Get a quick price for: 5DLSDL.1000-00
Quantity*
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)
For more information on how your data is processed and stored by Apterpower please read our privacy policy.

Technical specifications for 5DLSDL.1000-00

Technical specifications for 5DLSDL.1000-00

  • Manufacturer:
    B&R
  • Product Category:
    HMI
  • Spare Part Number:
    5DLSDL.1000-00
  • Estimated shipping dimensions:
    9.4×5.4×3.2cm
  • Weight:
    0.2 kg
  • Tariff Code:
    8537101190
  • Counliy of origin:
    Austria
  • Component:
    SDL receiver
  • Compatible panels:
    Automation Panel 900
  • Panel input:
    SDL
  • Panel output:
    None
  • Supply:
    24 VDC +/-25%, SELV
  • Nominal current:
    Maximum 4.2 A
  • Power consumption:
    Typically 3 W
  • Fastening torque:
    Maximum 0.5 Nm

Information

Information

Overview Manuals Common Applications Product Precautions
B&R 5DLSDL.1000-00 is a automation panel 900 sdl receiver for the documented Control Panels installation.
  • Provides Smart Display Link reception
  • Uses exact B&R article identity 5DLSDL.1000-00
  • Matches component: SDL receiver
  • Matches compatible panels: Automation Panel 900

The product performs Smart Display Link reception in the documented Automation Panel 900. Installation and commissioning must preserve the exact identity, interfaces and approved configuration.

Important Notice: Confirm B&R 5DLSDL.1000-00, Automation Panel 900, SDL Panel IN connection and 24 VDC supply, wiring, grounding, configuration, companion accessories and controlled commissioning results before service release.

Apter Power 5DLSDL.1000-00 Manuals and Guides

The first document is the model-specific technical and system reference. The second is a distinct field workbook for installation, wiring, commissioning and acceptance records.

Control Panels system maintenance
Restores Smart Display Link reception in the documented installation.
Controlled hardware replacement
Preserves the exact 5DLSDL.1000-00 identity and approved configuration.
Interface verification
Confirms SDL Panel IN connection and 24 VDC supply before energization.
Functional recommissioning
Reviews diagnostics and records the controlled system response.
Read the applicable B&R installation instructions before work. Verify 5DLSDL.1000-00, the installed host system and all configured field interfaces before isolation, wiring or commissioning.
1
Confirm the complete B&R 5DLSDL.1000-00 marking and installed Control Panels position before work.
2
Place the machine or process in the approved maintenance state and isolate every applicable energy source.
3
Record SDL Panel IN connection and 24 VDC supply, terminal assignments, shielding and protective-ground connections before removal.
4
Use ESD controls and protect keyed connectors, terminals and exposed electronics from contamination.
5
Verify component (SDL receiver) against the installed project and connected hardware.
6
Verify compatible panels (Automation Panel 900) and restore only the approved configuration.
7
Energize in the prescribed sequence and review module, host and network diagnostics.
8
Complete a controlled Smart Display Link reception test and retain the acceptance result before production release.

Technical notes

Technical notes

Confirm B&R 5DLSDL.1000-00, Automation Panel 900, SDL Panel IN connection and 24 VDC supply, wiring, grounding, configuration, companion accessories and controlled commissioning results before service release.

FAQS

  • How is the exact 5DLSDL.1000-00 execution identified?
    Match the complete B&R 5DLSDL.1000-00 marking and the controlled installed-position record.
  • What documented role does 5DLSDL.1000-00 perform?
    It performs Smart Display Link reception in the documented Automation Panel 900.
  • Which host must be matched before fitting 5DLSDL.1000-00?
    Match the exact Automation Panel 900 and approved system position.
  • Which interfaces must be recorded for 5DLSDL.1000-00?
    Record SDL Panel IN connection and 24 VDC supply, mounting, shielding, grounding and cable routing.
  • What isolation controls apply to 5DLSDL.1000-00?
    Place the machine or process in the approved maintenance state and isolate every applicable energy source.
  • What must be restored after installing 5DLSDL.1000-00?
    Verify compatible panels (Automation Panel 900) and restore only the approved configuration.
  • What proves 5DLSDL.1000-00 is ready for service?
    Retain diagnostics and a controlled Smart Display Link reception response test.
  • Which manufacturer record supports the 5DLSDL.1000-00 page?
    Automation Panel 900 User's Manual and the official B&R product record for 5DLSDL.1000-00.
Trusted by 5,000+ plants worldwide | Backed by our vast inventory of top-tier control parts, modules and cards, fast shipments are dispatched to cover your urgent needs. ABOUT US >>
Disclaimer: We are not an authorized distributor or distributor of the product manufacturer of this website, The product may have older date codes or be an older series than that available direct from the factory or authorized dealers. Because our company is not an authorized distributor of this product, the Original Manufacturer`s warranty does not apply.While many DCS PLC products will have firmware already installed, Our company makes no representation as to whether a DSC PLC product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Our company also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from our company, its distributors, or any other source. Our company also makes no representations as to your right to install any such firmware on the product. Our company will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.

Product Browsing History

We’re Here When You Need Us

From product insights to customer service needs, our experienced service team will focus on getting you what you need quickly

Enquire

Complete our online form.

Call Us

Speak to one of our team.

Live Chat

Send us a message.