Technical specifications for 1756-WS
-
Manufacturer:HARDY
-
Product Category:PLC Systems
-
Spare Part Number:1756-WS
-
Weight:0.3 kg
-
Tariff Code:8537101190
-
Complete order code:1756-WS
-
Product type:Single-Channel Weigh Scale Module
-
System context:Allen-Bradley ControlLogix chassis platform
-
Channels:1 weigh-scale channel
-
Conversion rate:50 updates per second
-
Selectable averaging:1–255 readings
-
Internal resolution:1:8,388,608
-
Sensor input:Up to eight 350 Ω full Wheatstone-bridge load sensors/cells at 5 V excitation
-
Non-linearity:0.0015% of full scale
-
WAVERSAVER cutoffs:7.50, 3.50, 1.00, 0.50 or 0.25 Hz
-
Excitation monitoring:Current deviation threshold less than ±10% expected
-
Common-mode rejection:110 dB at or below 60 Hz
-
Common-mode voltage range:2.5 VDC maximum to earth ground
-
Backplane input:5 VDC and 24 VDC
-
Backplane current:Less than 1 A at 5 VDC; 0.0125 A at 24 VDC with four 350 Ω load cells
-
Backplane power:Less than 5 W at 5 VDC; less than 0.3 W at 24 VDC with four 350 Ω load cells
-
C2 isolation:1000 VDC minimum from digital section
-
C2 cable length:1000 ft maximum; 250 ft with IT junction box and up to four sensors
-
Load-cell excitation:5 VDC ±1.15 W maximum
-
Operating temperature:0 to 60 °C
-
Storage temperature:-40 to 85 °C
-
Humidity:0–90% non-condensing
-
Diagnostics:WAVERSAVER, C2 calibration, excitation monitoring and Integrated Technician support
-
Temperature coefficient:Less than 0.005% of full scale per °C at Cal-LO and Cal-HI
-
Digital voltmeter accuracy:±2% of full scale
-
Input assembly:Instance 101; size 11
-
Output assembly:Instance 146; size 1
-
Default WAVERSAVER cutoff:1.00 Hz
Information
- 1756-WS occupies a defined service position in the Allen-Bradley ControlLogix chassis platform; approval depends on the complete marking and installed boundary.
Conversion path: 50 updates per second with 1:8,388,608 internal resolution.
Filtering and calibration: WAVERSAVER 0.25–7.50 Hz selections with C2 electronic calibration support.
Within the Allen-Bradley ControlLogix chassis platform, evaluate 1756-WS together with its carrier, terminals, cables and applicable project or hardware settings. Preserve the as-found interface map and revision evidence; a mechanically similar item is not automatically equivalent.
Commissioning 1756-WS should progress from identity and connection checks to controlled power-up, diagnostics and functional proof. Keep final status, test conditions and unresolved exceptions in the handover record.
-
Hardy 1756-WS Official Manual Extract
Original manufacturer excerpt - PDF, 6 pages. Module role, calibration functions, measurement data, backplane limits and environment. -
1756-WS Installation & Commissioning Guide
Apter Power engineering guide - PDF, 5 pages. Replacement sequence, interface checks, commissioning, fault isolation and acceptance record.
Compatibility boundary: Match the complete marking, hardware execution and installed interfaces before replacement.
-
Installed-system replacement
Compare the exact code, host position and connected interfaces with the removed item. -
Planned maintenance
Capture the as-found label, indications and configuration before disturbing the installation. -
Controlled commissioning
Restore documented connections and prove the intended signal, communication or control response. -
Spare qualification
Keep revision, configuration and acceptance evidence with the spare-part record.
Check every token in 1756-WS against the offered label and approved record.
Follow the site procedure for stored energy, field power and electrostatic handling.
Photograph and label carriers, terminals, cables and keying before removal.
Archive applicable Allen-Bradley ControlLogix chassis platform settings before replacement.
Check connectors, terminal blocks, carriers and cable condition before blaming the module.
Use an approved functional test and retain as-left diagnostic and acceptance evidence.
Alternative Names
Technical notes
Evidence scope: The Hardy official manual states the exact module role, channel count, measurement, backplane, calibration and environmental values used here.
Installation boundary: The exact installed carrier, terminals, cables and project configuration remain site-specific.
Technical reference: Hardy HI 1756-WS Weigh Scale Module User Guide
FAQ View All FAQ
-
How should 1756-WS be identified before replacement?Compare the complete 1756-WS marking, visible revision, installed position and the documented single-channel weigh scale module role. Do not approve a shortened family reference.
-
What evidence should be recorded before removing 1756-WS?Photograph the complete label, connectors, cable routes, status indications and host position for 1756-WS; retain the current Allen-Bradley ControlLogix chassis platform record.
-
How should the interfaces for 1756-WS be checked?Map every connector, terminal and cable used by 1756-WS to the as-found record, then verify keying, shielding and interface ownership before reconnection.
-
What configuration boundary matters when commissioning 1756-WS?Use the approved Allen-Bradley ControlLogix chassis platform configuration for 1756-WS. Physical fit alone does not establish electrical, firmware or project equivalence.
-
How can a suspected 1756-WS fault be separated from an external fault?Check host power, mating hardware, field wiring and the applicable signal or communication path before controlled substitution of 1756-WS.
-
What should be verified after installing 1756-WS?Confirm normal indications, interface continuity and the intended single-channel weigh scale module response for 1756-WS in an approved test state.
-
Can 1756-WS be replaced by a similar-looking unit?Appearance is not an equivalence criterion for 1756-WS; compare the complete order code, revision, connectors and installed configuration.
-
What handover record is appropriate after work on 1756-WS?Retain the offered and removed 1756-WS markings, connection photographs, configuration evidence, diagnostics, functional-test results and open exceptions.
Supporting new and legacy automation
-
Please try to be as accurate as possible with your search.
-
We can quote you on 1000s of specialist parts, even if they are not listed on our website.
-
We can't find any results for “”.
Related cases and sourcing guidance
View all case studiesYou May Also Like
Product Browsing History
-
Whatsapp: +86 18030235313
Send us a message. -
sales13@apterpower.com
Complete our online form. -
+86 18030235313
Speak to our team in your native language.