Match the complete marking
Provide the complete DS3800NGDC1A1A label, installed-position photographs and connected-component identities.
-
Check the offered item before ordering
Compare the offered DS3800NGDC1A1A hardware, interfaces and included items with the approved drawing.
Technical specifications for DS3800NGDC1A1A
-
Manufacturer:General Electric
-
Product Category:Gas Turbine Control
-
Spare Part Number:DS3800NGDC1A1A
-
Weight:0.3 kg
-
Tariff Code:8537101190
-
Product type:Ground Detector Module
-
Product family:DS3800 / Mark IV
-
Functional acronym:NGDC
-
Module function:Ground detection
-
System family:Mark IV Speedtronic
-
Board transistors:3
-
Integrated circuits:4
-
Test points:TP0 through TP5
-
Terminal hardware:Two-position block and five-position strip
-
Revision suffix:C1A1A
Information
- DS3800NGDC1A1A is the complete offered reference for a ground detector module in Mark IV Speedtronic protection hardware.
Identity-led replacement: The complete DS3800NGDC1A1A marking keeps revision, interface and fitted-position decisions tied to the actual unit.
Controlled return to service: Connector, terminal, setting and diagnostic evidence are checked before the affected function is released.
The verified technical rows distinguish exact-model identity from family-level system context. Dimensions and weight are shipping estimates supplied for this offered item; technical acceptance follows the installed drawing and manufacturer evidence.
Before exchange, record the fitted position, every connector or terminal identity, adjustable settings and the healthy operating baseline. After installation, prove the affected function under a controlled site procedure.
DS3800NGDC1A1A Technical Reference
Product-specific engineering reference covering verified identity, function, interfaces, inspection and acceptance information for DS3800NGDC1A1A.DS3800NGDC1A1A Installation & Verification Guide
Model-specific identity capture, controlled exchange, fault-isolation, commissioning and handover checks.
Application scope: Use DS3800NGDC1A1A only where the complete marking, hardware execution and installed interface match the approved design.
Exact-model service replacement
Replace the same DS3800NGDC1A1A execution after documenting the installed interface.System maintenance
Retain the Mark IV Speedtronic protection hardware relationship and approved drawing references.Controlled fault isolation
Separate board, wiring, power and companion-hardware causes before substitution.Commissioning evidence
Capture diagnostics and a functional test of the affected ground detector module path.
Photograph DS3800NGDC1A1A and all secondary labels before removal.
Record jumpers, switches, firmware, ranges or calibration references that apply.
Follow the approved isolation and electrostatic handling procedure.
Mark conductors, plugs, fibers or tubing by their installed identifiers.
Check contacts, terminals, guides, supports and protective earth.
Verify diagnostics and actual process or equipment response before handover.
Alternative Names
Technical notes
Evidence boundary: General Electric Mark IV service documentation and complete product marking
Exact-model rule: Do not infer interchangeability from a similar family code; match DS3800NGDC1A1A completely.
Acceptance record: Retain identity, interface, settings, diagnostics and functional proof.
FAQ View All FAQ
-
Which installed identity details must be recorded for DS3800NGDC1A1A?Record the full label, fitted position, connector or terminal map, and every adjustable setting before removal.
-
What interface check is most important before replacing DS3800NGDC1A1A?Compare the receiving hardware and every keyed, numbered or polarized connection with the approved drawing.
-
How should settings be controlled when servicing DS3800NGDC1A1A?Photograph and transcribe jumpers, switches, firmware or range selections that apply to this exact execution.
-
What should be inspected before fitting DS3800NGDC1A1A?Inspect contacts, terminal hardware, board supports, protective earth and nearby wiring for damage or contamination.
-
Which companion hardware must be verified with DS3800NGDC1A1A?Confirm the associated controller, terminal board, rack, power source or field device named by the installed design.
-
How should energization be managed after installing DS3800NGDC1A1A?Restore energy in the approved sequence, watch diagnostics, and stop if the expected healthy state is not obtained.
-
What functional proof adds technical value for DS3800NGDC1A1A?Exercise the affected signal, protection, power or communications path and retain before-and-after readings.
-
What handover record is required after commissioning DS3800NGDC1A1A?Keep the exact part marking, installed photographs, settings, test results, deviations and responsible approval.
Supporting new and legacy automation
-
Please try to be as accurate as possible with your search.
-
We can quote you on 1000s of specialist parts, even if they are not listed on our website.
-
We can't find any results for “”.
Related cases and sourcing guidance
View all case studies-
Receiving Inspection and Acceptance of Replacement Control ModulesRead case > -
24 Siemens Spare Parts Delivered to an Australian Waste Management FacilityRead case > -
Planning dispatch and following your shipmentRead case > -
GE IS420UCSBH4A: Confirm the Offered Controller and Release TermsRead case >
You May Also Like
Product Browsing History
-
DS3800NGDC1A1AProduct Details -
DS200UPSAG1AGDProduct Details -
DS200KLDBG1ABCProduct Details -
DS200IMCPG1CGCProduct Details -
IS230TNTRH1CProduct Details -
DS215SDCCG1AProduct Details -
DS200SDCIG1ABAProduct Details -
DS200SDCIG2ABAProduct Details -
IS400AEBMH1AJDProduct Details -
8115-DO-DC-01Product Details
-
Whatsapp: +86 18030235313
Send us a message. -
sales13@apterpower.com
Complete our online form. -
+86 18030235313
Speak to our team in your native language.