Match the complete marking
Compare DS200SDCIG1ABA with the installed board and applicable GE documentation.
-
Check the offered item before ordering
Request photos of DS200SDCIG1ABA; compare board marking, plugs, jumpers and included items with the installed unit.
Technical specifications for DS200SDCIG1ABA
-
Manufacturer:General Electric
-
Product Category:Gas Turbine Control
-
Spare Part Number:DS200SDCIG1ABA
-
Weight:0.96 kg
-
Tariff Code:8537101190
-
SDCI group:G1
-
Ac input:38 V ac ±10%
-
Logic output:+5 V dc at 4 A
-
Regulated positive output:+15 V dc at 0.4 A
-
Regulated negative output:-15 V dc at 0.4 A
-
External ±15 V capacity:0.25 A
-
Positive unregulated output:+24 V dc at 3 A
-
Negative unregulated output:-24 V dc at 1 A
-
External ±24 V capacity:0.5 A
-
Ac auxiliary output:115 V ac at 0.4 A
-
FU2 and FU3 rating:7 A, 2AG
-
Blown-fuse indicators:CR51 and CR55
-
Field-shunt VCO nominal frequency:250 kHz
-
Field-shunt VCO range:0–500 kHz
-
VCO isolation level:Up to 600 V
-
Firing-pulse oscillator:25 kHz at 10% duty cycle
-
Contactor-delay selection:JP2; approximately 100 ms in normal position
-
Revision string:ABA
-
Internal field-supply ceiling:10 A
-
Field fuses:FU5 and FU6
-
Field-fuse indicators:LT5 and LT6
Information
- DS200SDCIG1ABA has a defined dc power supply and instrumentation board role in the GE DC2000 drive-control system; selection depends on the complete board marking and installed execution.
Power boundary: Verify 38 V ac input and the published dc and 115 V ac outputs.
Instrumentation boundary: Preserve VCO, burden and firing-pulse paths before replacement.
Within the GE DC2000 drive-control system, evaluate this board together with its plugs, jumpers, connected power and feedback paths. Preserve the as-found interface map and revision evidence; a mechanically similar board is not automatically equivalent.
Commissioning should progress from identity and connection checks to controlled power-up, diagnostics and functional proof. Keep measured results, final status and open exceptions in the handover record.
-
GE DC2000 SDCI Original Instruction Excerpt
Original GE pages - PDF, 4 pages. SDCI power outputs, fuses, VCO circuits, field-supply boundary and jumper settings. -
DS200SDCIG1ABA Installation & Commissioning Guide
Apter Power engineering guide - PDF, 5 pages. Replacement sequence, commissioning checks, diagnostics and acceptance evidence.
Compatibility boundary: Match the complete group, revision, connectors and configured signal path before replacement.
-
Logic-power distribution
Provide regulated and unregulated control supplies for the DC2000 drive. -
Instrumentation conversion
Maintain field-shunt and armature-current VCO paths. -
Firing-pulse interface
Verify the 25 kHz, 10% duty-cycle SYOSC path from SDCC. -
Field-supply boundary
Confirm G1 internal or G2 external field-exciter execution before approval.
Check every token in DS200SDCIG1ABA against the offered board and approved record.
Follow the site procedure for dc bus, field supply, control power, stored energy and electrostatic handling.
Photograph and label every connector, wire jumper and hardware jumper before removal.
Archive the applicable GE DC2000 drive-control system settings and drawings before replacement.
Check connectors, ribbon cables, terminal boards and cable condition before attributing a fault to the board.
Use an approved controlled test and retain measured values, diagnostics and acceptance evidence.
Alternative Names
Technical notes
Pre-purchase checks: Match the offered DS200SDCIG1ABA nameplate, board group, revision string, connector execution and jumper arrangement with the installed board and approved drawings.
Installed-system compatibility: Verify the exact GE DC2000 drive-control system position, mating boards, power or signal paths and configuration settings. A family reference or similar appearance does not establish interchangeability.
Quotation confirmation: Confirm available quantity, estimated dispatch date, lead-time starting event, included items and documents in writing. Country of origin: USA. Condition: New, original product. Shipping: Swift global dispatch.
FAQ View All FAQ
-
How should DS200SDCIG1ABA be identified before a replacement is approved?Use the complete DS200SDCIG1ABA marking, board group and revision string. Compare the installed position and documented dc power supply and instrumentation board role before approval.
-
What evidence should be retained before removing DS200SDCIG1ABA?Photograph the complete marking, connector positions, jumper settings and status indications. Record the position in the GE DC2000 drive-control system.
-
How should the connectors for DS200SDCIG1ABA be checked during installation?Label each plug before removal, then restore every connection from the as-found record and the applicable GE manual. Never force a keyed connector.
-
What configuration boundary matters when commissioning DS200SDCIG1ABA?Use the exact board group, hardware execution and approved drive record. A similar board family or physical fit does not establish interchangeability.
-
How can a suspected DS200SDCIG1ABA fault be separated from wiring or carrier faults?Verify the documented supplies and reference signals first, inspect mating connectors and external wiring, then use a controlled substitution only after both signal paths are recorded.
-
What should be verified after fitting DS200SDCIG1ABA?Check normal host indications and the intended dc power supply and instrumentation board function under an approved controlled test. Retain measured values and diagnostics with the handover record.
-
Can DS200SDCIG1ABA be replaced by a similar-looking assembly?No direct equivalence is established by appearance. Compare the complete code, group, revision, connector execution and installed configuration.
-
What handover record is appropriate after work on DS200SDCIG1ABA?Retain offered and removed markings, connection photographs, jumper or configuration evidence, measured checks, functional-test results and unresolved exceptions.
Supporting new and legacy automation
-
Please try to be as accurate as possible with your search.
-
We can quote you on 1000s of specialist parts, even if they are not listed on our website.
-
We can't find any results for “”.
Related cases and sourcing guidance
View all case studiesYou May Also Like
Product Browsing History
-
Whatsapp: +86 18030235313
Send us a message. -
sales13@apterpower.com
Complete our online form. -
+86 18030235313
Speak to our team in your native language.