Match the complete marking
Include 8115-DO-DC-01 and every revision or approval marking visible on the item. Keep the exact reference on your enquiry and quotation. -
Check the offered item before ordering
Request available label and interface photos. Have your maintenance team compare the offered 8115-DO-DC-01 reference with the installed equipment and applicable General Electric documentation.
Technical specifications for 8115-DO-DC-01
-
Manufacturer:General Electric
-
Product Category:DCS Systems
-
Spare Part Number:8115-DO-DC-01
-
Weight:0.3 kg
-
Tariff Code:8537101190
-
Output channels:8
-
Load-voltage range:2 to 60 Vdc
-
Output isolation:Non-isolated
-
Continuous current per channel:1 A
-
Inrush per channel:4 A below 100 ms; 6 A below 20 ms
-
Module continuous-current total:6 A
-
Module inrush total:10 A below 100 ms; 18 A below 20 ms
-
ON-state voltage drop:0.25 V maximum
-
OFF-state leakage:1 mA maximum
-
Pulse duration range:2 ms to 130 s
-
Output response:1 ms maximum
-
Railbus current:45 mA typical; 70 mA maximum
-
Module key:B6
-
Published module width:42 mm
-
Published unit weight:200 g
-
General-purpose terminals:8604-FT-FU or 8602-FT-ST
-
Hazardous-area terminals:8611-FT-FU or 8610-FT-NA
Information
- The module switches eight non-isolated DC loads and supports discrete, momentary and continuous-pulse output behavior through the PAC8000 Railbus.
Module load boundary: 6 A continuous total; 10 A below 100 ms or 18 A below 20 ms for inrush
Control modes: Discrete, momentary or continuous-pulse operation with 2 ms to 130 s timing
Fail-safe behavior may hold the last value or drive a predefined state according to the stored PAC8000 configuration. Recover this behavior before connecting process loads.
Terminal-unit selection depends on the installation classification. Confirm B6 keying and whether the panel uses the general-purpose or hazardous-area terminal family.
-
General Electric 8115-DO-DC-01 technical reference
Eight-channel DC output architecture, channel/module current limits, timing modes, B6 keying and terminal-class boundary. -
General Electric 8115-DO-DC-01 engineering guide
Load audit, safe-state isolation, fallback recovery, pulse-duration checks and Railbus/process-feedback commissioning.
Platform applications: The uses below require the documented GE PAC8000 discrete-output station companion components and approved machine drawing.
-
Relay and solenoid switching
Drive 2-60 Vdc coils whose continuous and inrush demand remains within channel and module limits. -
Momentary command outputs
Use the 2 ms to 130 s timing range for documented start, reset or trip pulses. -
Fail-safe actuator states
Restore the predefined or last-value fallback required by the process risk assessment. -
PAC8000 DC load banks
Allocate simultaneous outputs so the shared field supply and 6 A module total are not exceeded.
Check each load and the simultaneous module total against the 20 ms and 100 ms limits.
Keep the field supply within 2-60 Vdc and confirm polarity before energizing.
Export initialization, fallback, pulse mode and duration for all used channels.
Use B6 keying and the terminal unit approved for the panel classification.
Isolate actuators or place equipment in a safe state before forcing outputs.
Command each used channel and record voltage drop, current and process feedback.
Alternative Names
Technical notes
Current audit: Record continuous and inrush current for each output plus the worst simultaneous module total.
Fail-safe proof: Remove the commanded data path under the approved test and confirm the configured fallback state.
Pulse proof: Measure momentary output duration on every channel using timed control.
FAQ View All FAQ
-
Why must total module current be calculated for 8115-DO-DC-01 even when each load is within its channel rating?The shared module limit can be exceeded by several acceptable channel loads; total the worst simultaneous continuous demand before enabling outputs.
-
How should inductive or lamp inrush be assessed on 8115-DO-DC-01?Measure or obtain each load inrush and duration, combine simultaneous events and compare both channel and module short-duration limits.
-
How should fail-safe behavior be proven on 8115-DO-DC-01?Place equipment in the approved test state, interrupt the commanded data path and confirm that each used output reaches its stored fallback or retained state.
-
What must be retained when 8115-DO-DC-01 uses momentary or continuous-pulse outputs?Save the mode and duration per channel, then measure actual output timing and process feedback after restoration.
-
Why are B6 keying and terminal classification important for 8115-DO-DC-01?They control mechanical placement and the approved field interface; verify both before assuming a nearby PAC8000 terminal is suitable.
-
How should unexpected actuator motion be prevented while installing 8115-DO-DC-01?Isolate loads or place equipment in a safe state, verify field-supply polarity and restore outputs one controlled channel at a time.
-
What should be checked if an 8115-DO-DC-01 channel commands ON but the actuator does not respond?Measure field supply, output voltage drop and load current, then compare terminal wiring, fusing, fail-safe state and process feedback.
-
Which results complete commissioning of 8115-DO-DC-01?Retain every used channel command, voltage/current, pulse timing, fallback response, actuator feedback and Railbus diagnostic result.
Supporting new and legacy automation
-
Please try to be as accurate as possible with your search.
-
We can quote you on 1000s of specialist parts, even if they are not listed on our website.
-
We can't find any results for “”.
Related cases and sourcing guidance
View all case studiesYou May Also Like
Product Browsing History
-
Whatsapp: +86 18030235313
Send us a message. -
sales13@apterpower.com
Complete our online form. -
+86 18030235313
Speak to our team in your native language.