8115-DO-DC-01

PAC8000 8-Channel DC Discrete Output Module
General Electric 8115-DO-DC-01 (1)
General Electric 8115-DO-DC-01 (2)
General Electric 8115-DO-DC-01 (3)
General Electric 8115-DO-DC-01 (1)
General Electric 8115-DO-DC-01 (2)
General Electric 8115-DO-DC-01 (3)
Product image is representative; revision or series may vary. Contact us to request a specific version.

Product Describe:

8115-DO-DC-01 is an eight-channel, 2-60 Vdc PAC8000 discrete output module for switching relays, solenoids and other DC loads. Its shared field supply and current limits must be checked against both steady-state and inrush demand.
  • Manufacturer part number
    8115-DO-DC-01
  • Shipping
    Swift global dispatch
  • Condition
    New, original product
  • Shipping size (est.)
    10.6cm x 4.2cm x 11cm
  • Country of Origin
    USA
Get a quick price for 8115-DO-DC-01
E-mail *
Mobile
Company
Content *
Quantity *
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)
For more information on how your data is processed and stored by Apterpower please read our privacy policy

What happens after you enquire

  • 0

    Review your reference

    Send the 8115-DO-DC-01 label, B6 slot and terminal photographs, field-supply details and the eight-channel load/fail-safe schedule.
  • 1

    Confirm the offer

    Confirm terminal class, field-supply range, channel and module loading, pulse modes and fallback behavior.
  • 2

    Arrange dispatch

    Confirm quantity and keep the approved load calculation and safe-state record with the 8115-DO-DC-01 delivery.
  • Match the complete marking

    Include 8115-DO-DC-01 and every revision or approval marking visible on the item. Keep the exact reference on your enquiry and quotation.
  • Check the offered item before ordering

    Request available label and interface photos. Have your maintenance team compare the offered 8115-DO-DC-01 reference with the installed equipment and applicable General Electric documentation.

Technical specifications for 8115-DO-DC-01

  • Manufacturer:
    General Electric
  • Product Category:
    DCS Systems
  • Spare Part Number:
    8115-DO-DC-01
  • Weight:
    0.3 kg
  • Tariff Code:
    8537101190
  • Output channels:
    8
  • Load-voltage range:
    2 to 60 Vdc
  • Output isolation:
    Non-isolated
  • Continuous current per channel:
    1 A
  • Inrush per channel:
    4 A below 100 ms; 6 A below 20 ms
  • Module continuous-current total:
    6 A
  • Module inrush total:
    10 A below 100 ms; 18 A below 20 ms
  • ON-state voltage drop:
    0.25 V maximum
  • OFF-state leakage:
    1 mA maximum
  • Pulse duration range:
    2 ms to 130 s
  • Output response:
    1 ms maximum
  • Railbus current:
    45 mA typical; 70 mA maximum
  • Module key:
    B6
  • Published module width:
    42 mm
  • Published unit weight:
    200 g
  • General-purpose terminals:
    8604-FT-FU or 8602-FT-ST
  • Hazardous-area terminals:
    8611-FT-FU or 8610-FT-NA

Information

Overview Downloads Applications / Compatibility Product Precautions
  • The module switches eight non-isolated DC loads and supports discrete, momentary and continuous-pulse output behavior through the PAC8000 Railbus.
Output capability: Eight 2-60 Vdc channels rated 1 A continuous each with defined short inrush limits
Module load boundary: 6 A continuous total; 10 A below 100 ms or 18 A below 20 ms for inrush
Control modes: Discrete, momentary or continuous-pulse operation with 2 ms to 130 s timing
The channel rating does not override the 6 A continuous module limit. Sum all load currents and evaluate simultaneous coil or lamp inrush before assigning the eight outputs.

Fail-safe behavior may hold the last value or drive a predefined state according to the stored PAC8000 configuration. Recover this behavior before connecting process loads.

Terminal-unit selection depends on the installation classification. Confirm B6 keying and whether the panel uses the general-purpose or hazardous-area terminal family.
Controller platform reference: GE PAC8000 discrete-output station. With actuators placed safe, command every used channel and record load voltage, current, timing, feedback and module diagnostics.
Use the 8115-DO-DC-01 reference to define load, inrush and pulse boundaries; use the field guide to restore fail-safe states, terminal selection and actuator acceptance.
The reference defines output capability; the guide proves that each connected actuator behaves safely under the restored configuration.
Return 8115-DO-DC-01 to service only after B6 slot identity, field-supply polarity, simultaneous inrush and every configured fail-safe state are controlled.
Calculate inrush

Check each load and the simultaneous module total against the 20 ms and 100 ms limits.

Verify load voltage

Keep the field supply within 2-60 Vdc and confirm polarity before energizing.

Recover fail-safe states

Export initialization, fallback, pulse mode and duration for all used channels.

Match the terminal family

Use B6 keying and the terminal unit approved for the panel classification.

Control unexpected motion

Isolate actuators or place equipment in a safe state before forcing outputs.

Prove all loads

Command each used channel and record voltage drop, current and process feedback.

Alternative Names

General Electric 8115-DO-DC-01 PAC8000 8-Channel DC Discrete Output Module GE PAC8000 Remote I/O discrete output modules 8115-DO-DC-01

Technical notes

Current audit: Record continuous and inrush current for each output plus the worst simultaneous module total.

Fail-safe proof: Remove the commanded data path under the approved test and confirm the configured fallback state.

Pulse proof: Measure momentary output duration on every channel using timed control.

FAQ View All FAQ

  • Why must total module current be calculated for 8115-DO-DC-01 even when each load is within its channel rating?
    The shared module limit can be exceeded by several acceptable channel loads; total the worst simultaneous continuous demand before enabling outputs.
  • How should inductive or lamp inrush be assessed on 8115-DO-DC-01?
    Measure or obtain each load inrush and duration, combine simultaneous events and compare both channel and module short-duration limits.
  • How should fail-safe behavior be proven on 8115-DO-DC-01?
    Place equipment in the approved test state, interrupt the commanded data path and confirm that each used output reaches its stored fallback or retained state.
  • What must be retained when 8115-DO-DC-01 uses momentary or continuous-pulse outputs?
    Save the mode and duration per channel, then measure actual output timing and process feedback after restoration.
  • Why are B6 keying and terminal classification important for 8115-DO-DC-01?
    They control mechanical placement and the approved field interface; verify both before assuming a nearby PAC8000 terminal is suitable.
  • How should unexpected actuator motion be prevented while installing 8115-DO-DC-01?
    Isolate loads or place equipment in a safe state, verify field-supply polarity and restore outputs one controlled channel at a time.
  • What should be checked if an 8115-DO-DC-01 channel commands ON but the actuator does not respond?
    Measure field supply, output voltage drop and load current, then compare terminal wiring, fusing, fail-safe state and process feedback.
  • Which results complete commissioning of 8115-DO-DC-01?
    Retain every used channel command, voltage/current, pulse timing, fallback response, actuator feedback and Railbus diagnostic result.
Manufacturers

Product Browsing History

Revisit the products you recently viewed on Apter Power.
SPEAK TO OUR TEAM
Let’s find the right solution for you.
Send us the part number, quantity and delivery destination. Our team will help confirm availability and lead time.
  • Whatsapp: +86 18030235313

    Send us a message.
  • sales13@apterpower.com

    Complete our online form.
  • +86 18030235313

    Speak to our team in your native language.