General Electric DS200SDCIG2ABA is identified as a dc power supply and instrumentation board for the GE DC2000 drive-control system. Match the complete marking, board group and installed interface arrangement before replacement.
  • Manufacturer part number
    DS200SDCIG2ABA
  • Shipping
    Swift global dispatch
  • Condition
    New, original product
  • Shipping size (est.)
    28cm × 21.2cm × 4cm
  • Country of Origin
    USA
Get a quick price for DS200SDCIG2ABA
E-mail *
Mobile
Company
Content *
Quantity *
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)
For more information on how your data is processed and stored by Apterpower please read our privacy policy

What happens after you enquire

  • 0

    Review your reference

    Send the complete DS200SDCIG2ABA marking, required quantity and installed drive context.

  • 1

    Confirm the offer

    Review the offered identity, condition, included items and delivery details.

  • 2

    Arrange dispatch

    Confirm the accepted quantity and destination in the quotation.

  • Match the complete marking

    Compare DS200SDCIG2ABA with the installed board and applicable GE documentation.

  • Check the offered item before ordering

    Request photos of DS200SDCIG2ABA; compare board marking, plugs, jumpers and included items with the installed unit.

Technical specifications for DS200SDCIG2ABA

  • Manufacturer:
    General Electric
  • Product Category:
    Gas Turbine Control
  • Spare Part Number:
    DS200SDCIG2ABA
  • Weight:
    0.64 kg
  • Tariff Code:
    8537101190
  • SDCI group:
    G2
  • Ac input:
    38 V ac ±10%
  • Logic output:
    +5 V dc at 4 A
  • Regulated positive output:
    +15 V dc at 0.4 A
  • Regulated negative output:
    -15 V dc at 0.4 A
  • External ±15 V capacity:
    0.25 A
  • Positive unregulated output:
    +24 V dc at 3 A
  • Negative unregulated output:
    -24 V dc at 1 A
  • External ±24 V capacity:
    0.5 A
  • Ac auxiliary output:
    115 V ac at 0.4 A
  • FU2 and FU3 rating:
    7 A, 2AG
  • Blown-fuse indicators:
    CR51 and CR55
  • Field-shunt VCO nominal frequency:
    250 kHz
  • Field-shunt VCO range:
    0–500 kHz
  • VCO isolation level:
    Up to 600 V
  • Firing-pulse oscillator:
    25 kHz at 10% duty cycle
  • Contactor-delay selection:
    JP2; approximately 100 ms in normal position
  • Revision string:
    ABA
  • External field-exciter boundary:
    More than 10 A
  • Internal field circuit:
    Not fitted for G2

Information

Overview Downloads Applications / Compatibility Product Precautions
  • DS200SDCIG2ABA has a defined dc power supply and instrumentation board role in the GE DC2000 drive-control system; selection depends on the complete board marking and installed execution.
Group boundary: G2 determines the field-supply execution.
Power boundary: Verify 38 V ac input and the published dc and 115 V ac outputs.
Instrumentation boundary: Preserve VCO, burden and firing-pulse paths before replacement.
The complete DS200SDCIG2ABA marking identifies the offered dc power supply and instrumentation board. Record the removed board, host position and connected hardware so the comparison uses the actual installed boundary rather than a shortened family name.

Within the GE DC2000 drive-control system, evaluate this board together with its plugs, jumpers, connected power and feedback paths. Preserve the as-found interface map and revision evidence; a mechanically similar board is not automatically equivalent.

Commissioning should progress from identity and connection checks to controlled power-up, diagnostics and functional proof. Keep measured results, final status and open exceptions in the handover record.
Controller platform reference: GE DC2000 drive-control system. Use the applicable GE instruction and approved drive drawings for installation and commissioning.
The first document provides the applicable GE technical reference for DS200SDCIG2ABA. The separate Apter Power field guide covers installation checks, commissioning, diagnostics and handover.
Use the applicable General Electric documentation and site-approved installation procedure for DS200SDCIG2ABA.
Prepare General Electric DS200SDCIG2ABA using the applicable installation instructions and site isolation procedure.
Verify the complete identity

Check every token in DS200SDCIG2ABA against the offered board and approved record.

Isolate all connected energy

Follow the site procedure for dc bus, field supply, control power, stored energy and electrostatic handling.

Record plugs and jumpers

Photograph and label every connector, wire jumper and hardware jumper before removal.

Preserve drive configuration

Archive the applicable GE DC2000 drive-control system settings and drawings before replacement.

Inspect mating hardware

Check connectors, ribbon cables, terminal boards and cable condition before attributing a fault to the board.

Prove the intended function

Use an approved controlled test and retain measured values, diagnostics and acceptance evidence.

Alternative Names

GE DS200 SDCI G2 ABA General Electric G2 DC Power Supply Instrumentation Board

Technical notes

Pre-purchase checks: Match the offered DS200SDCIG2ABA nameplate, board group, revision string, connector execution and jumper arrangement with the installed board and approved drawings.

Installed-system compatibility: Verify the exact GE DC2000 drive-control system position, mating boards, power or signal paths and configuration settings. A family reference or similar appearance does not establish interchangeability.

Quotation confirmation: Confirm available quantity, estimated dispatch date, lead-time starting event, included items and documents in writing.

FAQ View All FAQ

  • How should DS200SDCIG2ABA be identified before a replacement is approved?
    Use the complete DS200SDCIG2ABA marking, board group and revision string. Compare the installed position and documented dc power supply and instrumentation board role before approval.
  • What evidence should be retained before removing DS200SDCIG2ABA?
    Photograph the complete marking, connector positions, jumper settings and status indications. Record the position in the GE DC2000 drive-control system.
  • How should the connectors for DS200SDCIG2ABA be checked during installation?
    Label each plug before removal, then restore every connection from the as-found record and the applicable GE manual. Never force a keyed connector.
  • What configuration boundary matters when commissioning DS200SDCIG2ABA?
    Use the exact board group, hardware execution and approved drive record. A similar board family or physical fit does not establish interchangeability.
  • How can a suspected DS200SDCIG2ABA fault be separated from wiring or carrier faults?
    Verify the documented supplies and reference signals first, inspect mating connectors and external wiring, then use a controlled substitution only after both signal paths are recorded.
  • What should be verified after fitting DS200SDCIG2ABA?
    Check normal host indications and the intended dc power supply and instrumentation board function under an approved controlled test. Retain measured values and diagnostics with the handover record.
  • Can DS200SDCIG2ABA be replaced by a similar-looking assembly?
    No direct equivalence is established by appearance. Compare the complete code, group, revision, connector execution and installed configuration.
  • What handover record is appropriate after work on DS200SDCIG2ABA?
    Retain offered and removed markings, connection photographs, jumper or configuration evidence, measured checks, functional-test results and unresolved exceptions.
SPEAK TO OUR TEAM
Let’s find the right solution for you.
Send us the part number, quantity and delivery destination. Our team will help confirm availability and lead time.
  • Whatsapp: +86 18030235313

    Send us a message.
  • sales13@apterpower.com

    Complete our online form.
  • +86 18030235313

    Speak to our team in your native language.