Technical specifications for DS215SDCCG1A
-
Manufacturer:General Electric
-
Product Category:Gas Turbine Control
-
Spare Part Number:DS215SDCCG1A
-
Weight:0.54 kg
-
Tariff Code:8537101190
-
Board group:G1
-
Main processors:3
-
Drive Control Processor:80C186 at U1
-
Motor Control Processor:80C196 at U21
-
Co-motor Processor:TMS320C25 at U35
-
Documented plug connectors:8
-
Unused connector:9PL
-
Meter connector:11PL
-
Diagnostic LEDs:10
-
Slow fault-code range:1–399
-
Fast fault-code range:400–1023
-
DCP timing test point:720 Hz
-
Slow-background test point:90 Hz
-
MCP oscillator test point:8 MHz
-
Regulated logic test point:+5 V ±5%
-
Analog supply test points:+15 V and -15 V, each ±5%
-
Control-input maximum:±24 V
-
Control-input impedance:27 kΩ
-
Reset noise filter:20 ms
-
Analog output no-load span:±10 V
-
Analog output loaded span:±8 V at 10 mA
-
Analog output series resistance:200 Ω
-
Feedback VCO gain jumper:JP7; 6:1
-
EEPROM write-protect jumper:JP1
-
Signal-mode jumper:JP8; bipolar or absolute
-
Installed memory devices:5
-
EPROM devices:4: U11, U12, U22 and U23
-
EEPROM devices:1: U9
Information
- DS215SDCCG1A has a defined drive control card role in the GE AC2000, DC2000 and EX2000 drive-control systems; selection depends on the complete board marking and installed execution.
Diagnostic boundary: 10 LEDs distinguish slow 1–399 and fast 400–1023 fault-code ranges.
Memory boundary: DS215 carries four EPROMs plus one EEPROM.
Within the GE AC2000, DC2000 and EX2000 drive-control systems, evaluate this board together with its plugs, jumpers, connected power and feedback paths. Preserve the as-found interface map and revision evidence; a mechanically similar board is not automatically equivalent.
Commissioning should progress from identity and connection checks to controlled power-up, diagnostics and functional proof. Keep measured results, final status and open exceptions in the handover record.
-
GE Drive Control Card Instruction Manual GEI-100029C
Original GE manual - PDF, 20 pages. G1 processors, connectors, diagnostics, test points, memory and jumper functions. -
DS215SDCCG1A Installation & Commissioning Guide
Apter Power engineering guide - PDF, 5 pages. Replacement sequence, commissioning checks, diagnostics and acceptance evidence.
Compatibility boundary: Match the complete group, revision, connectors and configured signal path before replacement.
-
Drive control processing
Use DCP, MCP and CMP diagnostics together when isolating a fault. -
Connector restoration
Restore all documented plugs and keep unused 9PL unassigned. -
Diagnostic interpretation
Record the 10-LED sequence and distinguish the two published fault-code ranges. -
Memory execution
Confirm the DS215 populated memory execution before approval.
Check every token in DS215SDCCG1A against the offered board and approved record.
Follow the site procedure for dc bus, field supply, control power, stored energy and electrostatic handling.
Photograph and label every connector, wire jumper and hardware jumper before removal.
Archive the applicable GE AC2000, DC2000 and EX2000 drive-control systems settings and drawings before replacement.
Check connectors, ribbon cables, terminal boards and cable condition before attributing a fault to the board.
Use an approved controlled test and retain measured values, diagnostics and acceptance evidence.
Alternative Names
Technical notes
Pre-purchase checks: Match the offered DS215SDCCG1A nameplate, board group, revision string, connector execution and jumper arrangement with the installed board and approved drawings.
Installed-system compatibility: Verify the exact GE AC2000, DC2000 and EX2000 drive-control systems position, mating boards, power or signal paths and configuration settings. A family reference or similar appearance does not establish interchangeability.
Quotation confirmation: Confirm available quantity, estimated dispatch date, lead-time starting event, included items and documents in writing.
FAQ View All FAQ
-
How should DS215SDCCG1A be identified before a replacement is approved?Use the complete DS215SDCCG1A marking, board group and revision string. Compare the installed position and documented drive control card role before approval.
-
What evidence should be retained before removing DS215SDCCG1A?Photograph the complete marking, connector positions, jumper settings and status indications. Record the position in the GE AC2000, DC2000 and EX2000 drive-control systems.
-
How should the connectors for DS215SDCCG1A be checked during installation?Label each plug before removal, then restore every connection from the as-found record and the applicable GE manual. Never force a keyed connector.
-
What configuration boundary matters when commissioning DS215SDCCG1A?Use the exact board group, hardware execution and approved drive record. A similar board family or physical fit does not establish interchangeability.
-
How can a suspected DS215SDCCG1A fault be separated from wiring or carrier faults?Verify the documented supplies and reference signals first, inspect mating connectors and external wiring, then use a controlled substitution only after both signal paths are recorded.
-
What should be verified after fitting DS215SDCCG1A?Check normal host indications and the intended drive control card function under an approved controlled test. Retain measured values and diagnostics with the handover record.
-
Can DS215SDCCG1A be replaced by a similar-looking assembly?No direct equivalence is established by appearance. Compare the complete code, group, revision, connector execution and installed configuration.
-
What handover record is appropriate after work on DS215SDCCG1A?Retain offered and removed markings, connection photographs, jumper or configuration evidence, measured checks, functional-test results and unresolved exceptions.
Supporting new and legacy automation
-
Please try to be as accurate as possible with your search.
-
We can quote you on 1000s of specialist parts, even if they are not listed on our website.
-
We can't find any results for “”.
Related cases and sourcing guidance
View all case studiesYou May Also Like
Product Browsing History
-
Whatsapp: +86 18030235313
Send us a message. -
sales13@apterpower.com
Complete our online form. -
+86 18030235313
Speak to our team in your native language.