Match the complete marking
Compare every token in IS230TNTRH1C with the installed label and the applicable manufacturer document.
-
Verify the assembly boundary
Confirm the terminal board, I/O pack, connector, carrier or matched-system components that belong with IS230TNTRH1C.
Technical specifications for IS230TNTRH1C
-
Manufacturer:General Electric
-
Product Category:Gas Turbine Control
-
Spare Part Number:IS230TNTRH1C
-
Weight:0.65 kg
-
Tariff Code:8537101190
-
Product type:TMR Primary Turbine Protection Module
-
Control platform:GE Mark VIe
-
GE notice mapping:No-price-impact catalog number corresponding to IS230TTURH1C
-
I/O pack redundancy:TMR
-
I/O pack family:PTUR
-
I/O pack quantity:3
-
Included terminal board:IS200TTURH1C
-
Functional description:Primary Turbine Protection
-
Mounting:DIN-rail mount
-
Mark VIe I/O-pack Ethernet ports:2 per I/O pack; platform architecture
-
IONet link:100 MB full-duplex point-to-point; platform architecture
-
I/O-pack internal elements:Power supply, local processor and data-acquisition board; platform architecture
Information
- IS230TNTRH1C has a defined tmr primary turbine protection module role in the GE Mark VIe control platform; approval depends on the complete catalog number and installed assembly boundary.
Redundancy: TMR execution for the primary turbine protection path.
Installation format: DIN-rail Mark VIe module; match the complete IS230TNTRH1C catalog number.
The associated component reference is IS230TTURH1C. That mapping is useful for identity review, but the offered item remains IS230TNTRH1C; the catalog numbers must not be shortened or interchanged when the installed module is approved.
At platform level, each Mark VIe I/O pack contains two Ethernet ports, a local processor, a power supply and a data-acquisition board. Commissioning IS230TNTRH1C therefore requires both terminal-side verification and confirmation of the IONet and controller diagnostic path. All three PTUR paths and the protection test boundary must be verified together.
IS230TNTRH1C Applicable Manufacturer Document
Verified manufacturer material - PDF. Exact catalog mapping, applicable hardware composition and technical boundary.IS230TNTRH1C Installation & Commissioning Guide
Apter Power engineering guide - PDF, 5 pages. Identity checks, interface restoration, diagnostics, acceptance and handover.
Compatibility boundary: Match the complete IS230TNTRH1C marking, mating hardware and installed configuration before replacement.
Mark VIe I/O replacement
Replace the documented DIN-rail module only after matching the complete catalog number and terminal-board execution.Planned outage maintenance
Capture the installed I/O mapping, pack positions and field wiring before disturbing the assembly.Controlled commissioning
Restore the approved Mark VIe configuration and prove the exact input, output or protection path.Spare qualification
Retain catalog number, redundancy, included terminal board and I/O-pack quantity with the spare record.
Check every letter and number against the offered label and the approved Mark VIe hardware record.
Apply the site procedure before touching terminal-board wiring, I/O packs or DIN-rail hardware.
Photograph IONet ports, pack positions, terminal wiring, shields and connector orientation before removal.
Archive the controller database, diagnostics and I/O mapping that identify the installed signal path.
Check terminal-board connectors, I/O-pack seating, field terminals and Ethernet cabling before replacing the assembly.
Use an approved signal or protection test and retain as-left diagnostics with the maintenance record.
Alternative Names
Technical notes
Identity control: Use IS230TNTRH1C, not IS230TTURH1C, as the offered catalog number and compare the complete label before installation.
Hardware relationship: The documented assembly uses 3 PTUR I/O packs with IS200TTURH1C; confirm these parts against the available unit.
Commissioning boundary: Restore the approved primary turbine protection mapping, IONet path and controller diagnostics before returning the channel to service.
FAQ View All FAQ
-
How should IS230TNTRH1C be identified before replacement?Match the full IS230TNTRH1C label, the tmr execution, PTUR pack count and IS200TTURH1C terminal board against the installed Mark VIe record.
-
What installed interfaces must be checked for IS230TNTRH1C?Verify the IS200TTURH1C terminal board, all 3 PTUR pack positions, Ethernet connections and field terminals used by IS230TNTRH1C.
-
Which configuration values must be preserved before removing IS230TNTRH1C?Archive the Mark VIe I/O mapping, controller diagnostics and the channel assignments associated with IS230TNTRH1C.
-
How should the field wiring for IS230TNTRH1C be verified?Trace every used terminal on IS200TTURH1C to the approved field drawing before reconnecting IS230TNTRH1C.
-
What should be checked before energizing IS230TNTRH1C?Confirm pack seating, terminal torque, shield handling, IONet connection and the approved tmr architecture for IS230TNTRH1C.
-
How can a suspected IS230TNTRH1C fault be separated from an external fault?Check terminal-board wiring, pack power, IONet status and controller diagnostics before controlled substitution of IS230TNTRH1C.
-
What proves that IS230TNTRH1C is operating correctly after installation?A controlled primary turbine protection test must produce the expected field response and clean Mark VIe diagnostics for IS230TNTRH1C.
-
What should be retained in the handover record for IS230TNTRH1C?Retain the IS230TNTRH1C label, PTUR/IS200TTURH1C composition, connection photographs, diagnostics and controlled-test result.
Supporting new and legacy automation
-
Please try to be as accurate as possible with your search.
-
We can quote you on 1000s of specialist parts, even if they are not listed on our website.
-
We can't find any results for “”.
Related cases and sourcing guidance
View all case studiesYou May Also Like
Product Browsing History
-
Whatsapp: +86 18030235313
Send us a message. -
sales13@apterpower.com
Complete our online form. -
+86 18030235313
Speak to our team in your native language.