Get a quick price for DS200TCQBG1BCB DS215TCQBG1BZZ01A
For more information on how your data is processed and stored by Apterpower please read our privacy policy
-
Match the complete marking
Include DS200TCQBG1BCB DS215TCQBG1BZZ01A and every revision or approval marking visible on the item. Keep the exact reference on your enquiry and quotation. -
Check the offered item before ordering
Request available label and interface photos. Have your maintenance team compare the offered DS200TCQBG1BCB DS215TCQBG1BZZ01A reference with the installed equipment and applicable GE documentation.
Technical specifications for DS200TCQBG1BCB DS215TCQBG1BZZ01A
-
Manufacturer:General Electric
-
Product Category:Gas Turbine Control
-
Spare Part Number:DS200TCQBG1BCB DS215TCQBG1BZZ01A
-
Weight:0.66 kg
-
Proximity-vibration configuration channels:18
-
Position configuration channels:10
-
Keyphasor configuration channels:2
-
Channels selectable for accelerometer use:3
Information
Overview
Downloads
Applications / Compatibility
Product Precautions
- The first three vibration channels can change sensor interpretation only when software definitions and the physical TCQB jumpers agree.
Sensor-mode coordination: Hardware jumpers and configuration are checked as one decision.
Shaft-aware vibration analysis: Channel assignment retains its HP, IP or LP shaft relationship.
Distinct signal duties: Vibration, position and keyphasor channels use different engineering interpretation.
Shaft-aware vibration analysis: Channel assignment retains its HP, IP or LP shaft relationship.
Distinct signal duties: Vibration, position and keyphasor channels use different engineering interpretation.
The combined DS200TCQBG1BCB and DS215TCQBG1BZZ01A identity is retained for the offered TCQB assembly. Its Mark V configuration separates proximity-vibration channels, position inputs and keyphasor inputs. An input with a plausible voltage is not accepted until its assigned signal duty and scale are correct.
PRX01 through PRX03 can be configured for proximity transducers or accelerometer-derived signals. Changing the software field alone is insufficient: the TCQB hardware jumpers must also match. Where accelerometers use those inputs, the proximity shaft-location assignments for the affected channels are set as not used under the documented configuration method.
For accelerometer processing, HP/IP/LP maximum-rpm scaling fields use a power of two above the highest expected scaled shaft speed. This is not the highest pulse frequency from a speed pickup, and example screen values are not universal defaults. Preserve the installed sensor mode, shaft association and approved configuration before comparing post-exchange vibration behavior.
PRX01 through PRX03 can be configured for proximity transducers or accelerometer-derived signals. Changing the software field alone is insufficient: the TCQB hardware jumpers must also match. Where accelerometers use those inputs, the proximity shaft-location assignments for the affected channels are set as not used under the documented configuration method.
For accelerometer processing, HP/IP/LP maximum-rpm scaling fields use a power of two above the highest expected scaled shaft speed. This is not the highest pulse frequency from a speed pickup, and example screen values are not universal defaults. Preserve the installed sensor mode, shaft association and approved configuration before comparing post-exchange vibration behavior.
Controller platform reference: Mark V extended analog I/O. Match the installed configuration.
For DS200TCQBG1BCB DS215TCQBG1BZZ01A, the Apter Power technical reference summarizes verified manufacturer data. The field guide develops sensor-mode, shaft-assignment and scaling acceptance.
DS200TCQBG1BCB DS215TCQBG1BZZ01A Technical Reference
Apter Power technical reference with manufacturer-based values and exact application boundaries. PDF · 1 pages · 90.9 KB.DS200TCQBG1BCB DS215TCQBG1BZZ01A Installation & Commissioning Guide
Sensor-Mode, Shaft-Assignment and Scaling Acceptance. Reconcile physical jumpers with channel purpose before comparing the returned vibration indication. PDF · 2 pages · 93.6 KB.
The technical reference is an Apter Power summary of the documented product data. The separate installation guide supports field verification for DS200TCQBG1BCB DS215TCQBG1BZZ01A.
System and supply context: For the documented TCQB extended analog/vibration configuration in the actual Mark V installation.
Application scope: Sensor type, jumper position, shaft assignment and engineering scale must agree; common assembly markings do not prove the delivered application configuration.
Application scope: Sensor type, jumper position, shaft assignment and engineering scale must agree; common assembly markings do not prove the delivered application configuration.
Proximity vibration service
Retain the correct transducer sensitivity and shaft association for the assigned vibration channel.Accelerometer-mode review
Coordinate the first-three-channel hardware jumpers and software device-type decision.Position interpretation
Keep position offset and sensitivity separate from peak-to-peak vibration scaling.Shaft-scaling acceptance
Compare actual HP/IP/LP speed interpretation with the approved accelerometer-processing setup.
Prepare GE DS200TCQBG1BCB DS215TCQBG1BZZ01A for its configured installation using these product-specific checks.
Keep the complete order pair
Retain BCB and the DS215 assembly marking.
Record device mode
Identify proximity or accelerometer use before removing the card.
Compare actual jumpers
Software selection alone does not prove electrical mode.
Preserve shaft assignments
Do not reuse a neighboring turbine’s HP/IP/LP values.
Separate signal scales
Position offset and vibration amplitude are different engineering quantities.
Prove the changed channel
Compare diagnostics and controlled response after restoring the accepted configuration.
Alternative Names
GE DS200TCQBG1BCB DS215TCQBG1BZZ01A
Technical notes
Mode boundary: The first-three-channel accelerometer option requires matching hardware and software.
Scaling boundary: Power-of-two rpm scaling uses expected scaled shaft speed, not pickup pulse frequency.
Identity boundary: The offered DS200/DS215 markings do not establish an undocumented EPROM set or revision interchange.
FAQ View All FAQ
-
Why is a software device-type change alone insufficient for DS200TCQBG1BCB DS215TCQBG1BZZ01A?The first-three-channel proximity/accelerometer choice also requires the physical TCQB jumpers to agree. Compare both before applying or interpreting the signal.
-
What happens to proximity shaft assignments when DS200TCQBG1BCB DS215TCQBG1BZZ01A uses accelerometers on the first channels?Follow the documented not-used assignment for the affected proximity entries and retain the accelerometer configuration. Do not leave conflicting signal interpretations active.
-
Why must the shaft association be checked before adjusting vibration scaling on DS200TCQBG1BCB DS215TCQBG1BZZ01A?The TCQB algorithm uses the selected HP, IP or LP shaft speed to determine the vibration sampling frequency; the manual describes sampling at eight times the fundamental to obtain first- and second-order components. Check the assigned shaft source before correcting a spectral symptom by changing transducer sensitivity.
-
Can speed-pickup pulse frequency be entered as the rpm scaling basis for DS200TCQBG1BCB DS215TCQBG1BZZ01A?Those are different quantities. Use the scaled shaft-speed basis specified for the accelerometer-processing fields.
-
Why can a plausible voltage still be wrongly interpreted by DS200TCQBG1BCB DS215TCQBG1BZZ01A?The assigned duty may be vibration, position or keyphasor, with different scales and offsets. Check channel role and configuration along with the electrical reading.
-
Should position offsets be copied into vibration scaling on DS200TCQBG1BCB DS215TCQBG1BZZ01A?No. Position and peak-to-peak vibration use distinct configuration fields. Retain each signal’s engineering purpose and approved values.
-
How is an unused proximity input prevented from raising inappropriate diagnostics on DS200TCQBG1BCB DS215TCQBG1BZZ01A?The TCQB configuration instructions use sensitivity 0 to disable diagnostics for an unused input. First establish that the channel is genuinely unused in the accepted configuration; do not suppress a failed active measurement by zeroing sensitivity.
-
Why must LVDT/LVDR endpoints be verified separately on DS200TCQBG1BCB DS215TCQBG1BZZ01A?The TCQB minimum and maximum voltage entries represent 0% and 100% stroke for the applicable input. Confirm the actual calibrated endpoints and direction; the example voltages in a configuration screen are not universal field settings or proximity-probe gap limits.
Manufacturers
Supporting new and legacy automation
Whether you're maintaining existing equipment or sourcing parts for current systems, we provide fast, dependable supply you can rely on.
-
Please try to be as accurate as possible with your search.
-
We can quote you on 1000s of specialist parts, even if they are not listed on our website.
-
We can't find any results for “”.
PRODUCTS IN SEARCH PAGE ()
50+ account managers available now
Related reading
Related cases and sourcing guidance
View all case studies
Manufacturers
You May Also Like
Explore related automation components available through Apter Power.
Manufacturers
Product Browsing History
Revisit the products you recently viewed on Apter Power.
-
DS200TCQBG1BCB DS215TCQBG1BZZ01AProduct Details -
DS200TCDAG1BFD DS215TCDAG1BZZ01AProduct Details -
IS200TSVCH2AJEProduct Details -
IS200EPSMG1ADCProduct Details -
DS200TBPAG1ACCProduct Details -
IS200TRLYH1BHHProduct Details -
IS200VRTDH1DACProduct Details -
IS200EPSMG1AECProduct Details -
IS200TVIBH2BCCProduct Details -
IS200EDCFG1AEDProduct Details
SPEAK TO OUR TEAM
Let’s find the right solution for you.
Send us the part number, quantity and delivery destination. Our team will help confirm availability and lead time.
-
Whatsapp: +86 18030235313
Send us a message. -
sales13@apterpower.com
Complete our online form. -
+86 18030235313
Speak to our team in your native language.