Match the complete marking
Include DS200DDTBG2ABB and any revision or assembly number visible on the item. Keep the exact reference on your enquiry and quotation.
-
Check the offered item before ordering
Request current label, board and connector photos of DS200DDTBG2ABB. Compare the offered reference and host configuration with the installed equipment before approval.
Technical specifications for DS200DDTBG2ABB
-
Manufacturer:General Electric
-
Product Category:General Automation
-
Spare Part Number:DS200DDTBG2ABB
-
Weight:0.8 kg
-
Tariff Code:8537101190
-
Board family:DDTB
-
Documented role:Auxiliary I/O terminal board
-
System context:LS2100 control cabinet
-
Visible test-point IDs:TP12, TP13, TP14 and TP15
-
Visible indicator IDs:DS9, DS10, DS11 and DS12
-
Board origin mark:U.S.A. printed on photographed PCB
-
Group:G2
Information
- As a terminal and interface assembly, the DDTB connects cabinet I/O to the configured control hardware. The functions of individual points depend on the host wiring and assigned terminal schedule; the board image alone does not establish signal ratings.
Cabinet: LS2100 family
Evidence: Complete G2ABB label photographed
As a terminal and interface assembly, the DDTB connects cabinet I/O to the configured control hardware. The functions of individual points depend on the host wiring and assigned terminal schedule; the board image alone does not establish signal ratings.
Before a replacement, compare the G2ABB execution, physical connectors and site terminal designations with the installed board. Restore the documented wiring and confirm the affected cabinet I/O under the approved commissioning sequence.
-
GE DS200DDTBG2ABB technical reference
2-page reference on auxiliary i/o terminal board, verified identification and installation planning. -
GE DS200DDTBG2ABB installation verification guide
1-page guide for identification, connection review, installation checks and handover evidence.
Terminal compatibility: G2ABB revision and each connected I/O point must match the cabinet terminal schedule.
-
LS2100 auxiliary I/O
Use within an LS2100 cabinet configured for the DDTB G2 board. -
Cabinet terminal interfaces
Match the existing connector and terminal map to the host wiring schedule. -
Control-system maintenance
Record as-found I/O and cable positions before replacement. -
Functional restoration
Verify every affected auxiliary signal after the board exchange.
Capture DS200DDTBG2ABB from the offered and installed labels.
Preserve the site terminal and cable schedule before removal.
Check pin condition and seating at mating interfaces.
Do not substitute another DDTB group without approved guidance.
Follow the LS2100 service procedure and ESD controls.
Test affected I/O indications and outputs after reassembly.
Alternative Names
Technical notes
Documented family: GE identifies DDTB as an auxiliary I/O terminal board.
Exact identity: The photographed board label reads DS200DDTBG2ABB.
System boundary: Individual terminal assignments depend on the installed LS2100 cabinet.
FAQ View All FAQ
-
What identifies the offered DS200DDTBG2ABB assembly?The photographed complete DS200DDTBG2ABB label and GE board marking identify this execution.
-
How are individual DS200DDTBG2ABB terminal functions established?Use the installed LS2100 wiring and I/O schedule, not a generic pin assumption.
-
Can another DDTB group replace DS200DDTBG2ABB?Only when the host design and approved manufacturer replacement guidance accept the different group.
-
What should be documented before removing DS200DDTBG2ABB?Capture cable tags, terminal positions, board revision and as-found I/O indications.
-
How is connector condition assessed for DS200DDTBG2ABB?Inspect contact plating, keying, alignment and retaining features.
-
What tests follow installation of DS200DDTBG2ABB?Exercise affected auxiliary inputs and outputs through the approved cabinet test procedure.
-
Does the photographed U.S.A. marking define each DS200DDTBG2ABB electrical rating?No. It is a visible board mark; electrical limits require the applicable instruction.
-
How should DS200DDTBG2ABB be handled outside the cabinet?Apply isolation and ESD handling and protect both edge and plug contacts.
Supporting new and legacy automation
-
Please try to be as accurate as possible with your search.
-
We can quote you on 1000s of specialist parts, even if they are not listed on our website.
-
We can't find any results for “”.
Related cases and sourcing guidance
View all case studiesYou May Also Like
Product Browsing History
-
Whatsapp: +86 18030235313
Send us a message. -
sales13@apterpower.com
Complete our online form. -
+86 18030235313
Speak to our team in your native language.